ILUMINAR iL1 530W Greenhouse LED Grow Light User Manual

June 5, 2024
ILuminar

USER MANUAL
iL1 530W
iL1 660W IL-A153026-FSG-120
IL-A166026-FSG-120
1-877-540-5588
iluminarlighting.com
[email protected]

Please read this manual thoroughly prior to installing or operating the ILUMINAR iL1.

  • Observe all safety precautions (see page 12), seek the services of a qualified electrician, or installation professional, or call ILUMINAR Lighting technicians for assistance.
  • DO NOT handle or touch the fixture while in use.
  • Connect the fixture only to the power sources of the appropriate voltage using the correct AC plug type. Protect power cables from being pinched, walked on, or otherwise damaged. Be especially careful where the power cable enters the power outlet to the unit. Only connect the fixture to an electrical outlet or extension cord of comparable standard and level rating. Connect the fixture ONLY to the power sources of the correct voltage using the plug received.
  • The fixture should only be cleaned as directed. Always seek service for your system by qualified service personnel if any of the following occur:
    1. The fixture shows a noticeable change in performance.
    2. The power-supply cord or plug is damaged.
    3. The fixture has been dropped, or the exterior is damaged.

TECHNICAL SPECIFICATIONS

MODEL: 2.6  VOLTAGE: 100-277V
WATTS: 530W SKU: IL-A153026-FSG-120
660W           IL-A166026-FSG-120

TECHNICAL SPECS 530W 660W
PDF 1378 µmol/s 1716 µmol/s
Heat Output (BTU/h) 1802 2244
Efficacy 2.6 µmol/J
Power Factor >0.9
THD <20%
Crest Factor 0.99
Rated Voltage 120-277V AC
Voltage Range 100-277V
Frequency 50 / 60Hz
Dimmable 0-10V Controllable
Ambient Temperature 0 – 35°C / 32-95°F
Relative Humidity 98%
Color Temperature 4000k
Color Rendering Index 88
Minimum Mounting Height >18” to top of Canopy
Emitter Cooling Passive Thermal Management
Light Distribution +/- 5% 125º
Waterproof Rating iP65 for Damp/Wet Conditions
--- ---
LED Lifespan (90% of Life) >54,000 hours

iL1 LED SPECTRUM

VOLTAGE AND AMPERAGE

530W 660W
120V 4.52A
208V 2.58A
240V 2.24A
277V 1.93A
347V 1.56A
480V 1.12A

MOUNTING & COVERAGE

PHYSICAL SPECIFICATIONS

530W 660W
Length 1140mm / 44.9”
Width 129mm / 5.1“
Height 200mm / 7.9”
Weight 10.2 Kg / 22.5 lbs

HARDWARE AND ACCESSORIES

The iL1 can be hung from steel cables or can be mounted to a rack. Before you begin the installation, check that you have all the necessary parts to begin.
IN THE BOX

  1. iL1 Fixture
  2. Power Supply
  3. Hooks

HANGING INSTALLATION

  1. Set the hooks on the beam.
  2. Hang the light into hooks.

CONNECTION

If you plan to utilize several LEDs in your room or facility, one of the many benefits of the ILUMINAR LED is that you can “daisy chain” one fixture to another to save space and use only one outlet to run several lamps, thus minimizing the number of cords used in your space.
If you plan to utilize the ILUMINAR HASH Controller, connect the connections from the controller to the fixture and then connect the Daisy Chain Controller Cable from fixture to fixture. Please consult with our lighting layout designers to ensure the proper spacing of outlets for your unique setup.

AVAILABLE CABLES

PPFD MAP

(530W)
IL-A166026-FSG-120

PPFD MAP iL1 530W at 1.5ft

Clearance 1.5 ft
Qty 1 u
Average PPFD 562.14 μmol/m2/s
Max PPFD 1171 μmol/m2/s
Min PPFD 164 μmol/m2/s
Median PPFD 476.5 μmol/m2/s
Min/Average 29.17 %
Watts 557.7 W

Legend

PPFD MAP iL1 530W at 4ft

Clearance 4 ft
Qty 1 u
Average PPFD 203.39 μmol/m2/s
Max PPFD 256 μmol/m2/s
Min PPFD 146 μmol/m2/s
Median PPFD 202.5 μmol/m2/s
Min/Average 71.78 %
Watts 557.7 W

Legend

(660W)
IL-A153026-FSG-120

PPFD MAP iL1 660W at 1.5ft ****

Clearance 1.5 ft
Qty 1 u
Average PPFD 626.34 μmol/m2/s
Max PPFD 119 5 μmol/m2/s
Min PPFD 183 μmol/m2/s
Median PPFD 532 μmol/m2/s
Min/Average 29.22 %
Watts 661.2 W

Legend

PPFD MAP iL1 660W at 4ft

Clearance 4 ft
Qty 1 u
Average PPFD 252.1 μmol/m2/s
Max PPFD 320 μmol/m2/s
Min PPFD 172 μmol/m2/s
Median PPFD 251 μmol/m2/s
Min/Average 68.23 %
Watts 661.2 W

Legend

CAUTION

  1. Leave at least one inch of space between the fixture and the mounting area for maximum performance and lifespan.
  2. ALWAYS wear protective eyewear when looking directly at the diodes to prevent eye damage.
  3. Only handle, clean, or move fixtures when it’s unplugged and completely cool.
  4. Keep the fixture free of dust, debris, and deposits to ensure the maximum potential of the fixture.
  5. NEVER use a cloth to clean the diodes. This will scratch the diodes and could potentially break or dislodge them.
  6. DO NOT use chemicals to clean the fixture. Use ONLY low-pressure air or low-pressure water to remove dust and debris.
  7. Do NOT use sulfur vaporizers.

5 YEAR WARRANTY
GUARANTEE

At ILUMINAR, we stand behind our products and our technology as well as our customers. All ILUMINAR fixtures are backed by our 5-Year Guarantee. Please visit our website iluminarlighting.com/warranty for more information.

1-877-540-5588
iluminarlighting.com
[email protected]

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ILuminar User Manuals

Related Manuals