TELTONIKA FMB641 Thermograph 2G Tracker Instructions

June 27, 2024
teltonika

TELTONIKA FMB641 Thermograph 2G Tracker

Specifications

  • Product Name: FMB641 Thermograph
  • Supported Thermographs: Euroscan, DataCold600, Transcan2, TouchPrint
  • Interface: RS-232
  • Communication: Full-duplex

Introduction
With an increasing demand for cold-chain supply chains, Teltonika is offering the ability to monitor real-time information from freezer trailer thermographs. Each thermograph has an RS232 communication line where FMB641 devices can connect via COM1/COM2 port of the device. The  solution is easy to install and configure. This allows you to monitor the main information of thefreezer trailer such as Temperature, Fridge door status, Alarms, etc., and generate events according to your needs. For more information please refer to the installation manual below.

NOTE: t his feature is available from FW ver. 01.02.23.Rev.00

Product Usage Instructions

Installation Guide:

  • Connect the FMB641 to the desired thermograph using the appropriate RS-232 interface.

TELTONIKA FMB641 Thermograph 2G Tracker

  • TouchPrint/TouchLog: No configuration needed. Refer to ThermoKing Configuration for details.

  • FMB641 can be connected to Euroscan, DataCold600, Transcan2, TouchPrint thermographs.
    Refer to the table below to see which freezers use which thermograph:

    • Thermograph Type
      Freezer Type Euroscan DataCold600 Transcan2 TouchPrint/TouchLog

    • Carrier                    +                   +              –                  –

    • ThermoKing          +                   –               +                +

  • Carrier Datacold 600:

1. Select DataCold mode and set Baudrate to 38400 in FMX640 RS232 settings.
2. Enable Partner mode on DataCold 600 by following the specified steps.
3. Ensure RX and TX are inverted via the RS-232 connection.
  • Euroscan IO, TK Transcan2 Reefer, TK
    Touchprint/Touchlog I/O:
    Specific configurations may be required based on the user manual.

RS-232 Interface
RS-232 supports full-duplex communication which means the data can be both sent and received at the same time as they use separate transmission lines. Most of the modes are the same as for FMB641. When entering Sleep or Deep sleep RS-232 will be powered off. FMB641 RS-232
connection diagram is shown in the figure below:

TouchPrint/TouchLog

TouchPrint pinout:

No configuration is necessary.

If the equipment does not receive information from the thermographer, the speed of the port accessing the configuration menu:
Keep the blue and red buttons pressed at the same time. “Enter PIN code” is displayed on the screen, enter pin “1111” by pressing the blue button four times. Travel for the options with the red button. The ENG Display> OFF option must be ON, change its value with the keys ◄ and ►. Once switched to ON, keep scrolling through the options until you find Baud Rate> 9600. The value should be 9600, otherwise, adjust the speed by moving the cursor with the ◄ and ► keys, and adjust the speed with the keys ▲ and ▼.

TouchLog pinout:

AVL IDs for Touchprint:

  • Parameter name: AVL ID
    • Input 1: AVL ID 10695
    • Input 2 : 10696
    • Input 3: 10697
    • Input 4: 10698
    • Input 5: 10699
    • Input 6 : 10700
    • Setpoint 1: 10701
    • Setpoint 2: 10702
    • Setpoint 3: 10703

Configuration: No configuration is necessary.
See ThermoKing Configuration.

Carrier Datacold 600
To properly use DataCold 600 with FMX640 these steps must be followed:

  • In FMX640 RS232 settings DataCold mode is selected and Baudrate set to 38400
  • Partner mode enabled on DataCold 600

To enable Partner mode on DataCold 600:

  1. Press and hold the green button for 4 seconds
  2. Insert password. Default password – 1111
  3. Press the blue button to open 11 communication settings
  4. Press the green button to select edit action
  5. 11.1.0 Com1 Port settings should be opened, then press the green button again
  6. Then search for Partner protocol and press the green button to accept changes

Important note – RX and TX are inverted via the RS-232 connection. Scheme to properly manage
DataCold 600 RS232 connection: Pinout of DataCold600

Available parameters (AVL IDs) with DataCold 600:

Run mode explanation:

  • Run mode       StartStop Continious CycleCentry Unknown/Now available
    Value (HEX)            0              1                      2 7

Fuel and Battery state flag explanation:

  • Fuel/Battery Flag Status Available Error Alarm Digital sensor
    Enum (bit field) value            0            1           2              3

Euroscan
To properly use Euroscan with FMX640 these steps must be followed:

  • In FMX640 RS232 settings Euroscan mode is selected and Baudrate set to 38400
  • Partner mode enabled on Euroscan

To enable Partner mode on Euroscan :

  1. Press and hold the green button for 4 seconds
  2. Insert password. Default password – 1111
  3. Press the blue button to open 11 communication settings
  4. Press the green button to select edit action
  5. 11.1.0 Com1 Port settings should be opened, then press the green button again
  6. Then search for Partner protocol and press the green button to accept changes

Important note – RX and TX are inverted via the RS-232 connection. Scheme to properly manage
Euroscan RS232 connection: Pinout of DataCold600

Available parameters (AVL IDs) with Euroscan :

Configuration
Make sure the FMB641 device is configured to receive data from “Transcan2 Reefer”, “Touchprint Reefer”, “Euroscan: or “DataCold Reefer”. To do this, enter the configurator window, select the RS232 \ RS485 section displayed in the screenshots below, and configure accordingly (COM1/COM2 Settings, Mode “Transcan2 Reefer”, “Touchprint Reefer”, “Euroscan”or “DataCold Reefer”, Baudrate: Default)

DataCold Reefer
To configure “DataCold Reefer” I/O parameters, please select “Reefer IO”: Data sending parameters (AVL ID) used for “DataCold Reefer” are these: 10040 – 10649. For more in-depth information, please refer to Reefer IO data sending parameters.

TK Transcan2 Reefer
To configure “Transcan2 Reefer” I/O parameters, please select “TK Transcom IO”: Data sending parameters (AVL ID) used for “Transcan2 ” are these: 10683 – 10694. For more in-depth information, please refer to Transcan IO data sending parameters

Euroscan IO
To configure “Euroscan refeer” I/O parameters select “Euroscan IO”: Data sending parameters (AVL ID) used for “Euroscan” are these: 484-489 and 10464-10467. For more in-depth information, please refer to Euroscan IO data sending parameters.

TK Touchprint/Touchlog I/O
To configure “Touchprint Reefer” I/O parameters select “TK Touchprint IO”: Data sending parameters (AVL ID) used for “Touchprint Reefer” are these: 10695 – 10703. For more in-depth information, please refer to Touchprint IO data sending parameters.

Codec 8 Extended should be selected as the main data protocol in the “Protocol Settings” tab, which is located in the “System” section.

https://wiki.teltonika-gps.com/view/FMB641_Thermograph

Main Page > Professional Trackers > FMB641 > FMB641 Manual > FMB641 Thermograph

FAQ

Q: How do I know if my thermograph is supported by FMB641?
A: Refer to the table in the user manual to check compatibility with Euroscan, DataCold600, Transcan2, and TouchPrint thermographs.

Q: What is the communication interface used by FMB641?
A: FMB641 uses an RS-232 interface that supports full-duplex communication.

Read User Manual Online (PDF format)