ILUMINAR iLW 2.5 40W IL-4025FSG-120 Single X-Wide 47 Inch FS Grow Light User Manual
- June 6, 2024
- ILuminar
Table of Contents
- ILUMINAR iLW 2.5 40W IL-4025FSG-120 Single X-Wide 47 Inch FS Grow Light
- Please read this manual thoroughly prior to installing or operating the
- TECHNICAL SPECS
- VOLTAGE AND AMPERAGE
- PHYSICAL SPECS
- HARDWARE AND ACCESSORIES
- IN THE BOX
- HANGING INSTALLATION
- MOUNTING INSTRUCTIONS
- ADDITIONAL ACCESSORIES
- PRECAUTIONS
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ILUMINAR iLW 2.5 40W IL-4025FSG-120 Single X-Wide 47 Inch FS Grow Light
Please read this manual thoroughly prior to installing or operating the
ILUMINAR iLW
- Observe all safety precautions (see page 10), seek the services of a qualified electrician, installation professional, or call ILUMINAR Lighting technicians for assistance.
- DO NOT handle or touch the fixture while in use.
- Connect the fixture only to the power sources of the appropriate voltage using the correct AC plug type. Protect power cables from being pinched, walked on, or otherwise damaged. Be especially careful where the power cable enters the power outlet to the unit. Only connect the fixture to an electrical outlet or extension cord of comparable standard and level rating. Connect the fixture ONLY to the power sources of the correct voltage using the plug received.
- The fixture should only be cleaned as directed. Always seek service for your system by qualified service personnel if any of the following occur:
- The fixture shows a noticeable change in performance.
- The power-supply cord or plug is damaged.
- The fixture has been dropped, or the exterior is damaged.
TECHNICAL SPECS
PPF | 100 µmol/s | 150 µmol/s | 200 µmol/s |
---|---|---|---|
BTU | 136 | 204 | 272 |
Emitter Type | Multiple Spectrum LED Diodes | ||
Efficacy | 2.5 µmol/J | ||
Minimum Mounting Height | 6-12” to top of Canopy | ||
Emitter Cooling | Passive / Extruded Case | ||
Waterproof Rating | IP65 for Damp/Wet Conditions | ||
LED Lifespan (90%) | 55,000+ hours | ||
Power Factor | > 90% | ||
Ambient Temperature | 0 – 35°C / 32-95°F | ||
Color Temperature | 4000k | ||
Relative Humidity | 98% | ||
Frequency | 50 / 60Hz | ||
THD | < 20% | ||
Color Rendering Index | 88 | ||
Min. Power Factor | 0.9 | ||
Crest Factor | 0.99 |
VOLTAGE AND AMPERAGE
120V | 0.36A | 42W | 0.53A | 62W | 0.69A | 82W |
---|---|---|---|---|---|---|
208V | 0.20A | 41W | 0.30A | 61W | 0.40A | 81W |
240V | 0.18A | 40W | 0.27A | 60W | 0.36A | 80W |
PHYSICAL SPECS
Height | 29mm / 1.14” | 29mm / 1.14” | 29mm / 1.14” |
---|---|---|---|
Width | 130mm / 5” | 130mm / 5” | 130mm / 5” |
Length | 1200mm / 47.2” | 1200mm / 47.2” | 1500mm / 59” |
Weight | 2.2lbs/1kg | 2.2lbs/1kg | 2.75lbs/1.13kg |
HARDWARE AND ACCESSORIES
The iLW LED fixture can be hung from steel cables or can be mounted to a rack.
Before you begin installation, check that you have all the necessary parts to
begin.
IN THE BOX
- iLW Fixture
- 2 Metal Clips for Hanging Cables
- 2 Screws for Clips & Hanging Cables
- 2 Steel Hanging Cables with Cylindrical Lock
- 4 Screws & 4 Anchors
HANGING INSTALLATION
- Loop the steel cables over the beam, feeding the wire through its loop and letting the cylindrical lock hang.
- Using the provided screw, attach the clip to the steel cable’s cylindrical lock.
- Snap the clips onto the light bar’s heat sink.
- Adjust the spacing of the clips as needed.
- Pull the steel cable down through the cylindrical lock to adjust the fixture height.
To shorten cable: Press the cable down through the cylindrical lock. (Figure A) To extend cable: Press metal top down and pull up on cable. (Figure B)
MOUNTING INSTRUCTIONS
- Drill 4 holes into an overhead structure or rack. Insert the provided mounting anchors into the holes and screw the metal clips directly into the anchors.
- Drill 4 holes into an overhead structure or rack. Insert the provided mounting anchors into the holes and screw the metal clips directly into the anchors.
ADDITIONAL ACCESSORIES
iLW Power Hub
If you use more than one iLW in your grow room or clone rack, save space by
adding in the iLW Power Hub. The hub comes as a dual-, tri- or quad-connector
that will send power to each of your iLW fixtures without the need of
additional outlets.
When using the LW Dual/Tri/Quad Power Hubs for daisy-chaining fixtures, the
max load at 120V is 400W Power and at 277V is 800W power.
PRECAUTIONS
Please read the following list carefully prior to beginning installation.
- Leave at least one inch of space between the fixture and the mounting area for maximum performance and lifespan.
- ALWAYS wear protective eyewear when looking directly at the diodes to prevent eye damage.
- Only handle, clean or move fixture when it’s unplugged and completely cool.
- Keep the fixture free of dust, debris, and deposits to ensure the maximum potential of the fixture.
- NEVER use a cloth to clean the diodes. This can scratch the diodes and could potentially break or dislodge them.
- DO NOT use chemicals to clean the fixture. Use ONLY low pressure air or low pressure water to remove dust and debris.
- DO NOT exceed 70% max load for breakers due to inrush current in LED fixtures
GUARANTEE
At ILUMINAR, we stand behind our products and our technology as well as our
customers. All ILUMINAR LED fixtures are backed by our 5-Year Guarantee.
Please visit our website iluminarlighting.com/warranty for more information.
1-877-540-5588 iluminarlighting.com
References
- Led Grow Lights | Iluminar Lighting | Led Grow Lights | Canada
- TERMS AND CONDITIONS | ILUMINAR Lighting
Read User Manual Online (PDF format)