- inventor EP3-WiFi16L HEPA Dehumidifiers
- SAFETY & WARNING INSTRUCTIONS
- ELECTRICAL INFORMATION
- SOCIABLE REMARKS ENVIRONMENTAL PROTECTION
- SAFETY PRECAUTIONS
- WARNINGS (for using R290 refrigerant only)
- Information on servicing
- Repairs to sealed components
- Repair to intrinsically safe components
- Cabling
- Detection of flammable refrigerants
- Leak detection methods
- Removal and evacuation
- Charging procedures
- Decommissioning
- Labeling
- Recovery
- STEPS BEFORE USE
- GETTING TO KNOW YOUR DEHUMIDIFIER
- CONTROL PANEL • FUNCTIONS
- WATER TANK & DRAIN HOSE
- MAINTENANCE & CLEANING
- STORAGE
- FREQUENTLY ASKED QUESTIONS & TROUBLESHOOTING
- Activate your Warranty
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
inventor EP3-WiFi16L HEPA Dehumidifiers
Specifications
- Models: EP3-WiFi16L, EP3-WiFi20L
- Language: English (EN)
- Intended Use: Domestic and small office use
- Features: Wi-Fi technology, quiet operation
Safety & Warning Instructions:
- No children under 8 should operate the dehumidifier.
- Provide supervision and do not leave minors unattended with the device.
- Keep the dehumidifier in an upright position at all times.
- Close all house exits where the device is operating.
- Always unplug the device before moving it.
- Empty the water tank when full or before storing the unit.
- Wait for 3 minutes after switching off and on before normal operation resumes.
- If abnormal sounds, odors, or smoke occur, disconnect the device.
Maintenance Instructions
- Avoid placing heavy objects on the power cord.
- Ensure the cord is not compressed or under obstacles.
- Avoid inserting objects into the unit’s air inlet and exhaust.
- Avoid operating or stopping the unit by switching the power supply on or off.
- Contact authorized service technician for repair or maintenance.
Moving Instructions
- Keep the device in a vertical position when moving it t another area.
- Ensure casters can move comfortably over obstacles, especially carpets.
- If tipped or misplaced, unplug immediately and ensure the unit is dry before use.
FAQ:
Q: What should I do if water leakage appears within the unit?
A: Turn the unit off, disconnect the power cord, and empty the water tank.
Ensure the unit is dry before resuming operation.
Dear Consumer,
Congratulations on your choice!
EVA ION PRO WIFI dehumidifier is distinguished among its class, by its
upgraded features and its remote access capability which allows the device to
be controlled from virtually anywhere. The Wi-Fi technology and the quiet
operation guarantee efficiency regarding humidity issues.
Please refer to this manual, to obtain full efficiency of the dehumidifier,
through the guidelines included in the following pages and make savings via
clever use of this device.
Please read all the safety instructions carefully before use and keep this instruction manual for future reference.
SAFETY & WARNING INSTRUCTIONS
- No children under the age of 8 should be permitted to operate this electric device. Be certain, that children, handicapped people, or people with the lack of knowledge and experience, must be supervised, depending the situation, by persons responsible for their well-being and do not undertake procedures such as the cleaning or the maintenance of this device.
- It is important that adequate supervision is provided and no minors are left unattended with this device.
- This dehumidifier is for domestic and small office use only. Do not use this device for commercial, industrial or marine use, and in areas with wet surfaces such as restrooms or shower rooms.
- This device should always be kept in an upright position to avoid any damage.
- All house exits (windows doors etc) where the dehumidifier is operating, should be shut.
- If water leakage appears within the unit, turn the unit off and disconnect the power cord.
- Before moving, unplug the device and manage to keep it in a vertical position in order to safely be transferred from one area to another.
- Be sure to empty the water whenever the water tank is full or when the device will not be used for a prolonged time.
- Always empty the water tank before storing the unit.
- When unit has been switched off and instantly switched on, keep in mind that, for operational reasons, there is a 3 minute delay in order to regain normal operation.
- If the unit is misplaced or tipped, unplug the power cord immediately. Make sure the unit is completely dry before resuming operation.
- Disconnect the device, if abnormal sounds, odors or smoke occur.
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons to avoid a hazard. Never attempt to dismantle, repair or modify the device.
- Do not attempt to repair, dismantle or modify this appliance. Contact your authorized service technician for repair or maintenance of this device.
- Do not operate or stop the unit by switching the power supply on or off.
- Do not insert any objects in the unit’s air inlet and exhaust as this may cause damage to the device.
- Do not place heavy objects on the power cord. Make sure that the cord is not compressed.
- Do not place cord under any obstacles (carpets rugs or runners etc). Cord should be arranged away from areas where accidental tripping may occur.
- Casters should be able to move comfortably over any obstacle. Be extra cautious while moving over carpets, since any extra force may cause the tipping of the unit, or the spilling of any water collected in the bucket.
- Do not sit or climb on the device.
- Do not place the unit in direct sunlight or near other heating sources.
- Do not use the unit near heat sources, chemicals, radiators, flammable materials or fire.
- Do not remove the water tank while the device is in use.
- Do not use the device without the filter. Dirt and lint may clog the unit thus reducing performance.
- Do not drink or use the collected water of the unit for any purpose.
- Do not use the unit with wet hands.
- Upon first use, and for proper calibration, please allow unit to operate continuously for 24 hours.
ELECTRICAL INFORMATION
The nameplate, with all the electrical and technical data of this appliance, is located on the rear panel.
-
The appliance should be installed in accordance with national wiring regulations.
-
Be sure the device is grounded properly. Proper grounding is important as it minimizes the chance of electric shock or fire. The power cord is equipped with a grounding
plug for protection against electric shock hazards. -
The device must be used in a properly grounded wall socket. If the specific socket you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper receptacle.
-
Ensure the wall socket is still accessible after the installation of the dehumidifier.
-
Do not use extension cords or adapter plugs with this device. Do not connect the dehumidifier to a multiple socket outlet, which is also being used for other electrical appliances.
-
To avoid personal injury, always disconnect the power supply of the device, before maintenance.
-
The unit’s circuit board (PCB) has an included safety fuse for overcurrent protection. You may find the specifications of the fuse, marked on the circuit board, for example: T 3.15A/250V (or 350V), etc.
Power off the dehumidifier before removing the plug.
SOCIABLE REMARKS ENVIRONMENTAL PROTECTION
Disposal of equipment no longer used:
Please follow the instructions below, when using this dehumidifier in European
countries.
- This appliance requires special treatment for disposal. In the European Union, electronic equipment must not be treated as domestic waste, but must be disposed of professionally in accordance with Directive 2002/96/EC of the European Parliament and Council of 27th January 2003 concerning old electrical and electronic equipment.
- The disposal of this unit should follow all legal requirements and should not be disposed as unsorted municipal waste.
- The hazardous substances can leak into the ground water supply thus entering the food chain, endangering your health and the environment.
- Fluorinated Greenhouse Gases are contained in hermetically sealed equipment. For specific information regarding the type the amount and the CO2 equivalent in tons, please refer to the relevant labels of the unit.
- There are several alternative solutions for disposal:
- Your local municipality has established free collection systems for electronic waste.
- Your local retailer upon purchase of a new product.
- The manufacturer may accept the old appliance for disposal.
- Old appliances sometimes contain valuable resources for scrap metal dealers.
SAFETY PRECAUTIONS
To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage.
- The seriousness is classified by the following indications.
Meanings of symbols used in this manual are as shown below.
- Never do this.
- Always do this.
WARNING
- Do not exceed the rating of the power outlet or connection device.
- Otherwise, it may cause electric shock or fire due to excess heat generation.
- Do not operate or stop the unit by switching on or off the power supply. It may cause electric shock or fire due to heat generation.
- Do not damage the power cord or use an unspecified power cord.
- It may cause electric shock or fire.
- Do not modify power cord length or share the outlet with other appliances It may cause electric shock or fire due to heat generation
- Do not insert or pull out plug with wet hands.
- It may cause electric shock.
- Do not place the unit near a heat source.
- Plastic parts may melt and cause a fire.
- Disconnect the power if strange sounds, smell, or smoke comes from it. It may cause fire and electric shock.
- You should never try to take apart or repair the unit by yourself. It may cause failure of machine or electric shock.
- Before cleaning, turn off the power and unplug the unit. It may cause electrical shock or injury.
- Do not use the machine near flammable gas or combustibles, such as gasoline, benzene, thinner, etc.
- It may cause an explosion or fire.
- Do not drink or use the water drained from the unit.
- It contains contaminants and could make you sick.
- Do not take the water bucket out during operation. Do not use extension cords.
CAUTION
- Do not use the unit in small spaces
- Do not place the device in areas where water may splash onto the unit.
- It may cause an electric shock or fire.
- Place the unit on a leveled and sturdy section of the floor.
- Do not cover the air intake or exhaust openings.
- A lack of air flow can lead to overheating and fire.
- ! Care should be taken when using the unit in a room with the following persons:
- Infants, children, elderly people, and people not sensitive to humidity.
- Do not use in areas where chemicals are handled.
- This will cause the unit deteriorate due to chemicals and solvents dissolved in the air.
- Never insert your finger or other objects into grills or openings. Take special care to warn children of these dangers.
- It may cause electric shock or failure of appliance.
- Do not place heavy object on the power cord and take care so that the cord is not compressed.
- There is danger of fire or electric shock.
- Do not climb or sit on the unit.
- You may be injured if you fall or the unit could be damaged.
- Always insert the air filters securely. Clean the air filters at least once every two weeks.
- Operation without filters may cause low performance and/or damage.
- If water enters the unit, turn the unit off and disconnect the power, contact a qualified service technician.
- Do not place flower vases or other water containers on top of the unit.
- Water may spill inside the unit, causing insulation failure and electrical Shock or fire
CAUTION
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. (be applicable for the European Countries )
- This appliance is not intended for use by persons (including children) with reduced physical ,sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.(be applicable for other countries except the European Countries )
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
- The appliance shall be installed in accordance with national wiring regulations.
- The appliance with electric heater shall have at least 1 meter space to the combustible materials.
- Contact the authorised service technician for repair or maintenance of this unit.
- Do not use the socket if it is loose or damaged.
- Do not operate your appliance in a wet room such as a bathroom or laundry room.
- Do not use this product for functions other than those described in this instruction manual
- Contact the authorised installer for installation of this unit.
- If the dehumidifier is knocked over during use, turn off the unit and unplug it from the main power supply immediately. Visually inspect the unit to ensure there is no damage. If you suspect the unit has been damaged, contact a technician or customer service for assistance.
- In a thunderstorm, the power must be cut off to avoid damage to the machine due to lightning.
- To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.
- Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.
- Do not open the unit during operation.
- When the air filter is to be removed, do not touch the metal parts of the unit.
- Do not operate the unit with damaged cord. Dispose the unit or return it to an authorized service facility for proper checking and/or repair.
- Hold the plug by the head of the power plug when taking it out.
- Electrical Information
- The manufactures nameplate is located on the rear or side panel of the unit and contains electrical and other technical data specific to this unit.
- Be sure the unit is properly grounded. To minimize shock and fire hazards, proper grounding is important. The power cord is equipped with a three-prong grounding plug for protection against shock hazards.
- Your unit must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker(the fuse or circuit breaker needed is determined by the maximum current of the unit. The maximum current is indicated on the nameplate located on unit), have a qualified electrician install the proper receptacle.
- Ensure the receptacle is accessible after the unit installation.
- Do not use extension cords or an adapter plugs with this unit. However, if it is necessary to use an extension cord, use an approved Dehumidifier extension cord only (available at most local hardware stores).
- To avoid the possibility of personal injury, always disconnect the power supply to the unit, before installing and/or servicing.
- All wirings must be performed strictly in accordance with the wiring diagram located on the middle baffle of the unit (behind the water bucket).
Take note the fuse specifications
The unit s circuit board (PCB) is designed with a fuse to provide overcurrent protection. The specifications of the fuse are printed on the circuit board, such as: T 3.15A/250V (or 350V), etc.
NOTE: All the pictures in the manual are for explanation purposes only. The actual shape of the unit you purchased may be slightly different, but the operations and functions are the same.
WARNINGS (for using R290 refrigerant only)
- Do not use any other means other than the recommended to expedite the defrosting process or to perform a cleaning of the unit, other than those recommended by the manufacturer.
- This device should never be stored in an area in combination with other ignition sources (for example: a gas appliance an electrical heater, open flames etc.)
- Do not attempt to penetrate the unit with a tool or try to burn
- Be extra cautious as refrigerant gas may be odorless.
- Appliance should be installed, operated and stored in a room with a floor area larger than 4m2.
- It is necessary to always comply with national gas regulations.
- Keep air ventilation clear of any obstructions
- The unit should be placed in storage in such a manner as to prevent any mechanical damage from occurring.
- Always operate this unit in a well-ventilated area, where the room size corresponds to the specifications of the device for optimal performance.
- Any persons involved with the operation and handling of the refrigerant circuit of this unit, should be certified by the related accredited industry, and authorized as competent to handle refrigerants, safely, and in accordance to the safety standards of the industry.
- Servicing should be performed only by a certified technician as per the Mnaufacturers recommendations. Any maintenance or repair required, should be performed by skilled personnel who are competent in the use of flammable refrigerants.
- The appliance should not be stored in a room with open flames (for example operating gas appliances such as stoves) and ignition sources ( such as electric heaters)
Description of displayed Symbols (*Only applicable to units with R290 Refrigerant)
Warnings (for using R290 refrigerant)
-
Transport of equipment containing flammable refrigerants
Determined by local regulations. -
Marking of equipment using signs
See local regulations -
Disposal of appliances supplied with flammable refrigerants
See National Regulations. -
Storage of equipment/appliances
The storage of equipment should be in accordance with the manufacturer’s instructions. -
Storage of packed (unsold) equipment
Storage package protection should be constructed such that mechanical damage to the equipment inside the package will not cause a leak of the refrigerant charge.
The maximum number of pieces of equipment permitted to be stored together will be determined by local regulations.
Information on servicing
-
Checks to the area
Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work in the system. -
Work procedure
Work shall be undertaken under a controlled procedure so as to minimize the risk of a flammable gas or vapor being present while the work is being performed. -
General work area
All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided. The area around the workspace shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material. -
Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, i.e. nonspeaking, adequately sealed or intrinsically safe. -
Presence of fire extinguisher
If any work is to be conducted on the refrigeration equipment or amy associated parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging area. -
No ignition sources
No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal, during which flammable refrigerant can possibly be released to the surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks.”No Smoking” signs shall be displayed. -
Ventilated area
Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere. -
Checks to the refrigeration equipment
Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt consult the manufacturer’s technical department for assistance.
The following check shall be applied to installations using flammable refrigerants:- the charge size is in accordance with the room size within which the refrigerant-containing parts are installed;
If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of any refrigerant. Any markings to the equipment must be visible and readable . Markings and signs that are unrecognizable must be corrected;
- the charge size is in accordance with the room size within which the refrigerant-containing parts are installed;
-
Checks to electrical devices
Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used . This shall be reported to the owner of the equipment so all parties are advised.
Initial safety checks shall include:- that capacitors are discharged; this shall be done in a safe manner to avoid possibility of sparking;
- that there no live electrical components and wring are exposed while charging, recovering or purging the system;
- that there is continuity of earth bonding.
Repairs to sealed components
During repairs to sealed components, all electrical supplies shall be
disconnected from the equipment being worked upon prior to any removal of
sealed covers, etc. If it is absolutely necessary to have an electrical supply
to equipment during servicing, then a permanently operating form of leak
detection shall be located at the most critical point to warn of a potentially
hazardous situation.
Particular attention shall be paid to the following to ensure that by working
in electrical components, the casing is not altered in such a way that level
of protection is affected. This shall include damage to cables, excessive
numble of connection, terminals not made to original specification, damage to
seals, incorrect fitting of glands, etc.
Ensure that seals or sealing materials have not degraded such that they no
longer serve the purpose of preventing the ingress of flammable atmospheres.
Replacement parts shall be in accordance with the manufacturer’s
specifications,
NOTE The use of silicon sealant may inhibit the effectiveness of some types of
leak detection equipment. Intrinsically safe components do not have to be
isolated prior to working on them.
Repair to intrinsically safe components
Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted for the equipment in use.
Cabling
Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other adverse environmental effects. The check shall also take into account the effects of aging or continual leaks. A halide torch (or any other detector using a naked flame) shall not be used
Detection of flammable refrigerants
Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks. A halide torch (or any other detector using a naked flame) shall not be used.
Leak detection methods
The following leak detection methods are deemed acceptable for systems
containing flammable refrigerants.
Electronic leak detectors shall be used to detect flammable refrigerants, but
the sensitivity may not be adequate, or may need re-calibrated.(Detection
equipment shall be calibrated in a refrigerant-free area.) Ensure that the
detector is not a potential source of ignition and is suitable for the
refrigerant used. Leak detection equipment shall be set at a percentage of the
LFL of the refrigerant and shall be calibrated to the refrigerant employed and
the appropriate percentage of gas(25% maximum )is confirmed .
Leak detection fluids are suitable for use with most refrigerants but the use
of detergents containing chlorine shall be avoided as the chlorine shall be
avoided as the chlorine may react with the refrigerant and corrode the copper
pipe work.
If a leak is suspected, all naked flames shall be removed/extinguished.
If a leakage of refrigerant is found which requires brazing, all of the
refrigerant shall be recovered from the system, or isolated (by means of shut
off valves) in a part of the system both before and during the brazing
process.
Removal and evacuation
When breaking into the refrigerant circuit to make repairs- or for any other purpose – conventional procedures shall be used. However, it is important that best practice is followed since flammability is a consideration. The following procedure
shall be adhered to:
- remove refrigerant;
- purge the circuit with inert gas;
- evacuate;
- purge again with inert gas;
open the circuit by cutting or brazing;
The refrigerant charge shall be recovered into the correct recovery cylinders.
The system shall be “flushed’ with OFN to render the unit safe. This process
may need to be repeated several times. Compressed air or oxygen shall not be
used for this task.
Flushing shall be achieved by breaking the vacuum in the system with OFN and
continuing to fill until the working pressure is achieved, then venting to
atmosphere, and finally pulling down to a vacuum. This processing shall be
repeated until no refrigerant is within the system. When the final OFN charge
is used, the system shall be vented down to atmospheric pressure to enable
work to take place. This operation is absolutely vital if brazing operations
on the pipe-work are to take place. Ensure that the outlet for the vacuum pump
is not close to any ignition sources and there is ventilation available.
Charging procedures
In addition to conventional charging procedures, the following requirements shall be followed.
- Ensure that contamination of different refrigerants does not occur when using charging equipment. Hoses or lines shall be as short as possible to minimize the amount of refrigerant contained in them.
- Cylinders shall be kept upright.
- Ensure that the refrigeration system is earthed prior to charging the system with refrigerant.
