MEAN WELL RSP-100 Series 100W Single Output with PFC Function Owner’s Manual

June 25, 2024
MEAN WELL

100W Single Output with PFC Function

RSP-100 series


User’s Manual
MEAN WELL RSP-100 Series 100W Single Output with PFC Function - QR
Code

Dimension

L                 W                  H
179             99                  30    mm
7.05           3.90               1.18  inch

                           

R33100    AS/NZS62368-1  UL62368-1   BS EN/EN62368-1
RoHS                                                         BS EN/EN61558-1
CNS14336-1                                          BS EN/EN61558-2-16

GB4943.1   TPTC004   IEC62368-1

Features
  • Universal AC input / Full range
  • Built-in active PFC function
  • High efficiency up to 88%
  • Cooling by free air convection
  • Built-in remote ON-OFF control
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • LED indicator for power on
  • 3 years warranty
Applications
  • Factory control or automation apparatus
  • Test and measurement instrument
  • Laser related machine
  • Burn-in facility
  • RF application
GTIN CODE

MW Search: https://www.meanwell.com/serviceGTIN.aspx

Description

RSP-100 is a 100W single output enclosed type AC/DC power supply. This series operates for 85~264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by free air convection, working for the temperature up to 70°C.

Model Encoding / Order Information
  1. Output voltage (3.3V/5V/7.5V/12V/13.5V/15V/24V/27V/48V)
  2. Output wattage
  3. Series name
SPECIFICATION
MODEL RSP-100-3.3 RSP-100-5 RSP-100-7.5
OUTPUT DC VOLTAGE 3.3V 5V
RATED CURRENT 20A 20A 13.5A
CURRENT RANGE 0 ~ 20A 0 ~ 20A 0 ~ 13.5A
RATED POWER 66W 100W 101.25W
RIPPLE & NOISE (max.)   Note.2 100mVp-p 100mVp-p 100mVp-p
VOLTAGE ADJ. RANGE 3.14 ~ 3.63V 4.75 ~ 5.5V 7.13 ~ 8.25V
VOLTAGE TOLERANCE   Note.3 ±2.0% ±2.0% ±2.0%
LINE REGULATION ±0.5% ±0.5% ±0.5%
LOAD REGULATION ±1.0% ±1.0% ±1.0%
SETUP, RISE TIME 600ms, 30ms at full load
HOLD UP TIME (Typ.) 16ms at full load
INPUT VOLTAGE RANGE 85 ~ 264VAC   120 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR (Typ.) PF>0.93/230VAC   PF>0.98/115VAC at full load
EFFICIENCY (Typ.) 83% 86% 87%
AC CURRENT (Typ.) 1.1A/115VAC   0.55A/230VAC
INRUSH CURRENT (Typ.) COLD START 30A/230VAC
LEAKAGE CURRENT <2mA / 240VAC
PROTECTION OVERLOAD 105 ~ 135% rated output power

Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE| 3.63 ~ 4.46V| 5.5 ~ 6.75V| 8.25 ~ 10.13V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION| REMOTE CONTROL| CN1: < 0~0.8VDC POWER ON , 4~10VDC POWER OFF
ENVIRONMENT| WORKING TEMP.| -30 ~ +70°C (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85°C, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.05%/°C (0 ~ 50°C)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
OVER VOLTAGE CATEGORY| III; According to EN61558, EN50178,EN60664-1, EN62477-1; altitude up to 2000 meters
SAFETY & EMC   (Note 4)| SAFETY STANDARDS| UL62368-1, TUV BS EN/EN62368-1, BS EN/EN61558-1, BS EN/EN61558-2-16, EAC TP TC 004, CCC GB4943.1, BSMI CNS14336-1 approved, Design refer to AS/NZS 62368.1
WITHSTAND VOLTAGE| I/P-O/P:4KVAC   I/P-FG:2KVAC   O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020, CNS13438, GB9254 Class B, GB17625.1
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020
OTHERS| MTBF| 2325.2K hrs min.   Telcordia SR-332 (Bellcore) ; 288.5K hrs min.   MIL-HDBK-217F (25°C)
DIMENSION| 1799930mm (LWH)
PACKING| 0.52Kg; 24pcs/14.5Kg/0.81CUFT
NOTE|

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
  5. Strongly recommended that external output capacitance should not exceed 5000uF.(Only for: RSP-100-3.3/-5/-7.5)
  6. The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft).

Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

MODEL RSP-100-12 RSP-100-13.5 RSP-100-15
OUTPUT DC VOLTAGE 12V 13.5V
RATED CURRENT 8.5A 7.5A 6.7A
CURRENT RANGE 0 ~ 8.5A 0 ~ 7.5A 0 ~ 6.7A
RATED POWER 102W 101.25W 100.5W
RIPPLE & NOISE (max.)   Note.2 100mVp-p 100mVp-p 100mVp-p
VOLTAGE ADJ. RANGE 11.4 ~ 13.2V 12.8 ~ 14.9V 14.3 ~ 16.5V
VOLTAGE TOLERANCE   Note.3 ±1.0% ±1.0% ±1.0%
LINE REGULATION ±0.5% ±0.5% ±0.5%
LOAD REGULATION ±0.5% ±0.5% ±0.5%
SETUP, RISE TIME 600ms, 30ms at full load
HOLD UP TIME (Typ.) 16ms at full load
INPUT VOLTAGE RANGE 85 ~ 264VAC   120 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR (Typ.) PF>0.93/230VAC   PF>0.98/115VAC at full load
EFFICIENCY (Typ.) 86% 86.5% 87%
AC CURRENT (Typ.) 1.1A/115VAC   0.55A/230VAC
INRUSH CURRENT (Typ.) COLD START 30A/230VAC
LEAKAGE CURRENT <2mA / 240VAC
PROTECTION OVERLOAD 105 ~ 135% rated output power

Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE| 13.2 ~ 16.2V| 14.85 ~ 18.23V| 16.5 ~ 20.25V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION| REMOTE CONTROL| CN1: < 0~0.8VDC POWER ON , 4~10VDC POWER OFF
ENVIRONMENT| WORKING TEMP.| -30 ~ +70°C (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85°C, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.05%/°C (0 ~ 50°C)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
OVER VOLTAGE CATEGORY| III; According to EN61558, EN50178,EN60664-1, EN62477-1; altitude up to 2000 meters
SAFETY & EMC   (Note 4)| SAFETY STANDARDS| UL62368-1, TUV BS EN/EN62368-1, BS EN/EN61558-1, BS EN/EN61558-2-16, EAC TP TC 004, CCC GB4943.1, BSMI CNS14336-1 approved, Design refer to AS/NZS 62368.1
WITHSTAND VOLTAGE| I/P-O/P:4KVAC   I/P-FG:2KVAC   O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020, CNS13438, GB9254 Class B, GB17625.1
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020
OTHERS| MTBF| 2325.2K hrs min.   Telcordia SR-332 (Bellcore) ; 288.5K hrs min.   MIL-HDBK-217F (25°C)
DIMENSION| 1799930mm (LWH)
PACKING| 0.52Kg; 24pcs/14.5Kg/0.81CUFT
NOTE|

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
  5. Strongly recommended that external output capacitance should not exceed 5000uF.(Only for: RSP-100-3.3/-5/-7.5)
  6. The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft).

Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

MODEL RSP-100-24 RSP-100-27 RSP-100-48
OUTPUT DC VOLTAGE 24V 27V
RATED CURRENT 4.2A 3.8A 2.1A
CURRENT RANGE 0 ~ 4.2A 0 ~ 3.8A 0 ~ 2.1A
RATED POWER 100.8W 102.6W 100.8W
RIPPLE & NOISE (max.)   Note.2 150mVp-p 150mVp-p 250mVp-p
VOLTAGE ADJ. RANGE 22.8 ~ 26.4V 25.7 ~ 29.7V 45.6 ~ 52.8V
VOLTAGE TOLERANCE   Note.3 ±1.0% ±1.0% ±1.0%
LINE REGULATION ±0.5% ±0.5% ±0.5%
LOAD REGULATION ±0.5% ±0.5% ±0.5%
SETUP, RISE TIME 600ms, 30ms at full load
HOLD UP TIME (Typ.) 16ms at full load
INPUT VOLTAGE RANGE 85 ~ 264VAC   120 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR (Typ.) PF>0.93/230VAC   PF>0.98/115VAC at full load
EFFICIENCY (Typ.) 87% 87% 88%
AC CURRENT (Typ.) 1.1A/115VAC   0.55A/230VAC
INRUSH CURRENT (Typ.) COLD START 30A/230VAC
LEAKAGE CURRENT <2mA / 240VAC
PROTECTION OVERLOAD 105 ~ 135% rated output power

Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE| 26.4 ~ 32.4V| 29.7 ~ 36.45V| 52.8 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION| REMOTE CONTROL| CN1: < 0~0.8VDC POWER ON , 4~10VDC POWER OFF
ENVIRONMENT| WORKING TEMP.| -30 ~ +70°C (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85°C, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.05%/°C (0 ~ 50°C)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
OVER VOLTAGE CATEGORY| III; According to EN61558, EN50178,EN60664-1, EN62477-1; altitude up to 2000 meters
SAFETY & EMC   (Note 4)| SAFETY STANDARDS| UL62368-1, TUV BS EN/EN62368-1, BS EN/EN61558-1, BS EN/EN61558-2-16, EAC TP TC 004, CCC GB4943.1, BSMI CNS14336-1 approved, Design refer to AS/NZS 62368.1
WITHSTAND VOLTAGE| I/P-O/P:4KVAC   I/P-FG:2KVAC   O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020, CNS13438, GB9254 Class B, GB17625.1
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020
OTHERS| MTBF| 2325.2K hrs min.   Telcordia SR-332 (Bellcore) ; 288.5K hrs min.   MIL-HDBK-217F (25°C)
DIMENSION| 1799930mm (LWH)
PACKING| 0.52Kg; 24pcs/14.5Kg/0.81CUFT
NOTE|

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
  5. Strongly recommended that external output capacitance should not exceed 5000uF.(Only for: RSP-100-3.3/-5/-7.5)
  6. The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft).

Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

 Mechanical Specification

Case No.227A   Unit: mm

  1. 4-M4(Both Sides) L=4mm

Terminal Pin No. Assignment

Pin No.

| Assignment| Pin No.| Assignment
---|---|---|---
1| AC/L| 4,5|

DC OUTPUT -V

2

| AC/N| 6,7| DC OUTPUT +V
3| FG | |

Remote ON/OFF(CN1): JST S2B-XH or equivalent(optional)

Pin No.

| Assignment| Mating Housing| Terminal
---|---|---|---
1| RC+| JST XHP or equivalent|

JST SXH-001T-P0.6 or equivalent

2

|

RC-

Block Diagram

PFC fosc : 100KHz
PWM fosc : 100KHz

MEAN WELL RSP-100 Series 100W Single Output with PFC Function -
a4

  1. EMI FILTER & RECTIFIERS
  2. PFC CIRCUIT
  3. POWER SWITCHING
  4. RECTIFIERS & FILTER
  5. ACTIVE START CIRCUIT
  6. PWM & PFC CONTROL
  7. CONSTANT CURRENT & DETECTION CIRCUIT
  8. REMOTE CONTROL
Derating Curve
Output Derating VS Input Voltage

File Name:RSP-100-SPEC   2024-02-23

Downloaded from Arrow.com.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals