inventor O1MI-18B Air Conditioning Systems User Manual

June 20, 2024
inventor

inventor logo AIR CONDITIONING SYSTEMS
REMOTE CONTROLLER
• USER’S MANUAL

O1MI-18B Air Conditioning Systems

MODELS:
O1MI-09F(CP)/O1MO-09F(CP)
O1MI-12F(CP)/O1MO-12F(CP)
O1MI-18B/O1MO-18B
O1MI-24/O1MO-24B

NOTE:

  • Buttons design is based on typical model and might be slightly different from the actual one you purchased,the actual shape shall prevail.
  • All the functions described are accomplished by the unit. If the unit has no this feature, there is no corresponding operation happened when press the relative button on the remote controller.
  • When there are wide differences between Remote controller Illustration and USER’S MANUAL on function description, the description of USER’S MANUAL shall prevail.

Remote Controller Specifications

Model 3.0V(Dry batteries R03/LR03×2)
Rated Voltage RG57A3/BGEF, RG57B/BGE,RG57D/BGERG57A2/BGEF,
Signal Receiving Range 8m
Environment -5ºC~60ºC

inventor O1MI 18B Air Conditioning Systems - Remote Controller
Specifications 1|
---|---
RG57A3/BGEF
RG57A2/BGEF
(FRESH button is not available)| RG57B/BGE
(FRESH button is not available)
RG57D/BGE

Operation of buttons

inventor O1MI 18B Air Conditioning Systems - Operation of
buttons

  1. ON/OFF Button
    This button turns the air conditioner ON and OFF.

  2. MODE Button
    Press this button to modify the air conditioner mode in a sequence of following:inventor O1MI 18B Air Conditioning Systems - MODE
Button NOTE: Please do not select HEAT mode if the machine you purchased is cooling only type. Heat mode is not supported by the cooling only appliance.

  3. FAN Button
    Used to select the fan speed in four steps:inventor O1MI 18B Air
Conditioning Systems - FAN Button NOTE: You can not switch the fan speed in AUTO or DRY mode.

  4. SLEEP Button
    Active/Disable sleep function. It can maintain the most comfortable temperature and save energy. This function is available on COOL, HEAT or AUTO mode only.
    For the detail, see “sleep operation” in “USER S MANUAL.”
    NOTE: While the unit is running under SLEEP mode, it would be cancelled if MODE, FAN SPEED or ON/OFF button is pressed.

  5. FRESH Button (applicable to RG57A3/BGEF and RG57D/BGE only)
    Active/Disable When the FRESH function is initiated, the Ionizer/ Plasma Dust Collector(depending on models) is energized and will help to remove pollen and impurities from the air.

  6. TURBO Button
    Active/Disable Turbo function. Turbo function enables the unit to reach the preset temperature at cooling or heating operation in the shortest time(if the indoor unit does not support this function, there is no corresponding operation happened when pressing this button.)

  7. SELF CLEAN Button (applicable to Rg57(A2)A3/BGEF) Active/Disable Self Clean functioninventor O1MI 18B Air Conditioning Systems - Operation of buttons 2

  8. UP Button (▲)
    Push this button to increase the indoor temperature setting in 1ºC increments to 30ºC.
    DOWN Button (▼)
    Push this button to decrease the indoor temperature setting in 1ºC increments to 17ºC.
    NOTE: Temperature contol is not available in Fan mode.

  9. SHORTCUT Button
    ● Used to restore the current settings or resume previous settings.
    ● On the first time connecting to the power, if push the SHORTCUT button, the unit will operate on AUTO mode, 26ºC, and fan speed is Auto.
    ● Push this button when remote controller is on, the system will automatically revert back to the previous settings including operating mode, setting temperature, fan speed level and sleep feature(if activated).
    ● If pushing more than 2 seconds, the system will automatically restore the current operation settings including operating mode, setting temperature, fan speed level and sleep feature(if activated ).

  10. TIMER ON Button
    Press this button to initiate the auto-on time sequence. Each press will increase the auto-timed setting in 30 minutes increments. When the setting time displays 10.0, each press will increase the autotimed setting 60 minutes increments. To cancel the auto-timed program, simply adjust the auto-on time to 0.0.

  11. TIMER OFF Button
    Press this button to initiate the auto-off time sequence. Each press will increase the auto-timed setting in 30 minutes increments.
    When the setting time displays 10.0, each press will increase the auto-timed setting 60 minutes increments. To cancel the autotimed program, simply adjust the auto-off time to 0.0

inventor O1MI 18B Air Conditioning Systems - Operation of buttons
3| inventor O1MI 18B Air
Conditioning Systems - Operation of buttons 4
---|---
12. Swing ◀▶Button (applicable to RG57(A2)A3/BGEF)
Used to stop or start vertical louver movement and set the desired left/right air flow direction. The vertical louver changes 6 degree in angle for each press. And the temperature display area of indoor unit displays ‘ ‘ for one second. If keep pushing more than 2 seconds, the vertical louver swing feature is activated. And the display area of indoor unit displays ‘IIII’, flashes four times, then the temperature setting reverts back. If the vertical louver swing feature is stopped, it displays ‘LC’ and remains on for 3 seconds.
Swing Button (applicable to RG57A3(A2)/BGEF)
Used to stop or start horizontal louver movement or set the desired up/down air flow direction. The louver changes 6 degree in angle for each press. If keep pushing more than 2 seconds, the louver will swing up and down automatically.
SWING Button (applicable to RG57B(D)/BGE)
Used to stop or start horizontal louver auto swing feature.
DIRECT Button (applicable to RG57B(D)/BGE)
Used to change the louver movement and set the desired up/down air flow direction. The louver changes 6º in angle for each press.

  1. FOLLOW ME Button
    (applicable to RG57(A2)A3/BGEF)
    Push this button to initiate the Follow Me feature, the remote display is actual temperature at its location. The remote control will send this signal to the air conditioner every 3 minutes interval until press the Follow Me button again. The air conditioner will cancel the Follow Me feature automatically if it does not receive the signal during any 7 minutes interval.

  2. LED Button
    Disable/Active indoor screen Display. When pushing the button, the indoor screen display is cleared, press it again to light the display.

Indicators on LCD

Information are displayed when the remote controller is powered up.

inventor O1MI 18B Air Conditioning Systems - Indicators on
LCD

Mode display

inventor O1MI 18B Air Conditioning Systems - Mode
display

| Displayed when data transmitted.
---|---
| Displayed when remote controller is ON.
| Battery display(low battery detection)
| Not available for this unit

ON Displayed when TIMER ON time is set.
OFF Displayed when TIMER OFF time is set.

Show set temperature or room temperature, or time under TIMER setting.

Displayed in Sleep Mode operation.
Indicated that the air conditioner is operating in Follow me mode
Not available for this unit
Not available for this unit

Fan speed indication

inventor O1MI 18B Air Conditioning Systems - Fan speed
indication

Note:
All indicators shown in the figure are for the purpose of clear presentation. But during the actual operation only the relative functional signs are shown on the display window.

How to use the buttons

inventor O1MI 18B Air Conditioning Systems - How to use the
buttons

Auto operation
Ensure the unit is plugged in and power is available. The OPERATION indicator on the display panel of the indoor unit starts flashing.

  1. Press the MODE button to select Auto.
  2. Press the UP/DOWN button to set the desired temperature. The temperature can be set within a range of 17ºC ~ 30ºC in 1ºC increments.
  3. Press the ON/OFF button to start the air conditioner.

NOTE

  1. In the Auto mode, the air conditioner can logically choose the mode of Cooling, Fan, and Heating by sensing the difference between the actual ambient room temperature and the setting temperature on the remote controller.
  2. In the Auto mode, you can not switch the fan speed. It has already been automatically controlled.
  3. If the Auto mode is not comfortable for you , the desired mode can be selected manually.

inventor O1MI 18B Air Conditioning Systems - How to use the buttons
2

Cooling /Heating/Fan operation
Ensure the unit is plugged in and power is available.

  1. Press the MODE button to select COOL, HEAT(cooling & heating models only) or FAN mode.
  2. Press the UP/DOWN buttons to set the desired temperature. The temperature can be set within a range of 17ºC~ 30ºC in 1ºC increments.
  3. Press the FAN button to select the fan speed in four steps- Auto, Low, Med,or High.
  4. Press the ON/OFF button to start the air conditioner.

NOTE
In the FAN mode, the setting temperature is not displayed in the remote controller and you are not able to control the room temperature either. In this case, only step 1, 3 and 4 may be performed.

inventor O1MI 18B Air Conditioning Systems - How to use the buttons
3

Dehumidifying operation
Ensure the unit is plugged in and power is available. The OPERATION indicator on the display panel of the indoor unit starts flashing.

  1. Press the MODE button to select DRY mode.
  2. Press the UP/DOWN buttons to set the desired temperature. The temperature can be set within a range of 17 ºC~ 30ºC in 1ºC increments.
  3. Press the ON/OFF button to start the air conditioner.

NOTE
In the Dehumidifying mode, you can not switch the fan speed. It has already been automatically controlled.

Adjusting air flow direction

Use the SWING ◀▶ & button to adjust the desired airflow direction.

  1. Up/Down direction can be adjusted with the button on the remote controller. Each time when you press the button, the louver moves an angle of 6 degree. If pressing more than 2 seconds ,the louver will swing up and down automatically.
  2. Left/Right direction can be adjusted with the button on the remote controller. Each time when you press the button, the louver moves an angle of 6 degree. If pressing more than 2 seconds ,the louver will swing up and down automatically.

NOTE: When the louver swing or move to a position which would affect the cooling or heating effect of the air conditioner, it would automatically change the swing/moving direction.

Timer operation
Press the TIMER ON button can set the auto-on time of the unit. Press the TIMER OFF button can set the auto-off time of the unit.

To set the Auto-on time.

  1. Press the TIMER ON button. The remote controller shows TIMER ON, the last Auto-on setting time and the signal “H” will be shown on the LCD display area. Now it is ready to reset the Auto-on time to START the operation.
  2. Push the TIMER ON button again to set desired Auto-on time. Each time you press the button, the time increases by half an hour between 0 and 10 hours and by one hour between 10 and 24 hours.
  3. After setting the TIMER ON ,there will be a one second delay before the remote controller transmits the signal to the air conditioner. Then, after approximately another 2 seconds, the signal “h” will disappear and the set temperature will re-appear on the LCD display window.

To set the Auto-off time.

  1. Press the TIMER OFF button. The remote controller shows TIMER OFF, the last Auto-off setting time and the signal “H” will be shown on the LCD display area. Now it is ready to reset the Auto-off time to stop the operation.
  2. Push the TIMER OFF button again to set desired Auto-off time. Each time you press the button, the time increases by half an hour between 0 and 10 hours and by one hour between 10 and 24 hours.
  3. After setting the TIMER OFF ,there will be a one second delay before the remote controller transmits the signal to the air conditioner. Then, after approximately another 2 seconds, the signal “H ” will disappear and the set temperature will re-appear on the LCD display window.

CAUTION!

  • When you select the timer operation, the remote controller automatically transmits the timer signal to the indoor unit for the specified time. Therefore, keep the remote controller in a location where it can transmit the signal to the indoor unit properly.
  • The effective operation time set by the remote controller for the timer function is limited to the following settings: 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 4.5, 5.0, 5.5, 6.0, 6.5, 7.0, 7.5, 8.0, 8.5, 9.0, 9.5, 10, 11, 12, 13, 14, 15,16,17, 18, 19, 20, 21, 22, 23 and 24.

Example of timer setting

TIMER ON
(Auto-on Operation)
The TIMER ON feature is useful when you want the unit to turn on automatically before you return home. The air conditioner will automatically start operating at the set time.

Example:
To start the air conditioner in 6 hours.

  1. Press the TIMER ON button, the last setting of starting operation time and the signal “H” will show on the display area.
  2. Press the TIMER ON button to display “6.0H ” on the TIMER ON display of the remote controller.
  3. Wait for 3 seconds and the digital display area will show the temperature again. The “TIMER ON” indicator remains on and this function is activated.

TIMER OFF
(Auto-off Operation)
The TIMER OFF feature is useful when you want the unit to turn off automatically after you go to bed. The air conditioner will stop automatically at the set time. Example:
To stop the air conditioner in 10 hours.

  1. Press the TIMER OFF button, the last setting of stopping operation time and the signal “H” will show on the display area.
  2. Press the TIMER OFF button to display “10H ” on the TIMER OFF display of the remote controller.
  3. Wait for 3 seconds and the digital display area will show the temperature again. The “TIMER OFF” indicator remains on and this function is activated.

COMBINED TIMER
(S both ON and OFF )etting timers simultaneously
TIMER OFF → TIMER ON
(On → Stop → Start operation)
This feature is useful when you want to stop the air conditioner after you go to bed, and start it again in the morning when you wake up or when you return home. Example:
To stop the air conditioner 2 hours after setting and start it again 10 hours after setting.

  1. Press the TIMER OFF button.
  2. Press the TIMER OFF button again to display
  3. 0H on the TIMER OFF display.
  4. Press the TIMER ON button.
  5. Press the TIMER ON button again to display 10H  on the TIMER ON display .
  6. Wait for 3 seconds and the digital display area will show the temperature again. The “TIMER ON OFF” indicator remains on and this function is activated.

TIMER ON → TIMER OFF
(Off → Start → Stop operation)
This feature is useful when you want to start the air conditioner before you wake up and stop it after you leave the house. Example:
To start the air conditioner 2 hours after setting, and stop it 5 hours after setting.

  1. Press the TIMER ON button.
  2. Press the TIMER ON button again to display 2.0H on the TIMER ON display.
  3. Press the TIMER OFF button.
  4. Press the TIMER OFF button again to display 5.0H on the TIMER OFF display .
  5. Wait for 3 seconds and the digital display area will show the temperature again. The “TIMER ON & TIMER OFF” indicator remains on and this function is activated.

Handling the remote controller

Location of the remote controller.

  • Use the remote controller within a distance of 8 meters from the appliance, pointing it towards the receiver. Reception is confirmed by a beep.

CAUTIONS

  • The air conditioner will not operate if curtains, doors or other materials block the signals from the remote controller to the indoor unit.
  • Prevent any liquid from falling into the remote controller. Do not expose the remote controller to direct sunlight or heat.
  • If the infrared signal receiver on the indoor unit is exposed to direct sunlight, the air conditioner may not function properly. Use curtains to prevent the sunlight from falling on the receiver.
  • If other electrical appliances react to the remote controller, either move these appliances or consult your local dealer.
  • Do not drop the remote controller. Handle with care.
  • Do not place heavy objects on the remote controller, or step on it.

Using the remote controller holder(optional)

  • The remote controller can be attached to a wall or pillar by using a remote controller holder(not supplied, purchased separately).
  • Before installing the remote controller, check that the air conditioner receives the signals properly.
  • Install the remote controller with two screws.
  • For installing or removing the remote controller, move it up or down in the holder.

Replacing batteries
The following cases signify exhausted batteries.
Replace old batteries with new ones.

  • Receiving beep is not emitted when a signal is transmitted.
  • Indicator fades away.

The remote controller is powed by two dry batteries (R03/LR03X2) housed in the back rear part and protected by a cover.

  1. Remove the cover in the rear part of the remote controller.
  2. Remove the old batteries and insert the new batteries,placing the(+) and (-) ends correctly.
  3. Install the cover back on.

NOTE: When the batteries are removed, the remote controller erases all programming. After inserting new batteries, the remote controller must be reprogrammed.
CAUTIONS

  • Do not mix old and new batteries or batteries of different types.
  • Do not leave the batteries in the remote controller if they are not going to be used for 2 or 3 months.
  • Do not dispose batteries as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.

All the pictures in the manual are for explanatory purposes only. The actual shape of the unit you purchased may be slightly different, but the operations and functions are the same. The company may not be held responsible for any misprinted information. The design and the specifications of the product for reasons, such as product improvement, are subject to change without any prior notice.
Please consult with the manufacturer at +30 211 300 3300 or with the Sales agency for further details. Any future updates to the manual will be uploaded to the service website, and it is advised to always check for the latest version.

inventor O1MI 18B Air Conditioning Systems - Qr codewww.inventorairconditioner.com/media- library

Scan here to download the latest version of this manual. www.inventorairconditioner.com/media- library

inventor logo

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals