FLOS In-Finity General Lighting Dali Installation Guide

June 3, 2024
FLOS

FLOS In-Finity General Lighting Dali

INSTRUCTIONS OF INSTALLATION AND USE ATTENTION!

The safety of the device can only be guaranteed on condition that to be respected the following instructions, both stages of installation and use therefore it is highly recommended to keep them.

WARNING
To carry out the installation, and whenever an operation in the device is carried out, make sure of having disconnected the electric power. The device cannot be in any case modified or forced, any modification might jeopardize the safety system making it dangerous. FLOS declines any responsibility on modified products.
The device has been designed for inside.

IP20 Ordinary.

Luminaire kind I: In order lo obtain a safe and correct operation, ii is necessary that this device is connected to an efficient earth system.
Luminaires intended for direct assembly on surfaces that are normally flammable.

Under no circumstances should the luminaire be covered with insulating or similar material.

The symbol marked on the device indicates the replacement of the damaged protection screens using exclusively original FLOS spare parts. Do not use the luminaire without glass.

If the flexible cable or cord of this luminaire is damaged, it should be exclusively replaced by the manufacturer or his technical service or a qualified person in order to avoid any risk.

Use an appropriate equipment and in agreement with the standard.

TECHNICAL DATA

The symbol shown on the device indicates that the product must be eliminated differently from the rest of the urban waste.

CLEANING INSTRUCTIONS

Use only a soft cloth to clean the appliance, dampened with water and soap or mild cleanser if needed for resistant dirt.
Warning: do not use alcohol or other solvents.
The classification that has been maintained between the LV mains power g supply and the control conductors (DALI) is in main insulation.

ENDCAP INSTALLATION

LINER & CORNER ASSEBMLING









ELECTRICAL CONNECTION

GROUND


SAFETY SYSTEM

FEED CONNECTION




CORNER CONNECTION

LINER AND CORNER INTERCONNECTION



DIFUSSER

ACCESSORIES

LUMINAIRE INSTALLATION

Maximum number of LED modules / Drivers connected per MCB

MCB type

| Infinity 35&70|

Infinity 100

B13

|

17

|

12

C13

|

28

|

20

|

FOR UL PRODUCT
MAXIMUM OF 15 UNITS CONNECTED OR TOTAL INPUT LESS THAN 6AMPS

|
---|---|---

L

| A
(mm)| B
(mm)|

N° LED
Modules / Drivers

---|---|---|---
845| 785| 845| 1
1125| 1065| 1125| 1
1405| 1345| 1405| 1
1690| 1630| 1690| 2
1970| 1910| 1970| 2
2530| 2470| 2530| 2
3095| 3035| 3095| 3

ONE PROFILE

TWO PROFILE

MORE THAN THREE PROFILE

CORNER PROFILE


Calle Mallorca, 1
Poligono Industrial Reva
46394 Ribarroja
Valencia-Spain
Tel: +34 961 669 520
Fax: +34 961 668 286
www.flos.com

Documents / Resources

| FLOS In-Finity General Lighting Dali [pdf] Installation Guide
In-Finity General Lighting Dali, In-Finity, General Lighting Dali, Lighting Dali, General Dali
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals