DINSTAR UC200-2S2O VoIP Gateway Installation Guide

May 15, 2024
DINSTAR

Quick Installation Guide
UC200-2S2O

UC200-2S2O VoIP Gateway

  1. UC200 Model and Interfaces
    Interface Model| WAN| LAN| FXS| FXO
    ---|---|---|---|---
    UC200-2S2O| 1| 1| 2| 2

Indicators

Indicators Definition Status Description
PWR Power Indicator ON The device is powered on
OFF The device is powered off or there is no power supply
RUN Running Indicator Slow Flashing The device is running properly
Fast Flashing The device is initializing
ON/OFF The device is running improperly
FXS In-use Indicator ON FXS Port in-use
OFF FXS port faulty
Slow Flashing FXS port in idle status
FXO In-use Indicator ON In-use
OFF FXO port faulty
Slow Flashing FXO port in idle status
WAN/LAN Network Link Indicator Fast Flashing The device is properly

connected to network
OFF| The device is not connected to network or network connection is improper

Indicators and PortsDINSTAR UC200-2S2O VoIP Gateway - Indicators and
Ports

 Installation Attentions

  • The device accepts DC12V input. Please ensure stable and safe power supply;
  • To reduce the interference with telephone calls, it’s highly recommended that telephone lines connected to the gateway should be placed away from power cables;
  • Please ensure there is enough network bandwidth so as to guarantee stabilized running of the device;
  • Please place the equipment on a horizontal surface if possible, do not stack the equipment to avoid heat dissipation;

Hardware installation & network connection

Connect the power adapter to power jack (All models). Connect analog phone to FXS or connect landline to FXO (All models). ![DINSTAR UC200-2S2O VoIP Gateway

  • analog phone](https://manuals.plus/wp-content/uploads/2024/03/DINSTAR-UC200 -2S2O-VoIP-Gateway-analog-phone.jpg)Connect network cable to WAN and LAN (All models)
    Router mode: DINSTAR UC200-2S2O VoIP Gateway - different IP
segmentUC200 supports router mode and bridge mode. The above figure shows the network connection in router mode. In router mode, the default IP of WAN port is DHCP, and the default IP of LAN port is 192.168.11.1.
    Bridge mode: DINSTAR UC200-2S2O VoIP Gateway - same IP
segmentThe above figure shows the network connection in bridge mode. In bridge mode, WAN and LAN port use the same IP address. The default IP address is 192.168.11.1.
    Login Web Management System
    Open a web browser and enter the IP address of LAN port (the default IP is 192.168.11.1). You also can enter the IP address of WAN port, but it’s required to modify the IP address of PC to make it at the same network segment with that of WAN port. By default, the username is admin and the password is admin@123#. DINSTAR UC200-2S2O VoIP Gateway - Management
System Modify Network Configuration
    Please log into the device and click “network → settings” at the top menu bar to configure IP addresses of WAN and LAN port.

The default network mode of UC200 is router mode, and it can be set to bridge mode. In router mode, the IP address of WAN port and LAN port should be in different network segments. The default IP address of WAN port is obtained by DHCP, while the default IP address of LAN port is 192.168.11.1. In bridge mode, WAN port and LAN port use the same IP address.
After modification, you need to “apply” to make the settings take effect.
Create SIP Extensions
On the Extension → SIP interface, you can configure the SIP accounts registered in the UC200 by SIP clients (hereby UC200 is regarded as a SIP server). DINSTAR UC200-2S2O VoIP Gateway - SIP
ExtensionsIf the status of new added SIP account is “enabled”, it means that the UC200 accepts the registration of the extension.
If the status of the SIP account is “disabled”, it means that the UC200 rejected to register the extension. Up to 200 SIP accounts can be configured.
The registration status of SIP extension and SIP trunk can be checked on the “status → SIP” page.
After setting, you need to click “apply” to make the settings take effect.

