LEDone T8 Tube Series Ballast Compatible Lamps Instructions

June 3, 2024
LEDone

LEDone T8 Tube Series Ballast Compatible Lamps Instructions

LEDone T8 Tube Series Ballast Compatible Lamps

The T8 LED tube cannot be installed in rain, wet areas, dusty areas, flammable areas or combustible environments. Please confirm  the light fixture meets the level of protection requirements if necessary.

IMPORTANT

READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. LEDONE tubes must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TNv/ technician for help.

WARNING:

  1. LED Luminaire Retrofit Kit Including LED Tube, Installation instructions,Luminaire Marking Label.

  2. Risk of fire or electric shock. LED Retrofit Kit installation requires knowledge of luminaires electrical systems. If not qualified,  do not attempt installation. Contact a qualified electrician in accordance with the National Electrical Code and relevant local  code. 0-10V I Phase cut dimming with specified dimmers only.

  3. Risk of fire or electric shock. Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings and where the input rating of the retrofit kit does not exceed the input rating of the luminaire.

  4. To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation. This device is not intended for use with emergency exits. This item is rated at 120-277V. Installer must determine whether line voltage 120-277V is available at the luminaire before installation. SUITABLE FOR DAMP LOCATIONS.

  5. Installers should not disconnect existing wires from lampholder terminals to make new connections at lampholder terminals. Instead installers should cut existing lampholder leads away from the lampholder and make new electrical connections to lampholder lead wires by employing applicable connectors.

  6. THIS RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL
    BE DETERMINED BY AUTHORITIES HAVING JURISDICTION.

  7. To avoid potential fire or shock hazard, do not use this retrofit kit in luminaires employing shunted bi-pin lampholders. Note: Shunted lamp holders are found only in fluorescent luminaires with Instant-Start ballasts. Instant-start ballasts can be identified by the words “Instant Start” or “I.S.” marked on the ballast. This designation may be in the form of a statement pertaining to the ballast itself, or may be combined with the marking for the lamps with which the ballast is intended to be used, for example F40T12/1S. For more information, contact the LED luminaire retrofit kit manufacturer.

INSTALLATION INSTRUCTIONS-Ballast Compatible

FIG 1 INSTALLATION INSTRUCTIONS-Ballast Compatible

PRODUCT NOTES

The products are intended to retrofit type IC or Non-IC recessed mount listed fluorescent luminaires with instructions to remove the existing trim. Use maximum four straight tubular lamps with or without a diffuser.

INSTALLATION INSTRUCTIONS-Ballast Bypass DOUBLE-ENDED POWER

  1. Make sure the circuit breaker that supplies the power to the fixture is turned off.
  2. Remove lens or diffuser cover (if applicable) and existing  fluorescent lamps.
  3. Open/Remove ballast wiring compartment cover.
  4. Identify the line and neutral wires running from the breaker box to the ballast and confirm the power is off using a voltmeter.
  5. Cut all wires connected to ballast,
  6. Dispose of removed ballast and fluorescent lamps in accordance with government regulations in your area.
  7. Ensure that the fixture contains shunted Gl 3 bi-pin lamp holders. If socket lamp holders are non-shunted, replace with new shunted socket lamp holders, or shunted with a jumper wire to convert into shunted sockets.
  8. LED T8 lamps are designed for double sided connections only (Fig. 1). To install, please wire non-shunted sockets by connecting one wire from the lamp holder to branch circuit L (LIVE) and the other wire at the opposite end to branch circuit N (NEUTRAL). Do not connect opposite side to power. Use appropriate wires for connection.

FIG 2 INSTALLATION INSTRUCTIONS

8. Make sure a I sockets are replaced and wired according to the appropriate wiring diagram. (Fig. 2,

FIG 3 INSTALLATION INSTRUCTIONS

FIG 4 INSTALLATION INSTRUCTIONS

FIG 5 INSTALLATION INSTRUCTIONS

FIG 6 INSTALLATION INSTRUCTIONS

9. Reinstall the ballast cover to hide all wires.
10. Install your new LEDT8 replacement lamps.
11. Apply Relamping Label on a visible location inside the fixture.
12. Reinstall lens or diffusion cover on the light fixture.
13. Turn power on at the breaker box.
14. Turn on the lights.

Note: These instructions do not coverall details or variations in equipment nordo they provide for every possible situation during installation, operation or maintenance.

INSTALLATION INSTRUCTIONS-Ba last Bypass SINGLE-ENDED POWER

  1. Turn Power OFF.
  2. If applicable, replace lamp holders at power end with non-shunted lamp holders (Fig.6).

FIG 7 INSTALLATION INSTRUCTIONS-

FIG 8 INSTALLATION INSTRUCTIONS-

Read More About This Manual & Download PDF:

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

LEDone User Manuals

Related Manuals