DINSTAR UC120-1V1S1O Wireless USB GSM 4G VoLTE IP PBX Voip SIP Server with Wifi Router Installation Guide

June 11, 2024
DINSTAR

DINSTAR UC120-1V1S1O Wireless USB GSM 4G VoLTE IP PBX Voip SIP Server

with Wifi Router

Product Information

The Dinstar VoIP Gateway models UC120-1V1S1O, UC120-1V2S, UC120-1V2O, UC120-1S1O, UC120-2S and UC120-2O are available. These models have different interfaces and indicators depending on the specific model. The device comes with a power jack, WAN and LAN ports, FXS and FXO ports, LTE antenna, SD and SIM card slots, and a WiFi antenna. The device has indicators for power, running status, FXS and FXO port usage, network link, WiFi enable/disable, and LTE status.

Product Usage Instructions

  1. Before installing the gateway, carefully read the Quick Installation Guide provided.
  2. Connect the power jack to a power source and turn on the device.
  3. Connect the WAN and LAN ports of the device to the network using Ethernet cables.
  4. If required, insert a SIM card into the SIM card slot of the device.
  5. If required, connect an LTE or WiFi antenna to the device.
  6. Use the FXS and FXO ports to connect analog phones or PSTN lines to the device.
  7. Check the indicators on the front panel of the device to ensure proper functioning of the device. Refer to the user manual for details on each indicator.
  8. If you require technical support, contact Dinstar support by phone or email as provided in the user manual.

Thanks for Choosing Dinstar’s VoIP Gateway
Please read this guide carefully before installing the gateway. If you need any technical support, please contact us.
Tel : +86 755 61919966
Email : support@dinstar.com
Website : www.dinstar.com

UC120 Model and Interfaces

Model         Interface WAN LAN LTE FXS FXO
UC120-1V1S1O 1 1 1 1 1
UC120-1V2S 1 1 1 2 0
UC120-1V2O 1 1 1 0 2
UC120-1S1O 1 1 0 1 1
UC120-2S 1 1 0 2 0
UC120-2O 1 1 0 0 2

Indicators

Indicators Definition Status Description

PWR

|

Power Indicator

| ON| The device is powered on
OFF| The device is powered off or there is no

power supply

RUN

|

Running Indicator

| Slow Flashing| The device is running properly
Fast Flashing| The device is initializing
ON/OFF| The device is running improperly

FXS

|

In-use Indicator

| ON| FXS Port in-use
OFF| FXS port faulty
Slow Flashing| FXS port in idle status

FXO

|

In-use Indicator

| ON| In-use
OFF| FXO port faulty
Slow Flashing| FXO port in idle status

WAN/LAN

|

Network Link Indicator

| Fast Flashing| The device is properly connected to network
OFF| The device is not connected to network or network connection is improper

Wi-Fi

|

WiFi Enable/Disable Indicator

| ON| WiFi modular faulty
OFF| WiFi disabled or faulty
Fast Flashing| WiFi enabled

SIM

|

LTE Indicator

|

Fast Flashing

| SIM card is detected and registered to mobile network successfully.

The Indicator flash every 2 seconds.

Slow Flashing

| The device can not detect LTE/GSM module, or LTE

/GSM module is detected but SIM card is not detected;

The indicator flash every 4 seconds.

Note : some UC120 models do not have all the indicators described above. Please refer to the corresponding instructions above according to the indicator displayed on the front panel of the produ

Ports

DINSTAR-UC120-1V1S1-Wireless-USB-GSM 4G-VoLTE-IP-PBX-Voip-SIP-
Server-with-Wifi-Router-FIG- \(1\)

Installation Attentions

  1. The device accepts DC12V input. Please ensure a stable and safe power supply
  2. To reduce the interference with telephone calls, it’s highly recommended that telephone lines connected to the gateway should be placed away from power cables
  3. Please ensure there is enough network bandwidth so as to guarantee stabilized running of the device
  4. If WiFi is turned on, please ensure the WiFi antennas are well connected to the device
  5. If you want the device to communicate with the LTE network, please insert a SIM card

Installation Instruction

  • Antenna Installation

    • UC120-1V1S1O/1V2S/1V2O
      Install WiFi antenna (foldable antenna) and install LTE antenna (flat paddle antenna) on the rear panel

    • UC120-1S1O/2S/2O
      Install WiFi antenna (foldable antenna) on the rear panel of the device

  • Connect the power adapter to power jack (All models).

  • Insert SIM card to SIM slot (UC120-1V1S1O/1V2/1V2O).

  • Connect analog phone to FXS or connect landline to FXO (All models).

  • Connect network cable to WAN and LAN (All models)

    • Router mod
      UC120 supports router mode and bridge mode. The above figure shows the network connection in router mode. In router mode, the default IP of WAN port is DHCP, and the default IP of LAN port is 192.168.11.1

    • Bridge mode
      The above figure shows the network connection in bridge mode. In bridge mode, WAN and LAN port use the same IP address. The default IP address is 192.168.11.1.
      Note : UC120 can also be connected through Wi-Fi. The default SSID of the device is “domain_ [last 6 digits of MAC address] “ without password.

Login Web Management System

Open a web browser and enter the IP address of LAN port (the default IP is 192.168.11.1). You also can enter the IP address of WAN port, but it’s required to modify the IP address of PC to make it at the same network segment with that of WAN port. By default, the username is admin, while the password is admin@123#.DINSTAR-UC120-1V1S1-Wireless-USB-GSM 4G-VoLTE-IP-PBX-Voip-SIP-
Server-with-Wifi-Router-FIG- \(9\)

Check Mobile Network Status

For LTE device, view the SIM card status and signal strength on the “status → Overview” page, while for GSM devices, check the status on the “status → PSTN” pageDINSTAR-UC120-1V1S1-Wireless-USB-GSM 4G-VoLTE-IP-PBX-Voip-SIP-Server-
with-Wifi-Router-FIG- \(10\)

Modify Network Configuration

Please log into the device and click “network → settings” at the top menu bar to configure IP addresses of WAN and LAN portDINSTAR-UC120-1V1S1-Wireless-
USB-GSM 4G-VoLTE-IP-PBX-Voip-SIP-Server-with-Wifi-Router-FIG-
\(11\)

The default network mode of UC120 is router mode, and it can be set to bridge mode. In router mode, the IP address of WAN port and LAN port should be in different network segments. The default IP address of WAN port is obtained by DHCP, while the default IP address of LAN port is 192.168.11.1. In bridge mode, WAN port and LAN port use the same IP address. After modification, you need to click “apply” to make the settings take effect

Modify WiFi Settings

WiFi is enabled by default. Go to “network → WLAN” page to turn off the wireless or modify relevant parameters.DINSTAR-UC120-1V1S1-Wireless-USB-GSM
4G-VoLTE-IP-PBX-Voip-SIP-Server-with-Wifi-Router-FIG-
\(12\)
The default SSID of the device is “domain”_ [last six digits of MAC address] “. Except default SSID, users can create three more SSIDs. After modifying the WLAN parameters, you need to click “apply” to make the settings take effect.

Create SIP Extensions

On the Extension → SIP interface, you can configure the SIP accounts registered in the UC120 by SIP clients (hereby UC120 is regarded as a SIP server ).DINSTAR-UC120-1V1S1-Wireless-USB-GSM 4G-VoLTE-IP-PBX-Voip-SIP-
Server-with-Wifi-Router-FIG- \(13\) DINSTAR-UC120-1V1S1-Wireless-
USB-GSM 4G-VoLTE-IP-PBX-Voip-SIP-Server-with-Wifi-Router-FIG-
\(14\)

  • If the status of new added SIP account is “enabled”, it means that the UC120 accepts the registration of the extension.
  • If the status of the SIP account is “disabled”, it means that the UC120 rejected to register the extension. Up to 60 SIP accounts can be configured.
  • The registration status of SIP extension and SIP trunk can be checked on the “status → SIP” page.
  • After setting, you need to click “apply” to make the settings take effect.

SIP Trunk

SIP trunk can realize the connection between UC120 and IP PBX or SIP servers DINSTAR-UC120-1V1S1-Wireless-USB-GSM 4G-VoLTE-IP-PBX-Voip-SIP-Server-with-
Wifi-Router-FIG- \(15\)

  • If UC120 is regarded as a terminal and intends to register to a server, you need to configure a SIP trunk connecting UC120 and the server, and then enable register for the SIP trunk.
  • If the FXS f UC120 intends to register to a server, you need to configure a SIP trunk connecting UC120 and the server, then enable register for the port and designate the SIP trunk to it.

Configure outbound/inbound rule
On the Call Control → Route interface, you can configure routes for incoming calls and outgoing calls. DINSTAR-UC120-1V1S1-Wireless-USB-GSM 4G-VoLTE-IP-
PBX-Voip-SIP-Server-with-Wifi-Router-FIG- \(16\)

  • For the outbound route rule, destination can be FXO trunk, GSM trunk and SIP trunk;
  • For the inbound route rule, the destination can be SIP extension, FXS extension, local extension, ring group or IVR

Regular Expression

Caller/Called number prefix supports regular expression Regular Expression Syntax

^| Matches the starting position in a number string. For example, ^134 matches the numbers starting with 134.
---|---
$| Matches the ending position of a string. For example, 2$ matches the numbers ending with 2.
|| Separates alternate possibilities. For example, 2|3|4 means 2, 3 or 4.
¥| Marks the next character as a special character, a literal, a backreference, or an octal escape.
[ ]| Matches a single character that is contained within the bracket. For example, [123] matches

1, 2, or 3. [0-9] matches any digit from “0” to “9”.

[ ^ ]| Matches any one character except those enclosed in [ ]. For example, [^9] matches any

character except 9.

.| Matches any single character except the newline character. For example, 3.4 matches

314, 324, 334, 344.

?| Indicates there is zero or one of the preceding element. For example, colou?r matches both

color and colour.

| Indicates there is zero or more of the preceding element. For example, abc matches ac, abc,

abbc, abbbc, and so on.

+| Indicates there is one or more of the preceding element. For example, ab+c matches abc, abbc,

abbbc, and so on, but not ac.

/d| Mark any digit, equal to [0-9 ].
/D| Mark any character that is not a digit, equal to [^0-9 ].
/s| Mark any blank character such as a space or a tab.
/S| Mark any character that is not a blank character.

Example:

  • ^0755 matches the phone number start with 0755;
  • ^0755\d{8,9} matches the phone number start with 0755 and following 8 or 9 digits number length;
  • ^0755|^8899|^0110 matches the phone numbers with starting digits of 0755, 8899 or 0110.

Basic Operation

  • Dial *158# to query the IP address of LAN port of the device;
  • Dial *159# to query the IP address of WAN port of the device;
  • Dial *114# to query the telephone number of a FXS port;

Restart the device:

  1. Dial *111# to restart the device;
  2. Click “system->Reboot” menu to perform reboot;

RST button:

  • Under normal running status, press RST button 3 to 6 seconds will restore default username/password, and network mode will be changed to route mode as well. Other configurations will keep the same;
  • Under normal running status, press RST button 6 to 12 seconds, the device will restore factory default and reboot automatically;
  • When the device is power off, press RST button more than 30 seconds after it power on, the device will clear all the configurations and restore to mini-system management;

More Details
This document only provides instructions for quick installation and basic configuration. For detailed configuration and parameter explanation, please make reference to User Manual, or ask for online technical support.

Frequently Asked Questions

UC120 call priority (from high to low)

  • For the call between extensions, it is not necessary to configure any route, but to dial the extension number directly, which has the highest priority;
  • DID;
  • The route rule in the “call control → routing” page (the rule with lower index has higher priority);
  • Port registration configured in FXS extension, FXO trunk and GSM trunk.

Can the call between extensions be disabled?

Yes, disable internal call between extensions under the “call control → settings” page.

How many SIP extensions and concurrent calls can UC120 support?

UC120 supports 60 SIP extensions and 15 concurrent calls at max.

Can access the Internet through UC120 during making call through VoLTE?

If the operator’s network supports VoLTE and the SIM card used has already enabled VoLTE service, the call will go to volte network. At this time, the Internet connection of SIM card will not be disconnected during the call;
If the operator’s network does not support VoLTE or the SIM card does not enable volte service, the call will automatically fall back to 2G / 3G network, at this time, the SIM card Internet connection will be automatically disconnected (that is, the Internet cannot be accessed during the call).

The Gateway to VoIP World

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals