DINSTAR UC350 Best Price In Bengaluru Installation Guide

June 26, 2024
DINSTAR

DINSTAR UC350 Best Price In Bengaluru

DINSTAR-UC350-Best-Price-In-Bengaluru-product

Specifications

  • Models : UC350, UC350 Pro
  • Interfaces:
    • UC350 : 2Network Ports, 1USB 2.0 Port, 1*Console Port
    • UC350 Pro: 4Network Ports, 2USB 2.0 Ports, 1USB 3.0 Port, 1Console Port, 1*HDMI Port
    • User Board Options : FXS, FXO, FXU, DTU

Product Usage Instructions

Installation

Installation Attentions:

  • The adapter of the gateway accepts DC220V 10A dual power input. Ensure it is workable and safe.
  • To reduce interference to telephone calls, separate power supply cables from telephone lines.
  • Ensure sufficient network bandwidth for normal gateway operation.
  • Place the gateway on a level surface with space for heat dissipation.

Installation Steps:

  1. Connect the power input to the gateway.
  2. Connect the grounding lug to ensure safe operation.
  3. Connect the telephone line to the FXS port and the PSTN line to the FXO port using appropriate converters.

Indicators and Ports
Refer to the user manual for detailed information on indicators and ports for both UC350 and UC350 Pro models.

Troubleshooting “
If you encounter any issues during installation or operation, refer to the troubleshooting section of the user manual or contact customer support for assistance.

THANKS FOR CHOOSING DINSTAR’S PRODUCTS!
Please read this guide carefully before installing the device. If you need any technical support, Please contact us

Models and Interfaces

| MCU Board| User board

(FXO, FXS, FXU, DTU)

---|---|---

UC350

|

2Network Ports 1USB 2.0 Port 1*Console Port

|

FXS Board: 2RJ45 with 8 FXS FXO Board: 2RJ45 with 8 FXO

| | FXU Board: 2*RJ45 with 4 FXS and 4 FXO
|

UC350 Pro

| 4Network Ports 2USB 2.0 Ports

1USB 3.0 Port 1Console Port 1*HDMI Port

| DTU Board: 4*RJ45 with 4 E1/T1 Ports

Description of Indicators

Type Indicators Definition Status Description

MCU

board

|

PWR

|

Power Indicator

| OFF| There is no power supply or the power supply is abnormal
ON| The device is powered on

RUN

|

Running Indicator

| Flashing| The device is initialized successfully and running normally
ON| The system is initializing
OFF| The device is not running normally

FXS/FXO/ FXU

User Board

|

PWR

|

Power Indicator

| ON| The power supply is normal
OFF| The power supply is not normal

RUN

|

Running Indicator

| Fast Flashing| The system is starting up
Slow Flashing| Part of the port registered successfully

FXS/FXO

|

FXS/FXO

Indicator

| ON| The FXS port is in off-hook (in-use) status
OFF| The FXS port is in on-hook status

DTU

User Board

|

PWR

| Power Indicator| OFF| There is no power supply or the power supply is abnormal
ON| The device is powered on

RUN

|

Running Indicator

| Slow Flashing| The device is initialized successfully and running normally
ON| The system is initializing
| | OFF| The device is not running normally
|

E1/T1

|

E1/T1

Indicator

| ON| E1/T1 line is connected
---|---|---|---|---
OFF| E1/T1 line is disconnected

Indicators and Ports

DINSTAR-UC350-Best-Price-In-Bengaluru-fig- \(1\)DINSTAR-UC350-Best-Price-In-Bengaluru-fig- \(2\)

Installation Attentions

  • The adapter of the gateway accepts DC220V 10A dual power input. Please ensure it is workable and safe.
  • To reduce the interference to telephone calls, please separate power supply cables from telephone lines.
  • To guarantee running of the gateway as usual, please make sure that there  is sufficient network bandwidth.
  • For better heat dissipation, please place the gateway on a level surface and  ensure space for other devices.

Installation Instructions

DINSTAR-UC350-Best-Price-In-Bengaluru-fig- \(3\)DINSTAR-UC350-Best-Price-In-Bengaluru-fig- \(4\)

  • Connect with Power Input
  • Connect with Grounding Lug
  • Connect telephone line to the FXS port and connect PSTN line to the FXO port
  • Connect to E1/T1 Ports
  • Connect to FXS ports and FXO ports
  • Connect with Ethernet

Note : The UC350’s default network port for management is the GE1 port, and the UC350 Pro’s default network port for management is the GE3 port.

RJ45 Wire Sequence

UC350 series products support RJ45 Interfaces for FXS/FXO connections. One RJ45 cable can be split into four pairs of RJ11 interfaces. The outlook wire sequence of RJ45 cable is shown as follows:

DINSTAR-UC350-Best-Price-In-Bengaluru-fig- \(5\)

Modify PC’s IP Address

To log in to the Web Management System of the device, firstly, you need to modify the IP address of the PC that is used to access the device and to make it at the same network segment as the device’s network port of management.

  1. On the PC, click ‘Network (or Ethernet) Properties
  2. Double-click ‘Internet Protocol Version 4 (TCP/IPv4)DINSTAR-UC350-Best-Price-In-Bengaluru-fig- \(6\)
  3. Select ‘Use the following IP address’, and then enter an available IP address ‘192.168.11.XXX’ which is at the same network segment with ‘192.168.11.1’.

DINSTAR-UC350-Best-Price-In-Bengaluru-fig- \(7\)

Login Web GUI

Open a browser and enter the default IP address of the network port for management: https://192.168.11.1. Enter the username and password to log into the system. The username and password are admin/admin@123#.

Note : The UC350’s default network port for management is the GE1 port, and the UC350 Pro’s default network port for management is the GE3 port. New devices can only modify the IP address through the management port. The UC350

The pro login interface is shown below:

DINSTAR-UC350-Best-Price-In-Bengaluru-fig- \(8\)

Check Network Status

Check the network status on the “System->Network” page.

DINSTAR-UC350-Best-Price-In-Bengaluru-fig- \(9\)

Modify Network Configuration

You need to modify the IP address of the network ports for service so that the ports and the upstream network are in the same network segment.
Firstly, you need to physically connect the device’s network port for management. Then log into the device by entering the IP address of the network port for management in the web browser and click “System->Network” to configure the IP address of the network ports for service. Click “Save” and “Reset” to make the settings take effect.

DINSTAR-UC350-Best-Price-In-Bengaluru-fig- \(10\)

Create SIP Extensions

Click “Extension & Call Group->SIP Extension” to create the SIP extension: add/delete/disable/enable, etc. UC350 Pro supports batch add or import account files.

Note : when add the extension, the profile should be chosen as the corresponding one.

DINSTAR-UC350-Best-Price-In-Bengaluru-fig- \(11\)

  • After setting, you need to click “apply” to make the settings take effect.
  • The registration status of SIP extension can be checked on the “Extension & Call Group->SIP Extension->Status” page.
  • If the status of a newly added SIP account is “registered”, it means that the device accepts the registration of the extension.
  • If the status of the SIP account is “unregistered”, it means that the device rejects to register the extension.

Add Trunk

SIP Trunk
SIP trunks are used to connect other SIP terminals or service providers. When adding a SIP trunk, you should choose corresponding SIP profile based on your current network. The SIP trunk supports UDP/TCP/TLS. You can create a new SIP trunk on the “Trunk & Route->SIP Trunk->Setting” interface, and SIP trunk status can be checked under “Trunk & Route->SIP Trunk->Status” interface.

DINSTAR-UC350-Best-Price-In-Bengaluru-fig- \(12\)

FXO
You can also create Trunk/FXO. It is an alternative to support calls go through or from PSTN.

DINSTAR-UC350-Best-Price-In-Bengaluru-fig- \(13\)

E1/T1
You can set up ISDN PRI/SS7 connections via digital E1/T1 ports. Please be sure that the E1/T1 physical connection is well connected, and PRI status is in up and active status before configuring the call routing.

DINSTAR-UC350-Best-Price-In-Bengaluru-fig- \(14\)

Configure Inbound / Outbound Route

On the “Trunk & Route->Route” interface, you can configure routes for incoming calls and outgoing calls, and select the call Source and Destination addresses for the route. When the configured route is activated, the system will match the route based on the priority index. The key configuration of route is at “condition” part. Here, you can configure the route based on the Caller/Called Number prefix and time.

DINSTAR-UC350-Best-Price-In-Bengaluru-fig- \(15\)

Regular Expression

Caller/Called number prefix supports regular expression Regular Expression Syntax

DINSTAR-UC350-Best-Price-In-Bengaluru-fig- \(16\)

Examples of Regex Syntax:

DINSTAR-UC350-Best-Price-In-Bengaluru-fig- \(17\)

Basic Operation

*Dial 114# to query the telephone number of a FXS port; Restart the device:**

  • Dial *111# to restart the device;
  • Click “system->Reboot” menu to perform reboot.

More Details
This document only provides instructions for quick installation and basic configuration. For detailed configuration and parameter explanations, Please refer to User Manual or ask for technical support.

IP COMMUNICATION SOLUTIONS

FAQ

Q: What should I do if the power indicator is not turning on?
A: Check the power supply connection and ensure that the gateway is receiving adequate power input. If the issue persists, contact customer support for further assistance.

Q: How can I expand E1/T1/FXS/FXO ports on the device?
A: Refer to the user manual for instructions on expanding ports using user board slots. Ensure proper installation to avoid any damage to the device.