MEAN WELL RSP-100 Series 100W Single Output with PFC Function Owner’s Manual
- June 25, 2024
- MEAN WELL
Table of Contents
100W Single Output with PFC Function
RSP-100 series
Dimension
L W H
179 99 30 mm
7.05 3.90 1.18 inch
R33100 AS/NZS62368-1 UL62368-1 BS EN/EN62368-1
RoHS BS
EN/EN61558-1
CNS14336-1 BS EN/EN61558-2-16
GB4943.1 TPTC004 IEC62368-1
Features
- Universal AC input / Full range
- Built-in active PFC function
- High efficiency up to 88%
- Cooling by free air convection
- Built-in remote ON-OFF control
- Protections: Short circuit / Overload / Over voltage / Over temperature
- LED indicator for power on
- 3 years warranty
Applications
- Factory control or automation apparatus
- Test and measurement instrument
- Laser related machine
- Burn-in facility
- RF application
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
RSP-100 is a 100W single output enclosed type AC/DC power supply. This series operates for 85~264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by free air convection, working for the temperature up to 70°C.
Model Encoding / Order Information
- Output voltage (3.3V/5V/7.5V/12V/13.5V/15V/24V/27V/48V)
- Output wattage
- Series name
SPECIFICATION
MODEL | RSP-100-3.3 | RSP-100-5 | RSP-100-7.5 |
---|---|---|---|
OUTPUT | DC VOLTAGE | 3.3V | 5V |
RATED CURRENT | 20A | 20A | 13.5A |
CURRENT RANGE | 0 ~ 20A | 0 ~ 20A | 0 ~ 13.5A |
RATED POWER | 66W | 100W | 101.25W |
RIPPLE & NOISE (max.) Note.2 | 100mVp-p | 100mVp-p | 100mVp-p |
VOLTAGE ADJ. RANGE | 3.14 ~ 3.63V | 4.75 ~ 5.5V | 7.13 ~ 8.25V |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±2.0% | ±2.0% |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% |
LOAD REGULATION | ±1.0% | ±1.0% | ±1.0% |
SETUP, RISE TIME | 600ms, 30ms at full load | ||
HOLD UP TIME (Typ.) | 16ms at full load | ||
INPUT | VOLTAGE RANGE | 85 ~ 264VAC 120 ~ 370VDC | |
FREQUENCY RANGE | 47 ~ 63Hz | ||
POWER FACTOR (Typ.) | PF>0.93/230VAC PF>0.98/115VAC at full load | ||
EFFICIENCY (Typ.) | 83% | 86% | 87% |
AC CURRENT (Typ.) | 1.1A/115VAC 0.55A/230VAC | ||
INRUSH CURRENT (Typ.) | COLD START 30A/230VAC | ||
LEAKAGE CURRENT | <2mA / 240VAC | ||
PROTECTION | OVERLOAD | 105 ~ 135% rated output power |
Protection type : Constant current limiting, recovers automatically after
fault condition is removed
OVER VOLTAGE| 3.63 ~ 4.46V| 5.5 ~ 6.75V| 8.25 ~ 10.13V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after
temperature goes down
FUNCTION| REMOTE CONTROL| CN1: < 0~0.8VDC POWER ON , 4~10VDC POWER
OFF
ENVIRONMENT| WORKING TEMP.| -30 ~ +70°C (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85°C, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.05%/°C (0 ~ 50°C)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
OVER VOLTAGE CATEGORY| III; According to EN61558, EN50178,EN60664-1,
EN62477-1; altitude up to 2000 meters
SAFETY & EMC (Note 4)| SAFETY STANDARDS| UL62368-1, TUV BS
EN/EN62368-1, BS EN/EN61558-1, BS EN/EN61558-2-16, EAC TP TC 004, CCC
GB4943.1, BSMI CNS14336-1 approved, Design refer to AS/NZS 62368.1
WITHSTAND VOLTAGE| I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/
70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS
EN/EN61000-3-2,-3, EAC TP TC 020, CNS13438, GB9254 Class B, GB17625.1
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS
EN/EN55035, light industry level, EAC TP TC 020
OTHERS| MTBF| 2325.2K hrs min. Telcordia SR-332 (Bellcore) ;
288.5K hrs min. MIL-HDBK-217F (25°C)
DIMENSION| 1799930mm (LWH)
PACKING| 0.52Kg; 24pcs/14.5Kg/0.81CUFT
NOTE|
- All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
- Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- Tolerance : includes set up tolerance, line regulation and load regulation.
- The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- Strongly recommended that external output capacitance should not exceed 5000uF.(Only for: RSP-100-3.3/-5/-7.5)
- The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft).
Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
MODEL | RSP-100-12 | RSP-100-13.5 | RSP-100-15 |
---|---|---|---|
OUTPUT | DC VOLTAGE | 12V | 13.5V |
RATED CURRENT | 8.5A | 7.5A | 6.7A |
CURRENT RANGE | 0 ~ 8.5A | 0 ~ 7.5A | 0 ~ 6.7A |
RATED POWER | 102W | 101.25W | 100.5W |
RIPPLE & NOISE (max.) Note.2 | 100mVp-p | 100mVp-p | 100mVp-p |
VOLTAGE ADJ. RANGE | 11.4 ~ 13.2V | 12.8 ~ 14.9V | 14.3 ~ 16.5V |
VOLTAGE TOLERANCE Note.3 | ±1.0% | ±1.0% | ±1.0% |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% |
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% |
SETUP, RISE TIME | 600ms, 30ms at full load | ||
HOLD UP TIME (Typ.) | 16ms at full load | ||
INPUT | VOLTAGE RANGE | 85 ~ 264VAC 120 ~ 370VDC | |
FREQUENCY RANGE | 47 ~ 63Hz | ||
POWER FACTOR (Typ.) | PF>0.93/230VAC PF>0.98/115VAC at full load | ||
EFFICIENCY (Typ.) | 86% | 86.5% | 87% |
AC CURRENT (Typ.) | 1.1A/115VAC 0.55A/230VAC | ||
INRUSH CURRENT (Typ.) | COLD START 30A/230VAC | ||
LEAKAGE CURRENT | <2mA / 240VAC | ||
PROTECTION | OVERLOAD | 105 ~ 135% rated output power |
Protection type : Constant current limiting, recovers automatically after
fault condition is removed
OVER VOLTAGE| 13.2 ~ 16.2V| 14.85 ~ 18.23V| 16.5 ~ 20.25V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after
temperature goes down
FUNCTION| REMOTE CONTROL| CN1: < 0~0.8VDC POWER ON , 4~10VDC POWER
OFF
ENVIRONMENT| WORKING TEMP.| -30 ~ +70°C (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85°C, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.05%/°C (0 ~ 50°C)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
OVER VOLTAGE CATEGORY| III; According to EN61558, EN50178,EN60664-1,
EN62477-1; altitude up to 2000 meters
SAFETY & EMC (Note 4)| SAFETY STANDARDS| UL62368-1, TUV BS
EN/EN62368-1, BS EN/EN61558-1, BS EN/EN61558-2-16, EAC TP TC 004, CCC
GB4943.1, BSMI CNS14336-1 approved, Design refer to AS/NZS 62368.1
WITHSTAND VOLTAGE| I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/
70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS
EN/EN61000-3-2,-3, EAC TP TC 020, CNS13438, GB9254 Class B, GB17625.1
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS
EN/EN55035, light industry level, EAC TP TC 020
OTHERS| MTBF| 2325.2K hrs min. Telcordia SR-332 (Bellcore) ;
288.5K hrs min. MIL-HDBK-217F (25°C)
DIMENSION| 1799930mm (LWH)
PACKING| 0.52Kg; 24pcs/14.5Kg/0.81CUFT
NOTE|
- All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
- Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- Tolerance : includes set up tolerance, line regulation and load regulation.
- The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- Strongly recommended that external output capacitance should not exceed 5000uF.(Only for: RSP-100-3.3/-5/-7.5)
- The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft).
Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
MODEL | RSP-100-24 | RSP-100-27 | RSP-100-48 |
---|---|---|---|
OUTPUT | DC VOLTAGE | 24V | 27V |
RATED CURRENT | 4.2A | 3.8A | 2.1A |
CURRENT RANGE | 0 ~ 4.2A | 0 ~ 3.8A | 0 ~ 2.1A |
RATED POWER | 100.8W | 102.6W | 100.8W |
RIPPLE & NOISE (max.) Note.2 | 150mVp-p | 150mVp-p | 250mVp-p |
VOLTAGE ADJ. RANGE | 22.8 ~ 26.4V | 25.7 ~ 29.7V | 45.6 ~ 52.8V |
VOLTAGE TOLERANCE Note.3 | ±1.0% | ±1.0% | ±1.0% |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% |
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% |
SETUP, RISE TIME | 600ms, 30ms at full load | ||
HOLD UP TIME (Typ.) | 16ms at full load | ||
INPUT | VOLTAGE RANGE | 85 ~ 264VAC 120 ~ 370VDC | |
FREQUENCY RANGE | 47 ~ 63Hz | ||
POWER FACTOR (Typ.) | PF>0.93/230VAC PF>0.98/115VAC at full load | ||
EFFICIENCY (Typ.) | 87% | 87% | 88% |
AC CURRENT (Typ.) | 1.1A/115VAC 0.55A/230VAC | ||
INRUSH CURRENT (Typ.) | COLD START 30A/230VAC | ||
LEAKAGE CURRENT | <2mA / 240VAC | ||
PROTECTION | OVERLOAD | 105 ~ 135% rated output power |
Protection type : Constant current limiting, recovers automatically after
fault condition is removed
OVER VOLTAGE| 26.4 ~ 32.4V| 29.7 ~ 36.45V| 52.8 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after
temperature goes down
FUNCTION| REMOTE CONTROL| CN1: < 0~0.8VDC POWER ON , 4~10VDC POWER
OFF
ENVIRONMENT| WORKING TEMP.| -30 ~ +70°C (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85°C, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.05%/°C (0 ~ 50°C)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
OVER VOLTAGE CATEGORY| III; According to EN61558, EN50178,EN60664-1,
EN62477-1; altitude up to 2000 meters
SAFETY & EMC (Note 4)| SAFETY STANDARDS| UL62368-1, TUV BS
EN/EN62368-1, BS EN/EN61558-1, BS EN/EN61558-2-16, EAC TP TC 004, CCC
GB4943.1, BSMI CNS14336-1 approved, Design refer to AS/NZS 62368.1
WITHSTAND VOLTAGE| I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/
70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS
EN/EN61000-3-2,-3, EAC TP TC 020, CNS13438, GB9254 Class B, GB17625.1
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS
EN/EN55035, light industry level, EAC TP TC 020
OTHERS| MTBF| 2325.2K hrs min. Telcordia SR-332 (Bellcore) ;
288.5K hrs min. MIL-HDBK-217F (25°C)
DIMENSION| 1799930mm (LWH)
PACKING| 0.52Kg; 24pcs/14.5Kg/0.81CUFT
NOTE|
- All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
- Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- Tolerance : includes set up tolerance, line regulation and load regulation.
- The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- Strongly recommended that external output capacitance should not exceed 5000uF.(Only for: RSP-100-3.3/-5/-7.5)
- The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft).
Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Mechanical Specification
Case No.227A Unit: mm
- 4-M4(Both Sides) L=4mm
Terminal Pin No. Assignment
Pin No.
| Assignment| Pin No.| Assignment
---|---|---|---
1| AC/L| 4,5|
DC OUTPUT -V
2
| AC/N| 6,7| DC OUTPUT +V
3| FG | |
Remote ON/OFF(CN1): JST S2B-XH or equivalent(optional)
Pin No.
| Assignment| Mating Housing| Terminal
---|---|---|---
1| RC+| JST XHP or equivalent|
JST SXH-001T-P0.6 or equivalent
2
|
RC-
Block Diagram
PFC fosc : 100KHz
PWM fosc : 100KHz
- EMI FILTER & RECTIFIERS
- PFC CIRCUIT
- POWER SWITCHING
- RECTIFIERS & FILTER
- ACTIVE START CIRCUIT
- PWM & PFC CONTROL
- CONSTANT CURRENT & DETECTION CIRCUIT
- REMOTE CONTROL
Derating Curve
Output Derating VS Input Voltage
File Name:RSP-100-SPEC 2024-02-23
Downloaded from Arrow.com.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>