ILUMINAR iLogic8 UV+Far Red 30W 120-277V LED Fixture User Manual

October 27, 2023
ILuminar

ILUMINAR iLogic8 UV+Far Red 30W 120-277V LED Fixture

ILUMINAR iLogic8 UV+Far Red 30W 120-277V LED Fixture

Please read this manual thoroughly prior to installing or operating the ILUMINAR iLOGIC8

  • Observe all safety precautions (see page 10), seek the services of a qualified electrician, installation professional, or call ILUMINAR Lighting technicians for assistance.
  • DO NOT handle or touch the fixture while in use.
  • Connect the fixture only to the power sources of the appropriate voltage using the correct AC plug type. Protect power cables from being pinched, walked on, or otherwise damaged. Be especially careful where the power cable enters the power outlet to the unit. Only connect the fixture to an electrical outlet or extension cord of comparable standard and level rating. Connect the fixture ONLY to the power sources of the correct voltage using the plug received.
  • The fixture should only be cleaned as directed. Always seek service for your system by qualified service personnel if any of the following occur:
    1. The fixture shows a noticeable change in performance.
    2. The power supply cord or plug is damaged.
    3. The fixture has been dropped, or the exterior is damaged.

TECHNICAL SPECS

Rated Voltage 120-277V AC
Voltage Range (+/-10%) 100-277V
Min Power Factor 0.95
THD < 20%
Crest Factor 1.5
BTU 1200
Frequency 50 / 60Hz
Dimmable 0-10V
Ambient Temperature 0 – 35°C / 32-95°F
Max. Temperature 35°C / 95°F
Relative Humidity 85%
Color Temperature 3350k
Color Rendering Index 87
Minimum Mounting Height 8-12” to top of Canopy
Emitter Cooling Passive / Extruded Case
Light Distribution 120º
Waterproof Rating IP66 for Damp/Wet Conditions
LED Lifespan (90% of Life) 50,000+ hours

PHYSICAL SPECIFICATIONS

Length 1064mm 41.9″
Width 1002mm 39.4″
Height 124.3mm 4.9″
Weight 22.8kg 50.3lbs

VOLTAGE AND AMPERAGE

120V 5.7A 652W
208V 3.2A 632.5W
240V 2.8A 631W
277V 2.4A 630W

HARDWARE AND ACCESSORIES

The iLogic8 can be hung from rope ratchets or can be mounted to a rack.
Before you begin installation, check that you have all the necessary parts to begin.

IN THE BOX

CONNECTION INSTRUCTIONS

  1. Lay the central mast on a flat table top or surface with the attachment brackets facing UP. Attach each LED Bar by aligning the plastic clips and carefully sliding them into place until you hear a soft click.
  2. Once the plastic clips are all snapped in place, attach the A/C cables coming from the mast to each LED bar by aligning the connector pins and pressing the ends together. Lock by twisting in opposite directions.
  3. Once all the LED bars are fastened into place and A/C cables are attached to the mast, turn the fixture over (this may require more than one person). Ensure the flat surface is clear of anything that could damage the delicate diodes.

CAUTION when handling your ILUMINAR Fixture. The LED array should NOT come in contact with sharp objects.
DO NOT touch diodes or apply direct force to the diodes as this can/will cause permanent damage.

HANGING INSTALLATION

  1. To suspend mount, attach the 4 rope ratchets that come packaged with this fixture to the LED.ILUMINAR iLogic8 UV+Far Red 30W 120-277V LED Fixture-7

  2. Lift the LED and attach the carabiners to pre-installed hooks from ceiling or mounting beam. The Ratchets should be installed closest to the LED (and not the ceiling).
    A: Remove slack to raise fixture.
    B: Give slack to lower fixture.

  3. Once fixture is hanging with all LED bars installed, connect the power cable (blue tip) from the outlet to one side of the fixture.

ILUMINAR iLogic8 UV+Far Red 30W 120-277V LED Fixture-8

CABLE LOGIC CONNECTIONS

If you’re planning to utilize several LEDs in your room or facility, one of the many benefits of the ILUMINAR LED is that you can “daisy chain” one fixture to another to save space and use only one outlet to run several lamps thus minimizing the amount of cords used in your space.
If you plan to utilize the ILUMINAR HASH Controller, you can connect the yellow connections from the controller to the fixture and then connect the Daisy Chain Controller Cable from fixture to fixture. Please consult with our lighting layout designers to ensure proper spacing of outlets for your unique setup.

ILUMINAR iLogic8 UV+Far Red 30W 120-277V LED Fixture-9

ILUMINAR iLogic8 UV+Far Red 30W 120-277V LED
Fixture-10

CAUTION

Please read the following list carefully prior to beginning installation.

  1. Leave at least one inch of space between the fixture and the mounting area for maximum performance and lifespan.
  2. ALWAYS wear protective eye wear when looking directly at the diodes to prevent eye damage.
  3. Only handle, clean or move fixture when it’s unplugged and completely cool.
  4. Keep the fixture free of dust, debris, deposits to ensure the maximum potential of the fixture.
  5. NEVER use cloth to clean the diodes. This will scratch the diodes and could potentially break or dislodge them.
  6. DO NOT use chemicals to clean the fixture. Use ONLY low-pressure air or low-pressure water to remove dust and debris.
  7. Do NOT exceed 70% max load for breakers due to Inrush current in LED fixtures.