ELKO RF Touch-2-BE Wireless Touch Unit Instruction Manual

July 9, 2024
ELKO

ELKO RF Touch-2-BE Wireless Touch Unit

FAQ

Frequently Asked Questions

  • How do I change the Wi-Fi network on the RF Touch unit?
    • To change the Wi-Fi network, go to Wi-Fi settings in the unit’s menu and follow the steps outlined in the manual.
  • Can I use the RF Touch unit without connecting it to a Wi-Fi network?
    • Yes, if you wish to use the unit only locally with limited features, you can choose not to connect to a Wi-Fi network and follow the instructions provided in the manual.

Characteristics

  • RF Touch-2 touch control unit is a system element used for automatic and manual control of switching, dimming, or blind elements and heating control elements within the iNELS Wireless system.
  • The control unit is available in two versions:
    • RF Touch-2/BE – professional version powered via PoE, USB-C, or 10-30V DC screwless terminals and communicating via Wi-Fi and LAN for connection in new home installations, hotels, hospitals, and of buildings
    • RF Touch-2/BR – simpler version with powered via USB-C or 10-30V screwless terminals and communicating via Wi-Fi for easy connection in renovated rooms without having to connect to the local network
  • Both versions communicate wirelessly with iNELS Wireless units using radio frequency and allow up to 40 wireless element addresses and 30 detectors to be connected in this way.
  • RF Touch-2 touch unit also serves as a communication gateway, so besides direct control via the 4“ capacitive display, it allows communication with the system via the iNELS app and provides connection to the iNELS Cloud.
  • RT Touch-2 unit off ers a range of automatic functions that can be used even when not connected to a local network, such as controlling heating modes, timers, light scenes, and leaving buttons.
  • RF Touch-2 features integrated temperature and humidity sensors for controlling heating modes.
  • Innovative design allows for easy installation in a mounting box

Connection

Connect the RF Touch unit to the power supply.

You can use one of 3 ways:

  • LAN cable for Ethernet communication and passive PoE power supply (only available with RF Touch-2/BE version)
  • Power supply via 10-30V DC screwless terminals
  • 5V power supply via USB-C
  1. On the screen that appears after you plug it in for the first time, press the START WITH SETTINGS button, which will take you to the unit settings menu.
  2. Select the menu language (1) and press the continue button (2)
  3. Press YES to connect the unit to a Wi-Fi network. This will make setting up your device easier.
    • If you have the RF Touch-2/BE version and you wish to communicate with the unit over a local network, press NO and follow the procedure under part 9 of this manual.
    • If you wish to use the unit only locally with limited features, press NO and follow part 8 of this manual
  4. Press Enable Wi-Fi, activate Mode: Client and go to Connection Settings.
  5. Select an available Wi-Fi network, enter the password and press SAVE to confirm.
  6. Press the button to go BACK and press CONTINUE
  7. You are now in the default menu of the unit.
    • You may continue with the complete setup of the device via the iNELS mobile app (all changes made in the mobile app will reflect automatically in the control menu of the device). See instructions regarding setting up the mobile app: https://www.elkoep.cz/media/import/Elko/iNELS%20app/CS/Manual_iHC–AIO_cz.pdf
    • You can continue with manual setup of the device. Press the cogwheel to access the Settings menu. You can check the network connection and the local address of the unit by pressing the overview, or continue to the Settings menu. Enter the PIN code to enter the manual settings of the unit. The PIN code is preset to 1111.
  8. Adding rooms
    • In the Rooms menu, you can add control areas to your building and then assign selected devices to them. To create a new room, press the + button.
    • In the following menu, you can enter the room name and assign a selected icon to it.
  9. Adding devices
    • In the Devices menu you can add elements (switches, dimmers, blinds…) that will control the appliances in your home. To create a new device, press the + button.
    • To add an element, enter its name (1), address (2) – an 8-digit number printed on the device body, the device type (3), such as RFSAI-61B-SL switch, assign an icon to the device and press SAVE.
  10. Display settings
  11. Move your finger to the right or left, the display brightness level in percentage in active mode
  12. Move your finger to the right or left, you can set the display brightness level in percentages in power-saving mode
  13. Move your finger to the right or left to set the time in seconds for the display to switch from active to saving mode
  14. Wi-Fi settings
    • Here you can change your Wi-Fi settings at any time.
    • The procedure is described in parts 5 through 7 of this manual

Communication diagram

Communication with RF Touch-2/B can be direct (fixed IP) or indirect (via iNELS cloud).

More detailed information can be found in the iNELS RF Control Installation Manual: https://www.elkoep.com/catalogs-and-brochures
ELKO EP, sro hereby declares that the type equipment RF Touch-2/BE, RF Touch-2/BR is in accordance with Directives 2014/53 / EU, 2011/65 / EU, 2015/863 / EU and 2014 / 35 / EU. The full text of the EU Declaration of Conformity is available on the following websites: https://www.elkoep.com /wireless-touch-unit—rf-touch-2b

Safe handling

  • When handling a device unboxed it is important to avoid contact with liquids. Never place the device on the conductive pads or objects, avoid unnecessary contact with the components of the device.

Technical Parameters

RF Touch-2/BE  | RF Touch-2/BR

Display

Type: color TFT LCD 4“
Distinction: 480 x 480 pixels
Aspect Ratio: 72 x 72 mm
Visible area: active (white LED)
Backlight: capacitive

Power supply

USB-C 5V 5V
Passive PoE: 24V
Terminal plate: (10-30V DC)
Power consumption: max. 3 W

Communication

Radio|
---|---
Communication protocol:| RFIO2
Frequency:| 866–922 MHz
Range:| open space up to 200 m
Min. distance RF Touch component:| ****

1 m

WiFi|
Protocols:| 802.11 b/g/n (802.11n to 150 Mbps)

A-MPDU and A-MSDU

Frequency:| 2.4 GHz
LAN|
Ethernet:| 100 Mbit/s| —

Sensors and notifications

Temperature sensor 0-50 ° C; 0.2 ° C out of range
Humidity sensor 0-100%; 2% of range (RH)
Proximity sensor 15cm
Notification LED RGB

Operating conditions

Operating temperature: 0 to +50 °C
Storage temperature: – 20 to +70 °C
Cover: IP20
Surge category: III.
Degree of pollution: 2
Working position: any
Installation: into the installation box
Dimensions: 86 x 86 x 10 (37)
Weight (plastic): 120 g
Related standards: EN 60730, EN 63044, EN 300 220, EN 301 489, EN 300 328

Warning

Instruction manual is designated for mounting and also for user of the device. It is always a part of its packing. Installation and connection can be carried out only by a person with adequate professional qualifications upon understanding this instruction manual and functions of the device, and while observing all valid regulations. The trouble-free function of the device also depends on transportation, storage and handling. In case you notice any sign of damage, deformation, malfunction or missing part, do not install this device and return it to its seller. It is necessary to treat this product and its parts as electronic waste after its lifetime is terminated.

Before starting installation, make sure that all wires, connected parts or terminals are de-energized. While mounting and servicing observe safety regulations, norms, directives and professional, and export regulations for working with electrical devices. Do not touch parts of the device that are energized – life threat. Due to the transmissivity of RF signal, observe correct location of RF components in a building where the installation is taking place. RF Control is designated only for mounting in interiors. The must not be installed into metal switchboards and into plastic switchboards with metal door – transmissivity of RF signal is then impossible. RF Control is not recommended for pulleys etc. – the radiofrequency signal can be shielded by an obstruction, interfered, battery of the transceiver can get flat etc. and thus disable the remote control.

Contact

ELKO EP, s.r.o.

Made in Czech Republic

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals