DINSTAR DAG1000-1S1O VoIP Gateway Installation Guide
- June 12, 2024
- DINSTAR
Table of Contents
- DINSTAR DAG1000-1S1O VoIP Gateway
- Product Usage Instructions
- Models and Ports
- Description of Indicators
- Indicators and Ports
- Installation Attentions
- Installation Instructions
- Modify PC’s IP Address
- Basic Configurations of FXS
- Basic Configurations of FXO
- Basic Operations
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
DINSTAR DAG1000-1S1O VoIP Gateway
Product Information
The Dinstar VoIP Gateway is a device that enables Voice over Internet Protocol (VoIP) communication. It provides various models with different port configurations:
- DAG1000-1S1O: 1 WAN port, 1 LAN port, 1 FXS port, 1 FXO port
- DAG1000-2S2O: 1 WAN port, 1 LAN port, 2 FXS ports, 2 FXO ports
- DAG1000-2O: 1 WAN port, 1 LAN port, 2 FXO ports
The gateway has several indicators to provide status information:
- PWR (Power Indicator)
- RUN (Running Indicator)
- FXS (Telephone ln-use Indicator)
- FXO (FXO In-use Indicator)
- WAN/LAN (Network Link Indicator, Network Speed Indicator)
The indicators have different states and meanings, which are detailed in the user manual.
Product Usage Instructions
- Confirm the product model before installation.
- Follow the installation guideline for the specific model.
- Make the necessary connections as shown in the provided network connection diagram.
- Connect the telephone line and PSTN line as instructed.
- Connect the power adapter to the gateway and the power supply.
- Modify the IP address of the PC to be on the same network segment as the gateway.
- Access the Web Management System by entering the gateway’s IP address in a web browser.
- Log in with the default username and password (admin).
- If needed, modify the IP address of the gateway through the Web Management System.
THANKS FOR CHOOSING DINSTAR’S VOIP GATEWAY!
Please read this guide carefully before installing the gateway. If you need
any technical support, please contact us.
Models and Ports
Port Type
Model
| WAN| LAN| FXS| FXO
---|---|---|---|---
DAG1000-1S1O| 1| 1| 1| 1
DAG1000-2S2O| 1| 1| 2| 2
DAG1000-2O| 1| 1| /| 2
Please confirm your product model before installation and follow the installation guideline for the model.
Description of Indicators
Indicator | Definition | Status | Description |
---|---|---|---|
PWR | Power Indicator | On | The gateway is powered on. |
Off | The gateway is powered off or there is no |
power supply.
RUN
|
Running Indicator
| Slow
Flashing
| The gateway is running properly.
Fast Flashing| If there is a SIP account registered successfully, the
indicator is fast flashing.
Off| The gateway is running improperly.
FXS| Telephone ln-use Indicator| On| FXS port is currently occupied by a call.
Off| FXS port is idle or faulty.
FXO| FXO
In-use Indicator
| On| FXO port is currently occupied.
Off| FXO Port is idle or faulty.
WAN/LAN
|
Network Link Indicator
| Green
Flashing
| The gateway is properly connected to network.
Off| The gateway is not connected to network or network connection is improper
way.
Network Speed Indicator| On| Work at 100Mbps.
Off| Work at 10Mbps.
Indicators and Ports
DAG1000-1S1O
DAG1000-2S2O
DAG1000-2O
Installation Attentions
- Anti-jamming: to reduce the interference with telephone calls, it’s highly recommended that telephone lines connected to the gateway should be placed away from power cables.
- Power supply: DAG1000-1S1O, DAG1000-2S2O and DAG1000-2O are equipped with 12VDC power adapter. Please ensure safe and stable power supply.
- Network bandwidth: please ensure there is enough network bandwidth so as to guarantee stabilized running of the gateway.
- Temperature and humidity: to avoid any accident that might cause malfunction, it’s advised to install the gateway in an equipment room where temperature and humidity are appropriate.
- Ventilation: to avoid overheating, please do not pile up the gateway with other devices and make sure the gateway has good ventilation around.
- Mechanical load: please make sure the gateway is placed steadily to avoid damage. It’s highly advised to horizontally place the gateway on a flat surface or a cabinet.
