ILUMINAR IL-HMOL-720 HYPERMOL Full Spectrum 720W User Manual
- October 30, 2023
- ILuminar
Table of Contents
USER MANUAL
HYPERMOL Full Spectrum
720W
IL-HMOL-720
1-877-540-5588
iluminarlighting.com
sales@iluminarlighting.com
Please read this manual thoroughly prior to installing or operating the ILUMINAR HYPERMOL
-
Observe all safety precautions (see page 10), seek the services of a qualified electrician, installation professional, or call ILUMINAR Lighting technicians for assistance.
-
DO NOT handle or touch the fixture while in use.
-
Connect the fixture only to the power sources of the appropriate voltage using the correct AC plug type. Protect power cables from being pinched, walked on, or otherwise damaged. Be especially careful where the power cable enters the power outlet to the unit. Only connect the fixture to an electrical outlet or extension cord of comparable standard and level rating. Connect the fixture ONLY to the power sources of the correct voltage using the plug received.
-
The fixture should only be cleaned as directed. Always seek service for your system by qualified service personnel if any of the following occur:
1. The fixture shows a noticeable change in performance.
2. The power supply cord or plug is damaged.
3. The fixture has been dropped, or the exterior is damaged. -
-
LED Lighting Solution
WATTS: 720W
VOLTAGE: 100-277V
SKU: IL-HMOL-720
TECHNICAL SPECS
Rated Voltage | 120-277V AC |
---|---|
PPF | 1944 µmol/s |
Efficacy | 2.7 µmol/J |
Min Power Factor | >90% |
THD | < 20% |
BTU | 2,462 |
Dimmable | 0-10V Controllable |
Ambient Temperature | 0 – 35°C / 32 – 95°F |
Minimum Mounting Height | 6” to top of Canopy |
Emitter Cooling | Passive / Extruded Case |
Light Distribution | 120º |
LED Lifespan (90% of Life) | 50,000+ hours |
720W LED SPECTRUM
MOUNTING & COVERAGE
58mm / 2.3”
PHYSICAL SPECIFICATIONS
Length | 1065 mm | 41.9” |
---|---|---|
Width | 1005 mm | 43.5” |
Height | 58 mm | 2.3” |
Weight | 22.8kg | 50.3lbs |
VOLTAGE AND AMPERAGE
120V | 6.00A |
---|---|
208V | 3.46A |
220V | 3.27A |
240V | 3.00A |
277V | 2.60A |
HARDWARE AND ACCESSORIES
The HYPERMOL can be hung from rope ratchets or can be mounted to a rack.
Before you begin installation, check that you have all the necessary parts to begin.
IN THE BOX
1 HYPERMOL Fixture
1 Cable
4 Rope Ratchets
BEFORE YOU BUY AN LED
CHECK YOUR REBATE
FIND OUT MORE
HANGING INSTALLATION
[ 1 ] To suspend mount, attach the 4 rope ratchets that come packaged with this fixture to the LED.
A B
[ 2 ] Lift the LED and attach the carabiners to pre-installed hooks from
ceiling or mounting beam. The Ratchets should be installed closest to the LED
(and not the ceiling).
A: Remove slack to raise fixture.
B: Give slack to lower fixture.
[ 3 ] Once fixture is hanging with all LED bars installed, connect the power cable (blue tip) from the outlet to one side of the fixture.
- Controller Cable
- AC INPUT
- Power Supply
CAUTION when handling your ILUMINAR Fixture. The LED array should NOT come in contact with sharp objects. DO NOT touch diodes or apply direct force to the diodes as this can/will cause permanent damage.
CABLE LOGIC CONNECTIONS
With our ILUMINAR Lighting Professional Systems, our new LED lighting fixtures allow growers to connect multiple fixtures using a single power cable.
This cabling solution forms a fixture-to-fixture connection to the power source. Our grow light cables and grow light accessories eliminate the need for the typical mess of LED lighting cables, which have various fixtures with multiple cables running to several power sockets.
Please consult with our lighting layout designers to ensure proper spacing of outlets for your unique setup.
| NAME | VOLTAGE | SKU | LENGTH | DIAGRAM
---|---|---|---|---|---
1| Cable Logic Main-Line AC Extension Cable 0.9m / 3ft 16A
Cable Logic Main-Line AC Extension Cable 1.8m / 6ft 16A
Cable Logic Main-Line AC Extension Cable 4.5m / 15ft 16A | 120V-480V
120V-480V
120V-480V| IL-TML3
IL-TML6
IL-TML15| 0.9m / 3ft
1.8m / 6ft
4.5m / 15ft|
2| Cable Logic Single Joint / Junction Main-Line AC Connector
Cable Logic Multi Joint / Junction Main-Line AC Connector| 120V-480V
120V-480V| IL-SJC
IL-MJC| 1.5m / 5ft
4.5m / 15ft| x2
x4
3| Cable Logic Secondary AC Extension Cables 0.9m / 3ft 10A
Cable Logic Secondary AC Extension Cables 1.8m / Oft 10A | 120V-480V
120V-480V | IL-TS3
IL-TS6 | 0.9m / 3ft
1.8m / 6ft |
5-15P
4| Cable Logic 120V AC Power
Cable Logic 240V AC Power
Cable Logic 277V AC Power
Cable Logic 347V AC Power
Cable Logic Panel Mount 20A – 480 VAC| 120V
240V
277V
347V
480V| IL-T120
IL-T240
IL-T277
IL-T347
IL-PNLM| 0.25m/10″
0.25m/10″
0.25m/10″
0.25m/10″
0.15m / 6″| 6-15P
L7-15P
L24-20P
5| Cable Logic Dimming Cable 0.3m / 1.3ft
Cable Logic Dimming Cable 0.9m / 3ft
Cable Logic Dimming Cable 1.8m / 6ft
Cable Logic Dimming Cable 3m / 10ft
Cable Logic Dimming Cable 6m / 20ft| 0-10V
0-10V
0-10V
0-10V
0-10V| IL-D1
IL-D3
IL-D6
IL-D10
IL-D20| 0.3m / 1.3ft
0.9m / 3ft
1.8m / 6ft
3m / 10ft
6m / 20ft |
Cable Logic Main-Line AC Extension Cable
Available Options
0.9m/3 ft
1.8 m/ 6 ft
4.5m/ 15 ft
Cable Logic Single Joint
1.5 m/5 ft
Cable Logic Secondary AC Extension Cables
Available Options
0.9m/3 ft
1.8 m / 6 ft
Cable Logic 11OV-480V Panel Mount
0.15m/0.5ft
Plug Options:
Cable Logic 120V AC Power
Cable Logic 240V AC Power
Cable Logic 277V AC Power
0.25m / 0.85 ft
Cable Logic Dimming Cable
Available Options
0.3 m / 1.3 ft
1.8 m/ 6 ft
3 m/ 10ft
6 m/ 20ft
A Junction Box
B Electrician Wire to Panel
C Main or Sub Panel
D Hash Controller
E Touch+ Controller
F RJ9 to RJ14 (Included with Touch+ Controller) ****
3m / 10 ft
CAUTION
Please read the following list carefully prior to beginning installation.
- Leave at least one inch of space between the fixture and the mounting area for maximum performance and lifespan.
- ALWAYS wear protective eye wear when looking directly at the diodes to prevent eye damage.
- Only handle, clean or move fixture when it’s unplugged and completely cool.
- Keep the fixture free of dust, debris, deposits to ensure the maximum potential of the fixture.
- NEVER use cloth to clean the diodes. This will scratch the diodes and could potentially break or dislodge them.
- DO NOT use chemicals to clean the fixture. Use ONLY low pressure air or low pressure water to remove dust and debris.
- Do NOT exceed 70% max load for breakers due to Inrush current in LED fixtures.
- Do NOT use sulfur vaporizers.
5 YEAR WARRANTY
GUARANTEE
At ILUMINAR, we stand behind our products and our technology as well as our
customers. All ILUMINAR LED fixtures are backed by our 5-Year Guarantee.
Please visit our website iluminarlighting.
com/warranty for more information.
© Copyright 2023, ILUMINAR Lighting Subject to change without notice.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>