FLOS F4350030 Outdoor Wall-Ceiling Lights User Manual
- June 4, 2024
- FLOS
Table of Contents
FLOS F4350030 Outdoor Wall-Ceiling Lights
My Way 110×100 Black
■ F4350030 – Black
Luminaire for outdoor use for built-in installation on the wall with LED light
source.
Aluminum die-cast body EN AB-47100 (low copper content).
High-resistance coating: after a sandblasting treatment of all components to
make the surface porous and ensure a greater adhesion of the paint, the
external coating is applied with a double layer with epoxy powders according
to the QUALICOAT standard. The first layer of epoxy powder gives chemical and
mechanical resistance, the second finishing layer of polyester powder ensures
resistance to UV rays and atmospheric agents.
The painted surfaces are treated with alkaline and acidic washes, then rinsed
with demineralized water, subjected to a chemical conversion treatment to
protect against oxidation.
Frosted polycarbonate diffuser, UV-stabilised, glued to the head of the
product to ensure a watertight seal.
Integrated 110/240V power supply. Supplied with a 120 mm lenght outgoing
neoprene cable and IP67 cable connection system.
Dimmable version on request
Main specifications
Lamp category | LED |
---|---|
Power (W) | 5 |
CCT (K) | 2700K |
CRI | 80 |
Net lumen (lm) | 188 |
Mountings | Wall recessed |
Environment | Outdoor wet location |
Optical
Lighting type | Direct |
---|---|
LED type | Power LED |
Light distribution | Asymmetric |
Optical type | Asymmetric |
Beam angle (°) | 50 |
Beam angle C90-270 (°) | 74 |
Electrical
Frequency (Hz) | 50-60 |
---|---|
Voltage (V) | 100-240 |
Dimmable | Yes |
Driver | Integrated |
Driver type | Non Dimmable |
Emergency | Without |
Insulation class | I |
Physical
Color | Black |
---|---|
Orientation | Fixed |
Weight (kg) | 0.52 |
Note
We recommend using a connection system with a degree of protection greater
than or equal to the degree of protection of the luminaire.
During the installation and the maintenance of the fixtures it is important to
be careful and avoid damages on the paint coating.
Damages on the coating exposed to outdoor conditions or water, could cause
corrosion.
Chemical substances affect the anticorrosion covering protection.
For LED fixtures, there is evidence that most of the damages are connected to
electrical effects related to the insulations, which cause destructive
electrical discharges
These effects are frequently caused by:
• over voltage coming from the mains’ network where fixture is connected.
• electrostatic discharge (ESD) coming from the environment.
The use of a protective device against the overvoltage on the electrical
installation is warmly suggest this helps to reduce the intensity of some of
these phenomenon and prevent irreversible damages. The selection of the type
of device to be used must be adjust on the electrical plant.
| |
---|---|---
S.P.D. (SURGE PROTECTION DEVICE) F990E00A000| 2 way terminal block 4 poles
IP68 H20 stop. (ø5,5÷12mm cable) F990C00A000| Box for installation F4301000
https://www.flos.com/professional-space/outdoor/products/my-
way-110×100-black-f4350030/
www.flos.com – flos.outdoor@flos.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>