Installation Instructions
Connection Diagram for DAG1000
- Network Connection
- Telephone Connection
- PSTN Connection
- Power Connection
Modify PC’s IP Address
To log in the Web Management System of the gateway, firstly, you need to modify the IP address of PC which is used to access the gateway and to make it at the same network segment with the gateway.
- On the PC, click ‘Network (or Ethernet) →Properties’.
- Double-click ‘Internet Protocol Version 4 (TCP/IPv4)’.
- Select ‘Use the following IP address’, and then enter an available IP address ‘192.168.11.XXX’ which is at the same network segment with ‘192.168.11.1’.
Log in Web Management System
Open a web browser and enter the gateway’s IP address (default IP is 192.168.11.1). Then, input username and password in the displayed login GUI. Both the default username and password are admin.
Modify Gateway’s IP Address
If you want to modify the IP address of DAG1000-1S/2S/4S, please click ‘Network → Local Network’ in the navigation tree on the left of the Web Management System, and then input new IP address and DNS server address on the displayed interface.
Basic Configurations of FXS
-
Configure SIP Server
Log in the Web Management System of the gateway, and then click SIP Server in the navigation tree and then enter the address of the SIP server which is to be registered. Click Save in the last. -
Configure SIP Account Information
Click Port in the navigation tree on the left, and then click Add. Input the SIP account and authentication password assigned by the SIP server.
Click Save and then restart the gateway for the new configurations to take effect.
Basic Configurations of FXO
-
Configure Port Group
You are advised to divide PSTN lines into several groups and then distribute them to different port groups. Generally, PSTN lines belonging to a same telecom operator are distributed to a same port group.
Click Call & Routing→Port Group, and then click Add on the displayed interface .
When calls come from PSTN to the gateway, the off-hook auto-dial number is generally regarded as the DID (Direct-inward-dial) number or destination number of the SIP server.
Click Select Port for this Group, and the following interface will be displayed. -
Configure IP Trunk
On the Call & Routing→IP Trunk interface, click Add to create an IP trunk which connects to a peer SIP server. -
) Create Outbound Route
On the Call & Routing→<IP→Tel Routing> interface, click Add to create an outbound route for the IP trunk.
As shown in the following figure, Caller/Callee Prefix is set as ‘any’ and calls from IP
trunk 63are routed to port group 1 .
On the Call & Routing→<Tel→IP/Tel Routing> interface, click Add to create an inbound route for -
Create Inbound Route
the IP trunk. As shown in the following figure, Caller Prefix is set as‘any’ and calls from port group 1are routed to IP trunk 63 .
Configure FXO Parameters
On the Advanced →FXS/FXO interface, configure the gateway to detect CID after ring or before ring, and enable ‘Send Original CID when call from PSTN’. Format of “from” field is set as ‘CID/CID’ when CID is available, while format of “from” field is set as‘Display/User ID’ when CID is unavailable.
Configure Priority of Codecs
On the Advanced→Media Parameter interface, configure the priority of preferred
codecs. The gateway supports G.729, G.723, G.711U and G.711A.
Configure Impedance Value
To improve the compatibility of FXO ports, the gateway provides auto test to
get the most matched impedance value.
On the Advanced→FXS/FXO interface, click Start Test and then the gateway will
automatically detect the best impedance for FXO lines. After the test is
complete, save the impedance value.
Basic Operations
- Dial *158# to query the IP address of LAN port of the gateway;
- Dial *159# to query the IP address of WAN port of the gateway;
- Dial *114# to query the telephone number of a FXS port;
- Dial 165000000# to restore default IP address, user name and password; Restore factory default settings:
- dial 166000000#;
- press the RST button for 7 seconds;
- Log in the gateway and then click ‘Tools →Factory Reset’, then click Apply and restart the gateway.
- Dial *111# to restart the gateway.
More Details
This document only provides instructions for quick installation and basic configuration, for detailed configuration and parameter explanation, please make reference to user manual or ask for online technical support.
IP COMMUNICATION SOLUTIONS
Tel: +86 755 61919966
Email: support@dinstar.com
Web: www.dinstar.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>