 SIP Trunk

SIP trunk can realize the connection between UC200 and IP PBX or SIP servers.
If UC200 is regarded as a terminal and intends to register to a server, you need to configure a SIP trunk connecting UC200 and the server, and then enable register for the SIP trunk.
If the UC200 intends to register to a server, you need to configure a SIP trunk connecting UC200 and the server.
Then enable register for the port and designate the SIP trunk to it. DINSTAR
UC200-2S2O VoIP Gateway - SIP TrunkConfigure outbound/inbound rule
On the Call Control → Route interface, you can configure routes for incoming calls and outgoing calls. For the outbound route rule, destination can be FXO trunk, GSM trunk and SIP trunk;
For the inbound route rule, the destination can be SIP extension, FXS extension, local extension, ring group or IVR.

Regular Expression

Caller/Called number prefix supports regular expression
Regular Expression Syntax

^| Matches the starting position in a number string. For example, ^134 matches the numbers starting with 134.
---|---
$| Matches the ending position of a string. For example, 2$ matches the numbers ending with 2.
|| Separates alternate possibilities. For example, 2|3|4 means 2, 3 or 4.
¥| Marks the next character as a special character, a literal, a backreference, or an octal escape.
[ ]| Matches a single character that is contained within the bracket. For example, [123] matches 1, 2, or 3. [0-9] matches any digit from “0” to “9”.
[ ^ ]| Matches any one character except those enclosed in [ ]. For example, [^9] matches any character except 9.
.| Matches any single character except the newline character. For example, 3.4 matches 314, 324, 334, 344.
?| Indicates there is zero or one of the preceding element. For example, colour matches both color and colour.
| Indicates there is zero or more of the preceding element. For example, abc matches ac, abc, abbc, abbbc, and so on.
+| Indicates there is one or more of the preceding element. For example, ab+c matches abc, abbc, abbbc, and so on, but not ac.
/d| Mark any digit, equal to [0-9 ].
/D| Mark any character that is not a digit, equal to [^0-9 ].
/s| Mark any blank character such as a space or a tab.
/S| Mark any character that is not a blank character.

Example:
^0755 matches the phone number start with 0755;
^0755\d{8,9} matches the phone number start with 0755 and following 8 or 9 digits number length;
^0755|^8899|^0110 matches the phone numbers with starting digits of 0755, 8899 or 0110.

Basic Operation

Dial 158# to query the IP address of LAN port of the device;
Dial
159# to query the IP address of WAN port of the device;
Dial 114# to query the telephone number of a FXS port;
Restart the device:
(1) Dial
111# to restart the device;
(2) Click “system->Reboot” menu to perform reboot;
RST button:

  1. Under normal running status, press RST button 3 to 6 seconds will restore default username/password, and network mode will be changed to route mode as well. Other configurations will keep the same;
  2. Under normal running status, press RST button 6 to 12 seconds, the device will restore factory default and reboot automatically;
  3. When the device is power off, press RST button more than 30 seconds after it power on, the device will clear all the configurations and restore to mini-system management;

More Details
This document only provides instructions for quick installation and basic configuration. For detailed configuration and parameter explanation, please check the User Manual, or ask for online technical support.

Frequently Asked Questions

(1) UC200 call priority (from high to low)

(2) Can the call between extensions be disabled?

(3) How many SIP extensions and concurrent calls can UC200 support?

UC200 supports 200 SIP extensions and 60 concurrent calls at max.

(4) After the port is configured to register to the remote SIP trunk, do I still need to configure outbound/inbound call routing?

No, after the port is configured and registered, there is already a route bound to the port and its registered SIP trunk. By default, and there is no need to configure it on the route configuration screen unless otherwise specifically requirement.

Thanks for Choosing Dinstar’s VoIP Gateway
Please read this guide carefully before installing the gateway. If you need any technical support, please contact us.
Tel: +86 755 61919966
Email: [email protected]
Website: www.dinstar.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

DINSTAR User Manuals

Related Manuals