ILuminar 1000W 208-277V Lighting CMH Fixture IL-CMHDE1000-240 User Manual
- June 8, 2024
- ILuminar
Table of Contents
- WARNINGS
- 1000W DE FIXTURE
- INSTALLATION PROCEDURE
- PERFORMANCE REQUIREMENTS
- COMPATIBILITY
- DIMMING
- HOT RESTRIKE
- MOUNTING LOCATION
- BALLAST PROTECTIONS
- PHYSICAL SPCIFIC
- CARE
- FIXTURE DIAGRAM
- PROTECTIONS
- WIRING DIAGRAM
- TOUCH CONTROLLER DAISY CHAIN DIAGRAM
- HASH CONTROLLER DAISY CHAIN DIAGRAM
- TROUBLESHOOTING
- RETURNS WARRANTY
- CERTIFICATIONS
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ILuminar 1000W 208-277V Lighting CMH Fixture IL-CMHDE1000-240
THANK YOU for purchasing an ILUMINAR Lighting CMH FIXTURE. We strive
to deliver the best customer service alongside world-class products and we go
above and beyond to make sure you are satisfied with your purchase. The
following is a general set of warnings and basic guidelines for the ILUMINAR
CMH DE Fixture. Always have an expert install your product(s).
KEEP ORIGINAL PACKAGING
In the event of a return, products will need to be in the original ILUMINAR
packaging to avoid product damage during shipping. Any damage to products not
in their original packaging will not be covered under the Warranty. Visit
iluminarlighting.com/warranty for
more detailed information.
SAFETY 1ST
FAILURE TO OBSERVE THE FOLLOWING WARNINGS COULD RESULT IN ELECTRICAL SHOCK AND
SERIOUS INJURY. Additionally, failure to follow these safety warnings can/will
result in a void of all warranties as well as any manufacturer liability.
Please read carefully prior to beginning installation.
WARNINGS
- Make sure the power cord is correctly connected and the lamp is securely in place.
- Disconnect the fixture from the power supply prior moving the unit or performing any maintenance or lamp changes.
- DO NOT open the ballast case, it will void the warranty.
- DO NOT support the ballast by power cord(s). These cords/connections are not designed to bear weight.
- DO NOT make contact with the interior of the socket while power is on.
- DO NOT attempt to rewire, alter, modify or reconfigure your system – this will void the ILUMINAR warranty and could create serious safety hazards, or cause bodily injury or death, as this is a high amperage and voltage device.
- DO NOT submerge in water.
- DO NOT plug the system into untested or unidentified voltage other than what is designated on ballast.
- DO NOT CONNECT A CMH BALLAST to a Flip Box. It will void the warranty and can cause electrical failure within the CMH Ballast. Flip or Switch Boxes are not recommended for any CMH Units or for any high wattage ballasts.
- DO NOT plug or unplug the lamp cord while the ballast is connected to power.
- Make sure to wear proper gloves to protect from the transfer of oil from the skin to the lamps glass surface.
- When changing out the lamp, make sure that the lamp has time to cool before touching.
- Make sure the lamp is correctly locked into the socket, properly securing the lamp.
- If the lamp is damaged in any way (cracked, loose internal connections) replace the lamp immediately.
- Keep away from Children. This product contains delicate electronic components. If it is placed near an object that transmits radio signals, it could cause interference (i.e.: mobile devices, walkie talkies, CB radios, remote controls and microwaves). If interference occurs, move such objects away from the appliance.
1000W DE FIXTURE
- Energy efficient
- Uniform Light Distribution
- Soft Start Technology
- Ignition Failure Protection
INPUT SPECIFICATIONS 208V 240V 277V
Input Current: 5.10A: 4.60A: 3.85A
Input Power: 1045W
Rated Main Voltage: 208-277V
Voltage Range: 187-290V
Ignition Voltage: 5kV
Dimming Type: Gear / 945 / 1000 / EXT
THD: <15%
Controller: 0 -10V
Min Power Factor: 0.95
Crest Factor: 1.7
Input Connection: IP68 Wieland Plug
Main Frequency: 50 – 60Hz
Operation frequency: 140-220HZ
Relative Humidity: 95% (Non-condensing)
Max Allowable Case Temperature: 75°C/167°F
Ambient Temperature: -20…+40°C / -4…+104°F
Recommended Lamp: ILUMINAR CMH 1000W DE
Socket TypeLamp Base: K12x30s – / Style
Mounting Height: 1.2m / 4′
MOUNTING & COVERAGE
PLEASE READ CAREFULLY PRIOR TO INSTALLATION
INSTALLATION PROCEDURE
When possible, have a licensed electrician or electrical expert install all
fixtures or aid in the electrical layout plans and/or diagrams prior to
installation.
Check the electrical panel to ensure proper voltage is available for the
number of fixtures installed. Panels should only support a total amperage of
80% of its capacity. (100 amp panel should never exceed 80 amps).
- Find a suitable location for the fixture with sufficient cooling and away from heat sources.
- Use the included hanging cables to hang the fixture.
- Ensure the fixture is hung completely level to the ground. A fixture that is not level can burn the lamp emitter incorrectly leading to shorter lamp life, poor lamp performance and/or lamp failures.
- Install the lamp into the roll-lock socket (instructions pages 6-7) using soft cotton or surgical gloves.
- Plug the power cord into the power source (electrical outlet).
- For proper lamp break-in, we recommend that you run the fixture at 100% power for at least 100 straight hours after initial startup. This will improve lamp life and performance.
- Set your desired dimming ratio. NOTE: the ballast dims or raises output gradually to protect the lamp, so you may not see an instant increase upon changing your output percentage.
PERFORMANCE REQUIREMENTS
RATED MAINS VOLTAGE: 208-277V
VOLTAGE RANGE: +/- 10% 187-290V
MAINS FREQUENCY: 50 – 60Hz
OPERATIONS FREQUENCY: 140-220HZ
COMPATIBILITY
Compatible with all ILUMINAR CMH DE lamps & CMH DE lamps as well as the ILUMINAR Touch & ILUMINAR HASH Environment controllers.
DIMMING
- Turn the dimming dial to cycle through the dimming levels.
- If your lamp fails to start immediately, DO NOT cycle the power on and off. This can damage the lamp and ballast.
- If after 30 minutes your lamp is still not lit, shut off power to the ballast, and reconnect.
- This will begin the startup sequence again.
- Until the lamp has achieved at least 100 hours of operation, the lamp should never be turned off prior to running at least 15 minutes. In case this happens, WAIT 1 hour before igniting the lamp again.
HOT RESTRIKE
IT IS VERY IMPORTANT that the lamp is given adequate time to cool down before it is reignited. Allow a hot lamp to cool for 1 hour before you try to restrike it. Hot re-strikes cause permanent lamp failure and lumen output degradations. The lamp should never be turned off before the lamp reaches full intensity, this may shorten its lifespan.
MOUNTING LOCATION
DO NOT install fixtures in areas of high heat, such as an attic, tent or closed closet. Mount units at least 24-60 inches apart.
BALLAST PROTECTIONS
- End of Lamp Life (EOL) Protection
- Short Circuit Protection
- Open Circuit Protection
- Ignition Failure Protection
- Thermal Protection
- Suitable for ILUMINAR Touch Controller & HASH Controller
- Suitable for HASH Controller / 0-10V Control
- Total Control Range 50-115%
PHYSICAL SPCIFIC
CASE LENGTH: 564mm: 22.22”
CASE WIDTH: 249mm: 9.80”
HEIGHT: 601mm: 23.66”
WEIGHT: 6.6kg: 14.55 lbs
CARE
- Max. allowable case temperature: 75º C / 167º F
- Ambient Temperature: -20º to +40º C / -4 to +104º F
- Max. Humidity: 95%
- Ignition Voltage: 5kV
FIXTURE DIAGRAM
PROTECTIONS
Microprocessor Driven
End of Lamp Life (EOL)
Open Circuit Protection
Ignition Failure Protection
Thermal Sensing Protection
WIRING DIAGRAM
NAME VOLTAGE SKU DIAGRAM
Power Cord Wieland Female to Male 120V IL-WLDCRD-120V:
Power Cord Wieland Female to Male 240V IL-WLDCRD-240V:
Power Cord Wieland Female to Male 277V IL-WLDCRD-277V:
Power Cord Wieland Female to Male 347V IL-WLDCRD-347V:
RJ14 Controller Connection
Wieland Female
Wieland Male
TOUCH CONTROLLER DAISY CHAIN DIAGRAM
-
RJ14-RJ14 5ft / 1.5m
SKU: IL-CB-RJ914
RJ14-RJ14 10 ft / 3m
SKU:IL-CCRD-RG14-10 -
RJ14 Splitter
SKU: IL-CCRD-RG14-10
HASH CONTROLLER DAISY CHAIN DIAGRAM
-
RJ9-RJ14
Include it -
RJ14-RJ14
SKU: IL-CB-RJ1414 -
RJ14 Splitter
SKU: IL-ADPT-SPLIT
TROUBLESHOOTING
Follow these troubleshooting solutions:
Possible Cause: Corrective Maintenance
Lamp Loose in Socket: Ensure the lamp is fully inserted into the socket
and that it has been properly locked.
Incorrect Voltage: Make sure you’re using the correct input voltage with
ballast. If using incorrect voltage, disconnect the ballast from the power
source immediately.
Defective or Improper Wiring: Examine wiring to ensure it agrees with
wiring diagrams on ballast label. Check connections to see that they are
secure. If wiring a ballast, DO NOT use a neutral. The correct wiring is two
hot wires and a ground.
Poor electrical connections: Check wiring and lamp contact with socket.
Incorrect Lamp: Verify that you’re using a correct wattage lamp.
Lamp Damage: Investigate possibility of outer lamp damage. Look for
broken tubes or loose metal replace lamp.
RETURNS WARRANTY
Please contact your point of purchase store for returns.
When properly used, this unit will provide you with years of service. The
ballast is covered under a 3 year warranty and the lamp has a 1 year warranty.
This warranty will be voided if the unit is misused, abused, opened or
altered. Warranty repair or replacement will be at the sole discretion of the
manufacturer.
Defective units need to be returned to the place of purchase with proof of
purchase/receipt.
CERTIFICATIONS
For more warranty information, visit iluminarlighting.com/warranty
This guide does not supersede national, state, or local regulations for electrical installations.
ILuminar 1000W 208-277V Lighting CMH Fixture IL-CMHDE1000-240 User Manual –
Optimized PDF
ILuminar 1000W 208-277V Lighting CMH Fixture IL-CMHDE1000-240 User Manual –
Original PDF
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>