- label the system when charging is complete (if not already)
- Extreme care shall be taken not to overfill the refrigeration system.
Prior to recharging the system is shall be pressure tested with OFN. The system shall be leak tested on completion of charging but prior to commissioning. A follow up leak test shall be carried out prior to leaving the site.
Decommissioning
Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment and all its detail. It is recommended good practice that all refrigerants are recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall be taken is case analysis is required prior to re-use of reclaimed refrigerant. It is essential that electrical power is available before the task is commenced.
-
become familiar with the equipment and its operation.
-
Isolate system electrically.
-
Before attempting the procedure ensure that;
Mechanical handling equipment is available and being used correctly; the recovery process is supervised at all times by a competent person; recovery equipment and cylinders conform to the appropriate standards. -
Pump down refrigerant system, if possible.
-
If a vacuum is not possible , make a manifold so that refrigerant can be removed from various parts of the system.
-
Make sure that cylinder is situated on the scales before recovery takes place.
-
Start the recovery machine and operate in accordance with manufacturer’s instructions.
-
Do not overfill cylinders. (No more than 80% volume liquid charge).
-
Do not exceed the maximum working pressure of the cylinder, even temporarily.
-
When the cylinders have been filled correctly and the process completed, make sure that the cylinders and the equipment are removed from site promptly and all isolation valves on the equipment are closed off.
-
Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked.
Labeling
Equipment shall be labeled stating that it has been de-commissioned and emptied of refrigerant. The label shall be dated and signed. Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant.
Recovery
When removing refrigerant from a system, either for servicing or
decommissioning, it is recommended good practice that all refrigerant into
cylinders, ensure that only appropriate refrigerant recovery cylinders are
employed. Ensure that the correct number of cylinders for holding the total
system charge are available. All cylinders to be used are designated for the
recovered refrigerant and labeled for that refrigerant(i.e special cylinders
for the recovery of refrigerant). Cylinders shall be complete with pressure
relief valve and associated shut-off valves in good working order. Empty
recovery cylinders are evacuated and , if possible, cooled before recovery
occurs.
The recovery equipment shall be in good working order with a set with a set of
instructions concerning the equipment that is at hand and shall be suitable
for the recovery of flammable refrigerants.
In addition, a set of calibrated weighing scales shall be available and in
good working order. Hoses shall be complete with leak-free disconnect
couplings and good condition. Before using the recovery machine, check that it
is in satisfactory working order, has been properly maintained and that any
associated electrical components are sealed to prevent ignition in the event
of a refrigerant release. Consult manufacturer of in doubt.
The recovered refrigerant shall be returned to the refrigerant supplier in the
correct recovery cylinder, and the relevant Waste Transfer Note arranged. Do
not mix refrigerants in recovery units and especially not in cylinders.
If compressors or compressor oils are to be removed, ensure that they have
been evacuated to an acceptable level to make certain that flammable
refrigerant does not remain within the lubricant. The evacuation process shall
be carried out prior to returning the compressor to the suppliers. Only
electric heating to the compressor body shall be employed to accelerate this
process. When oil drained form a system, it shall be carried out safely.
STEPS BEFORE USE
-
A dehumidifier operating in a basement will have little or no effect in an adjacent enclosed storage area, such as a closet, unless there is adequate circulation of air in and out of the area. Do not use outdoors. This dehumidifier is intended for indoor residential use only.
Place the unit away from the clothes dryer, heater or radiator. Use the unit to prevent moisture damage anywhere books or valuables are stored. Use the dehumidifier in a basement to help prevent moisture damage. The dehumidifier must be operated in an enclosed area to be most effective. Close all doors, windows and other openings to the room. -
Upon initial use of the dehumidifier, operate the unit continuously 24 hours. Make sure the plastic cover on the continuous drain hose outlet is installed tightly to avoid possible leaks.
-
If the unit has been switched off and needs to be switched on again in a short period of time, allow approximately three minutes before acting as such.
-
Do not connect the dehumidifier to a multiple power socket outlet, which is also being in use with other electrical appliances.
-
Select a suitable location, making sure you have easy access to an electrical power outlet. Plug the unit into an electric socket-outlet with proper grounding.
-
Make sure the water bucket is correctly fitted otherwise the unit will not operate properly. NOTE: When the water in the bucket reaches a certain level, please be careful when moving the device to avoid accidental spilling.
-
Do not force casters to move over carpet surfaces, nor move the unit with full water in the bucket. (the unit may tip over and the water may spill)
Installation tips
- Do not block or restrict the airflow around the unit. Make sure the air inlet exhaust grills are not obstructed. Allow 20cm of clearance around the unit and 40cm above.
- Place the unit in an area where the temperature levels will not fall bellow 5ºC (41ºF) There is a possibility the coils will collect frost at temperatures that are under 5ºC (41ºF), which may result in low performance.(Working conditions: 5°C-32°C, 30%RH–80%RH).
- Ensure the filter is clean.
- Place unit in vertical operating position and allow 2 hours before initial use in order to avoid malfunctions.
- Prior to initial use, please remove the water bucket and check if any packaging parts (for example: the draining hose) are included. Remove and re-position the water bucket firmly into place.
Healthy Filters placement:
The dehumidifier that you have purchased includes two healthy filters inside
the packaging. One HEPA filter and one activated carbon filter. You can choose
to either use one or both of the healthy filters while operating the
dehumidifier.
- Remove the air intake grill.
- Attach the filters in the specially designed position on the center, making sure that the plastic grips are securing the two filters steadily. The placement order of the two filter is irrelevant.
- Once the filters are correctly placed, close again the air intake grill.
- The HEPA filter can improve the air quality in your space, as it helps to remove the suspended particles and reduces the possibility of allergies and diseases.
- The activated carbon filter helps to eliminate unpleasant odors, creating a clean atmosphere and ensuring that the indoor air in your space stays fresh.
GETTING TO KNOW YOUR DEHUMIDIFIER
CONTROL PANEL • FUNCTIONS
POWER
By pressing the “POWER” button the dehumidifier turns on or off. The “Power”
button and Display will turn on.
- When the set humidity is reached, the Energy Savings function is automatically activated during which the digital control display of the device may show increased humidity levels. This is because the fan is not operating. After the predetermined timeframe and if the humidity levels have increased, the device will resume dehumidification.
- In the event of a power failure the unit has an Auto Restart function. Once power is restored, the appliance will automatically restart at the preselected settings prior to the power failure.
MODE
By pressing the “MODE” button, various operations may be selected (Dryer,
Cont., Smart). While changing operation modes, device will make a short beep.
Dryer
Dryer mode: When this function is selected the device operates under Turbo Fan
Speed. After operating for approximately 2 hours the unit will check the
room’s humidity. If under 45%RH, only the fan will operate for two hours.
After the 2 hours, the unit will quit dryer mode. If over 45%RH, the unit will
operate in Turbo fan Speed for 1 hour before checking the room’s humidity
again. The maximum operation time set by this mode is 10 hours and can be
reduced depending on the room size and the dampness of the clothes.
- For drying clothes: place the dehumidifier in a small room and set nearby the clothes rack. Keep doors shut and allow the dehumidifier to dry the clothes.
- For optimal results manual wringing of the clothes is suggested.
- Allow 30-50cm distance from the moist clothes.
Cont.
Continuous function: the dehumidifier operates continuously when the drainage pipe is attached, or until the water tank is full, extracting humidity from the air. When this function is active the indicator will turn on and the device will work constantly, disregarding the relative humidity of the room and the desired humidity level set.
- For special humidity conditions where big amounts of condensation need to be extracted, such as extremely moist rooms.
Smart
Smart Dehumidification – The dehumidifier will set the humidity level between
45% to 55% according to the room’s temperature thus ensuring energy efficiency
and excellent room conditions.
While operating in this mode the manual humidity settings function is
unavailable.
Note: When none of the above MODE functions are selected (Dryer, Cont., Smart)
and all indication lights are off the desired humidity levels can be set
manually by pressing the PLUS (+) or MINUS (-) buttons.
PLUS (+) AND MINUS (-) CONTROL BUTTONS
Humidity Set Control Buttons
The humidity level can be set within a range of 35%RH (Relative Humidity) to 85%RH(Relative Humidity) in 5% increments each time one of the relative buttons are pressed, as long as no other modes (Dryer, Cont. or Smart) are selected.
- For drier air press the “Minus” (-) pad to set a lower percent value (%)
- For damper air, press the “Plus” (+) pad to set a higher percent value.
Note: Plus and minus buttons are inactive while Dryer or Cont or Smart modes are selected
FAN
Press the FAN button to select among the Low, Med or High fan speed.
- Silent mode: When activated the green indicator marked “Silent fan speed” is turned on. Select Silent Mode for quite operation in order to enjoy ideal conditions.
- Medium mode: When activated the green indicator marked “Med fan speed” will be turned on. Select this mode for normal operation.
- Turbo mode: When activated both indicators “Silent” and “Medium” are turned on. Select this mode when immediate dehumidification is necessary, such as areas or rooms that are unused for an extended period of time.
TIMER
Press the “TIMER” button to initiate the auto START or auto STOP function in
combination with the PLUS (+) and MINUS (-) buttons. The “TIMER” indicator and
the display will turn on.
- When unit is on, press the Timer button to activate the auto STOP function. When the unit is off, press this button to activate the auto START function.
- Press the (+) or (-) button to change the time by 0.5 hour increments, up to 10 hours or by 1 hour increments up to 24 hours. The control panel will then count down time remaining until START or STOP.
- The time selected will be stored within 5 seconds and the main display will automatically return to its previous state.
- When the auto START or auto STOP functions is set the Timer indicator is lit identifying that ON or OFF timers are programmed.
- Turning the unit ON or OFF at any time or changing the timers setting to 0.0 will terminate the Auto Start/Stop function.
- When the control panel window displays code “P2”, the Auto Start/Stop function will be terminated.
NOTE: The timer function can either be set to ON or OFF. Setting ON and OFF simultaneously is not possible.
ION
Press the “ION” pad to switch on or off the ionizer. Ions will be released in
the atmosphere to purify the air and remove unpleasant and unhealthy
particles. By pressing once again this function will be terminated.
Wi-Fi
Upon installation (initial) of the application Inventor Control, please make
sure that the dehumidifier is turned off. Press on the ION button for 3 to 5
seconds continuously, until the indication “AP” appears on the main display.
If pairing between the router and the unit is successful after a period of 8
minutes, the unit will exit Wi-Fi connection mode and the unit will enter all
previously set functions. If there is a failure in pairing within the 8minute
time-frame, the unit will automatically exit Wi-Fi connection mode.
Press the “ION” pad to switch on or off the ionizer. Ions will be released in the atmosphere to purify the air and remove unpleasant and unhealthy particles. By pressing once again this function will be terminated.
INDICATIONS
Bucket Full Indicator
Indicator “Full Water Tank” turns red following a beep alert when bucket is
full, removed, or misplaced.
The water level control switch shuts off the dehumidifier when the bucket is full, removed or misplaced
Auto Defrost
When frost builds up on the evaporator coils, the compressor will cycle off
and the fan will continue to run until the frost disappears. In this case the
display of the unit will show the P1 code.
This function not only ensures the safe and appropriate operation of the
dehumidifier but is also more efficient and economical in its performance
NOTE:
- When Auto Defrost is operating, the unit may cause some noise of the refrigerant fluids flowing, this is normal.
- Do not turn the dehumidifier off when auto defrost is operating.
WATER TANK & DRAIN HOSE
There are two ways to remove collected water. Before proceeding ensure that you have switched off and unplugged the unit.
-
Usage of the water
When unit is OFF and the tank of the dehumidifier is full, the full indicator will be lit, and the display will read P2. Additionally, when the unit is on and the tank is full, the compressor stops operation followed by the fan a few minutes later. The full indicator will flash and the display will show P2.- Slowly remove the bucket. Grip the handle with caution, and carefully pull outwards so the water does not overflow. Do not place the tank on the floor because the bottom of the tank is uneven. Doing so the tank will fall and the water will be spilled on the floor.
- Empty the water from the tank and place it again in to the device. The water tank, must be securely and properly placed, for the dehumidifier to operate.
- When the water tank is re-installed the unit will automatically restart.
- When you remove the tank, do not touch any parts inside the unit, as you may damage the device.
- Be sure to gently place the tank into the dehumidifier.
- Do not drink or use the collected water from the device.
- Wipe any excess water on, or in, the unit when removing the tank.
-
Continuous draining
Water automatically can be emptied into a floor drain by attaching the unit with a water hose.-
Remove the rubber plug located opposite the unit.
Insert the water hose into the drain outlet and make sure all connections are firmly tightened in order to avoid any possible leaks. -
The dehumidifier should be placed on a flat surface in an upright position.
-
Lead the water hose towards a suitable drainage facility and be certain that the water flows naturally. For correct drainage, make sure the hose stays below the level of the drain hose outlet.
-
When the continuous drainage feature is not being used, remove the drain hose from the drain hose outlet and re- install the rubber plug.
MAINTENANCE & CLEANING
Before performing any maintenance or cleaning of the dehumidifier, make sure that it is unplugged.
Cleaning the air filter:
Use water and mild detergent to clean the dehumidifier.
- Do not use abrasive cleaning agents or solvents; use a brush or vacuum attachments for cleaning
- Do not use a dishwasher to clean the filter.
- Do not apply any water directly on or into the device while cleaning, as it may cause rust, insulation deterioration or electrical shock.
- Allow the filter to completely dry before re-installing.
Cleaning the Hepa filter
The Hepa filter is located behind the air filter. It is recommended to clean
the HEPA filter every 30 days using a vacuum cleaner. The Hepa filter should
not be washed.
NOTE: This air filter is a thin mesh type filter, which is attached to the
inner-side of the removable air intake grill. There is no need for the air
filter to be replaced. Please clean following the mentioned steps above.
Cleaning the tank:
Partially fill the tank with clean water adding a minimal amount of mild
detergent. Clean thoroughly empty and rinse.
- Clean the tank every 2 weeks to prevent mold, mildew and bacteria growth.
- After cleaning, make sure the tank is placed back securely for the dehumidifier to operate.
NOTE: Both, the main body and the front of the unit, may be cleaned with a dry
cloth or with the usage of a cloth in combination with a mild dishwashing
detergent. Rinse thoroughly and wipe dry. It is advised to never use harsh
cleansers, wax or polish on the front side of this device.
Be certain to wipe around the controls with a dry cloth, as any excess water
in or around the controls may cause possible damage to the unit.
NEVER USE THE DEVICE WITHOUT THE AIR FILTER
STORAGE
When the unit is going to be stored for an extended period of time, please make sure you follow the instructions below, for the appropriate storage of your appliance:
- Turn the unit off allowing one day before storage, in order to allow the unit to drain properly.
- Remove the drain hose (if attached).
- Clean the removable parts of the device, water tank and air filter.
- Position and secure the power cord with its band opposite the dehumidifier.
- Cover the device.
- Store the dehumidifier in an upright position, in a dry and well ventilated area and avoid direct sunlight.
FREQUENTLY ASKED QUESTIONS & TROUBLESHOOTING
The unit does not start
-
Make sure the dehumidifier’s plug is placed completely into the socket.
-
Check the house fuse/circuit breaker box.
-
Check whether the power cord is damaged.
-
Check the water bucket, if it is full, empty it.
-
Check if the dehumidifier has reached its preset level.
-
Make sure the water bucket is positioned properly.
-
Room temperature is lower or higher than the advised operational range.
-
Check whether the humidity level has been set in high levels.
does not dry the air as efficient -
The humidity level is too high. Make sure that the dehumidifier has been operating enough time to remove the moisture.
-
Make sure there are no curtains, blinds or any other obstacles blocking the front or back of the dehumidifier.
-
The humidity selector may not be set low enough.
-
Make sure you have cleaned the filter as suggested. Clogged filter may result in reduced performance.
-
All house exits (windows doors etc) where the dehumidifier is operating, should be shut.
-
Room temperature is below the advised operational range.
-
There is a kerosene heater or other heating type, giving off water vapor in the room.
-
The room that the device is placed is bigger than suggested.
-
The unit makes a loud noise when operating
-
The air filter is clogged.
-
The device is tilted instead of being in an upright position.
-
The floor surface is not flat.
Frost build up on coils -
This is normal. This unit is supplied with an Auto defrost function. When the unit is operating in low temperatures it is expected that the Auto defrost will activate more often.
Drain hose water leakage
- Check the correct installation of the drain hose.
- Check for any blockage or damage of the drain hose Water on the Floor
- Check if the rubber plug is firmly placed. A loose plug may result to a possible water leak.
- Before removing the water bucket from the device allow a short period of time for any additional accumulated water to be drained.
Understanding Error and Protection codes
Error Codes:
- AS- Humidity sensor error– Power off unit and temporarily unplug allowing device to reset. If error persists, call for service.
- ES- Temperature sensor error– Power off unit and temporarily unplug allowing device to reset. If error persists, call for service.
- E3 – Unit malfunction– Power off unit and temporarily unplug allowing device to reset. If error persists, call for service.
- EC- Refrigerant leakage detection— Unit auto detects refrigerant leakage, if this occurs the EC code will appear. Power off unit and temporarily unplug allowing device to reset. If error persists, call for service.
Protection Code:
- P1 – Unit is defrosting– Allow the unit time to automatically defrost. The protection will clear after the unit self defrosts.
- P2 – The water tank is full or is not in the right position. Empty the water tank and replace it in the right position.
In the event of any of the above-mentioned malfunctions, turn off the unit, and check for any obstructions. Restart the unit, if the malfunction persists, turn off the unit and unplug. Contact the manufacturer or a qualified technician for service.
All the pictures in the manual are for explanatory purposes only. The actual
shape of the unit you purchased may be slightly different, but the operations
and functions are the same. The company may not be held responsible for any
misprinted information. The design and the specifications of the product for
reasons, such as product improvement, are subject to change without any prior
notice.
Please consult with the manufacturer at +30 211 300 3300 or with the Sales
agency for further details. Any future updates to the manual will be uploaded
to the service website, and it is advised to always check for the latest
version.
Scan here to download the latest version of this manual. www.inventorappliances.com/manuals
Activate your Warranty
Follow the next quick steps to activate your warranty:
-
STEP 1
Visit our website via the link:https://www.inventorappliances.com /warranty-card or by scanning the QR code, as follows: -
STEP 2
Fill in the obligatory fields as requested in the “Owner’s details” and “Unit’s details”: -
STEP 3
Click SEND button at the end of the submission form: -
STEP 4
Wait for the confirmation email you will receive at the email address you have filled in – p your spam folder. -
STEP 5
Inventor warranty is now valid!
Manufacturer: INVENTOR A.G. S.A.
24th km National Road Athens – Lamia & 2 Thoukididou Str., Ag.Stefanos, 14565
Tel.: +30 211 300 3300, Fax: +30 211 300 3333 –
www.inventor.ac