ASPIRE Digilock Touch Free RFID Smart Lock User Guide
- June 3, 2024
- aspire
Table of Contents
ASPIRE Digilock Touch Free RFID Smart Lock
ASSIGNED USE FUNCTIONALITY
Aspire Touch-Free RFID Smart Locks are operated by RFID Credential or by Mobile ID. The Digilink network application simplifies lock management, and admin and manager credentials allow for management access.
LOCK PARTS
Front Unit
Deadlatch Rear Unit
RFID Credentials
CREDENTIALS
-
User RFID Credential & Mobile ID1
-
Admin/Manager Credentials2
-
Network App
-
Power Jumper Key
Operates the lock| •| •| •|
---|---|---|---|---
Overrides user access| | •| •|
Allows management inspection
Remotely unlocks from any location| | •|
•
•
|
Programs admin and manager credentials to the lock| | | •|
Assigns user credentials (in assigned use functionality)| | | •|
Provides external power| | | | •
- An unlimited amount of user credentials may be assigned to each lock.
- An unlimited amount of admin and manager credentials may be programmed to operate locks
OPERATING INSTRUCTIONS
In assigned use functionality, users operate the lock with their assigned user credential(s) (either an RFID credential or Mobile ID credential).
Operate with an Assigned RFID Credential
Unlock: Present an assigned RFID credential.
Lock: Close the door.
Operate with an Assigned Mobile ID Credential
Unlock: Present an assigned Mobile ID credential.
Lock: Close the door.
Remote Unlock Using the Network App
Unlock: Locate the specific lock that you wish to remotely unlock on the
hardware list within the Network app. Toggle the switch next to the lock name
to unlocked. Present hand to the lock interface to unlock.
Lock: Close the door.
SUPPORT
Error Condition Indicators
10 rapid beeps:
The lock is binding which means that either door alignment or stored items are
preventing the lock from operating. Press on the door while operating the
lock. If error condition persists, contact Digilock support for assistance.
2 sets of three beeps:
The batteries are low. Replace the batterie
Does Not Unlock with an RFID Credential or Mobile ID
The lock does not recognize the RFID credential or Mobile ID. For immediate access, operate with a valid Admin or Manager credential. Follow instructions to Assign User Credential(s) located in the network setup guide, to assign the user to the lock.
Does Not Operate with an Admin or Manager Credential
The lock does not recognize the Admin or Manager credential. Follow instructions to Add Admin or Manager credentials located in the network setup guide. For immediate access, operate with another valid Admin or Manager credential, or with the network app.
Does Not Operate with the Network App
The lock may have not been added to the network. Follow the “Add Lock” instructions located in the network setup guide, to add the lock to the network, if the lock if still non-functional with the network app after following those instructions, contact Digilock support for additional assistance.
No Audible Feedback or LED
- The batteries may need to be For immediate access, operate with the Network App or a Power Jumper key.
- The front unit may not be properly connected to the rear Remove the lock from the door and check the connection.
USING POWER JUMPER KEY
Insert the Power Jumper key into the key slot. A two-tone beep will be heard
and the LED will turn on.
While the key is inserted, present a valid Admin or Manager RFID credential or
present a valid Admin or Manager Mobile ID credential to access the lock.
After gaining access to the lock, change the batteries as soon as possible.
The batteries are located in the rear unit of lock
BATTERY REPLACEMENT
It is not necessary to remove the lock from the door. In case of battery
failure while the door is locked, operate with a Power Jumper key.
CAUTION: Risk of explosion or leakage if battery is replaced by an
incorrect type, mixed with a different battery type, or inserted backwards.
Replace all batteries of a set at the same time. Be sure to insert batteries
with correct polarities. Remove exhausted batteries from product promptly and
dispose of used batteries according to the battery manufacturer’s
instructions.
Remove the screw from the Cover Plate with a Phillips head screwdriver. Remove the Cover Plate by lifting the tab at the edge of the cover, below the arrows.
Remove the batteries from the housing. Replace with four premium alkaline AA batteries. Dispose or recycle used batteries according to local regulations.
Replace the Cover Plate and secure with the screw.
FCC Statement
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/
TV technician for help.
Caution: Any changes or modifications to this device not explicitly approved
by manufacturer could void your authority to operate this equipment. This
device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference,
and (2) this device must accept any interference received, including
interference that may cause undesired operation.
RF Exposure Information This equipment complies with FCC radiation exposure
limits set forth for an uncontrolled environment. This equipment should be
installed and operated with minimum distance 20cm between the radiator and
your body.