FIELDMANN 7005-EC Submersible Garden Pump User Manual

July 26, 2024
FIELDMANN

FIELDMANN 7005-EC Submersible Garden Pump User Manual

Thank you for purchasing this pump. Before using it, please carefully read this User manual and keep it in a safe place for further use.

GENERAL SAFETY REGULATIONS

Important safety notice

  • Carefully unpack the product and take care not to throw away any part of the packaging until all the product parts have been identified.
  • Read all warnings and instructions. Not following warnings or instructions may lead to injury from an electric shock, fire and/or serious injuries.

ATTENTION! Protect yourself against electric shock!

Packaging

The device is contained in a package intended to prevent any damage during transport. This package is a resource and so it can be handed over for recycling.

User’s Manual

Before first using the pump, please read the following safety instructions and the User manual. Learn about all the parts and the correct use of the device. Keep the user’s manual in a safe place for easy future reference.
If giving the device to somebody else, do so together with the User manual. Following the instructions in the included User manual is a prerequisite for safe use of the garden appliance. The user’s manual also contains operating, maintenance, and repair instructions.

NOTE : If you hand over the appliance to somebody else, do so together with this user’s manual.Make sure you use the appliance properly by following the instructions in the included User manual. The user’s manual also contains operating, maintenance, and repair instructions.

Electrical Safety

The pump can be connected to any power plug installed according to the given norms.
The plug must be powered at 230V ~ 50Hz.

ATTENTION! Important for the protection of your personal safety. Before first starting your new submersible pump, have a professional check the following items:• Grounding

  • Neutral conductor
    The current circuit breaker must conform to energy safety norms and must fully function correctly.
    The electrical connection must be protected against moisture.
    If there is a risk of the electrical connection being flooded, it must be moved higher.

  • In all situations, prevent the circulation of aggressive liquids and coarse materials.
    The submersible pump must be protected against frost.
    The pump must be protected against running when empty.
    Prevent children from accessing parts of the pump by taking the appropriate measures.

The manufacturer will not accept any responsibility for accidents or damage resulting from not following the instructions in this manual.

DESCRIPTION OF THE MACHINE AND CONTENTS

Description of the machine (see Fig. 1.)

  1. Pump body
  2. Power cable
  3. Hose connection hole
  4. Float switch
  5. Eye for hanging the pump
  6. Threaded coupling
  7. Hose barb

OPERATING INSTRUCTIONS

Purpose of use

  • This pump is primarily designed for pumping service water from wells, rainwater tanks, manholes and for the operation of irrigation systems.

  • The appliance is intended for private household use and is not suitable for professional applications.

  • It is not suitable for work with waste water in sewage systems, salt water, aggressive or easily combustible
    substances, for work in food processing or as a pump for water jets on garden ponds.

  • It is not designed for pumping drinking water!

NOTE : Before using the submersible pump, please first carefully read all the safety instructions and instructions for use for the pump. Only after reading these instructions will you be able to safely and reliably use all the functions of the pump. You must conform to all local regulations in force in your country. These regulations are effective together with the particulars specified in these instructions.

ATTENTION! If you will be using the pump near pools or garden ponds, or in their protective zone, the electrical grid must be equipped with a circuit breaker.

The pump must not be used if there are people in the pool or garden pond! Also do not use it if there are fishes or other living creatures in the pool or garden pond.

The submersible pump is designed to pump water at a maximum temperature of 35°C.

The pump must not be used for other liquids, particularly motor oils, cleaning agents and other chemical products!

PUTTING INTO OPERATION

Connecting the hose

  • 1” and ¾” hose can be connected to the pump as standard. After cutting the hose barb, a ½” hose can also
    be connected using a ¾ screw union and a standard quick coupling

  • ¾” hose connection (Fig.2)

    Screw the threaded coupling into the pump (Fig. 2, point 1) and connect the hose barb (Fig. 2, point 2).
    The hose must be secured to the barb with a tightening strap (Fig. 2, point 3)

  • 1” hose connection (Fig.3)

    First, cut the ¾-hose connection from the hose barb.
    Screw the threaded coupling into the pump (Fig. 3, point 1) and connect the hose barb (Fig. 3, point 2).
    The hose must be secured to the barb with a tightening strap (Fig. 3, point 3)

  • ½” hose connection via quick coupling Screw the threaded coupling into the pump (Fig. 4, point 1 ) and connect the standard hose connection ( Fig. 4, point 2 ). You can then use a standard quick couplet **(Fig. 4, point 3)

**

Pump installation

  • always hang the pump on the eye on the top of the pump (Fig. 5, point 1). Always use a silk rope with the
    appropriate load capacity for hanging (Fig. 5, point 2)
    When installing at a depth greater than 5 m, secure the supply cable (Fig. 5, point 3) to the suspension rope
    with plastic tie straps.

ATTENTION! Never install the pump by hanging it on the outlet hose or power cord without additional support. For proper pump operation, the fluid must not contain any solid impurities

  • The pump must be submerged at least 150 mm below the surface and at the same time 30 cm above the
    bottom (Fig. 6)

  • The level at which the pump switches on and off can be set by fixing the float in the pump clip. (Fig. 7)

  • The pump can operate in manual mode, i.e. it does not switch off automatically. To do this, fix the float to the
    pump (Fig. 8)

    ATTENTION! The pump must not be dry operated.

ATTENTION! Risk of dry running – The pump is cooled using the pumped liquid. In the event of dry running, the pump motor may burn up.

MAINTENANCE AND STORAGE

This submersible pump is approved as a maintenance-free product undergoing several final inspections. We recommend you perform regular inspections and maintenance, which will ensure a long lifetime and continuous performance.

ATTENTION! Disconnect the power source before performing any maintenance.

Maintenance

  • If the pump is regularly moved during operation, it should be rinsed out after each use with clean water.

  • If the pump is permanently installed, the working order of the float switch should be checked every 3 months.

  • Any fibrous deposits that could deposit themselves inside the pump, should be removed using a water
    current.

  • If an excessive amount of debris accumulates in the body of the pump, flush the pump out with clean water.

  • The protective cover serving as a filter should be cleaned regularly (Fig. 9.)

Storage

  • Store the thoroughly cleaned out pump in a dry place out of children’s reach.

WHAT TO DO “WHEN…”

When… Causes Repairs
The pump does not start No power supply. Check the power supply.
The float won’t switch. Check if the float got stuck.
No flow The check valve is choked. Clean the check valve.
The pressure hose is bent. Straighten the hose.
The pump does not turn off The float cannot drop. Check if the float got

stuck.
Insufficient flow| The check valve is choked.| Clean the check valve.
Reduced pump capacity due to dirty and contaminated water.| Clean the pump and flush the hose with clean water.
The pump turns off after a short time| The temperature fuse stops the pump due to dirty water.| Disconnect the power plug. Clean the pump and the pumping pit.
The water is too hot. The temperature fuse stops the pump.| Check that the maximum water temperature of 35°C is not exceeded.

NOTE:
Not covered by the warranty:

  • Damage to the rotating mechanical gasket caused by running the pump empty, or by foreign objects in the water
  • Blocking the running of the wheel with foreign objects
  • Damage during transport
  • Damage caused by unprofessional alterations

TECHNICAL SPECIFICATIONS

| FVC 7005-EC
---|---
Voltage/Frequency| 230V ~ 50Hz
Input power| 1,200W
Maximum transferred amount| 6,200 l/h
Maximum delivery| 46m
Maximum temperature of the media| 35°C
Maximum pressure| 4.6 bar
Weight| 7.8 kg

DISPOSAL

INSTRUCTIONS AND INFORMATION ON DISPOSAL OF USED PACKAGING MATERIAL
Dispose of used packaging material at a site designated for waste in your municipality.

The appliance and its accessories are manufactured from various materials, e.g. metal and plastic. Take damaged parts to a recycling centre. Inquire at the relevant government department.

This product meets all the basic requirements of the applicable EU directives.

The text, design and technical specifications may be changed without prior notice and we reserve the right to make these changes.

User manual in the original language.

DECLARATION OF CONFORMITY

EU DECLARATION OF CONFORMITY
Product / brand: Submersible Pump / FIELDSMAN
Type / model: FVC 7005-EC as factory model EC-TDS 1200_I INOX

This declaration of conformity is issued under the sole responsibility of the manufacturer.
The object of the declaration described above is in conformity with the relevant Union harmonisation legislation:
Directive MD 2006/42/EC
Directive EMC 2014/30/EU
Directive RoHS 2011/65/EU+(EU)2015/863

The relevant harmonized standards and the other technical specifications:
EN 60335-1:2012+A11+A13+A1+A14+A2+A15
EN IEC 55014-1:2021
EN 60335-2-41:2003+A1+A2
EN IEC 55014-2:2021
EN 62233:2008
EN IEC 61000-3-2:2019+A1
EN ISO 12100:2010
EN 61000-3-3:2013+A1+A2

Place of issuance: Prague
Date of issuance : 05. 09. 2023

Name : Pete Her – Responsible Person
Signature

Documents / Resources

| FIELDMANN 7005-EC Submersible Garden Pump [pdf] User Manual
7005-EC Submersible Garden Pump, 7005-EC, Submersible Garden Pump, Garden Pump, Pump
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals