AViANCE Lighting HD68605 Fixture Installation Guide

July 4, 2024
AViANCE lighting

AViANCE Lighting HD68605 Fixture

Product Specifications

  • Model: HD68605
  • Fixture Type: Ceiling Light Fixture
  • Power Requirement: Standard household voltage
  • Maximum Wattage: Refer to fixture specifications
  • Wiring Requirements: Black, White, Bare Copper

Product Usage Instructions

  • Place the candle sleeve over the lamp holder.
  • Install light bulbs (not included) according to the fixture specifications.

NOTE: Ensure not to exceed the specified wattage for the bulbs.

  • Turn off the power at the circuit breaker and remove the old fixture from the ceiling.
  • Connect the black wire from the ceiling junction box to the smooth wire leg from the fixture.
  • Connect the white or ribbed wire from the fixture to the white (neutral) wire in the house wiring.
  • Connect the bare copper wire from the fixture to either the green or bare copper wire in the house wiring (ground).

Your installation is now complete. Restore power to the junction box and test the fixture for proper functionality.

FAQ

  • Q: What should I do if the fixture does not turn on after installation?
  • A: Check the connections of the wires to ensure they are secure and correctly matched. Verify that the power source is active.
  • Q: Can I use bulbs with a wattage higher than the specified limit?
  • A: It is not recommended to exceed the specified wattage as it may lead to overheating and potential hazards. Stick to the recommended wattage for safe operation.

Thank you for choosing AVIANCE products. For further assistance with parts or assembly, please contact customer service at info@aviancelighting.net.

ASSEMBLING & INSTALLATION INSTRUCTIONS

  • The drawing shown may not exactly match the product enclosed.
  • However, the installation instructions do apply to this product.
  • WARNING! SHUT THE POWER OFF AT THE FUSE OR CIRCUIT BREAKER.
  • ATTENTION! COUPER LE COURANT AU FUSIBLE OU UN DISJONCTEUR.

ASSEMBLING THE FIXTURE (Fig.2)

  1. Put the candle sleeve over the lamp holder.

  2. Install the light bulbs(Not included) according to the fixture specifications.
    NOTE: DO NOT EXCEED THE SPECIFIED WATTAGE!
    HANGING THE FIXTURE (Fig.1)

  3. Shut off the power at the circuit breaker and remove the old fixture from the ceiling, including the old single bar. Shut off the power at the circuit breaker and remove the old fixture from the ceiling, including the old single bar.

  4. Carefully unpack the new fixture and lay all the parts on a clear surface.

  5. Thread nipple (C) into loop (F) until snug.

  6. Thread the other end of the nipple (C) with a loop attached to a single bar (D) until snug.

  7. Place lock washer (B) over the end of nipple protruding through single bar and thread hex nut (A) onto nipple until tight.

  8. Take this single bar assembly and mount it to the ceiling junction box with junction box screws (E). Tighten screws securely with screwdriver.

  9. Use proper chain pliers to open one end link of the chain provided and connect to the fixture loop. Close the link.

  10. By measuring, determine the correct number of links needed for proper hanging height. Using proper chain pliers disconnect and discard the remaining chain.

  11. Lace the fixture wires through the chain.

  12. Slip the loop collar (H) over the chain, then do the same with the canopy (G).

  13. Open the other end link of the chain and hang the fixture on the loop at the ceiling. Close the link.

  14. Feed the fixture wires through the loop (F) and nipple (C) and pull until taut.

CONNECTING THE WIRES

  1. Take the black wire from the ceiling junction box and the smooth wire leg from the fixture and twist the bare ends together. Twist wire connector onto the end of the wire until snug.
  2. Repeat the same process with white junction box wire and ribbed wire leg of fixture wire. NOTE: Twist wires together in the same direction you twist the wire connector onto wires.
  3. If your junction box has a grounding wire (green or bare copper), attach this wire and the bare copper wire from the fixture together as in step 1. If the junction box has no ground wire, attach the bare copper fixture wire to the green ground screw on the crossbar.
  4. Tuck these wire connections neatly into the ceiling outlet box and then raise the canopy (G) to the ceiling. Raise the loop (H) and thread it onto the ceiling loop protruding through the canopy.

Your installation is now complete. Return power to the junction box and test the fixture.

Thank you for purchasing an AVIANCE product.