LUMASCAPE LS1012 Centria C3 Foundation User Manual

June 3, 2024
LUMASCAPE

LUMASCAPE - logo LS1012 Centria C3 Foundation
User Manual

LS1012 Centria C3 Foundation

MODEL LS1012
PART NUMBER LS1012 – 24D xxx xx 01 xx xx
INSTALLATION TYPE WALL MOUNT
IP RATING IP66/67 (Passes IP68 Test)
SUPPLY VOLTAGE 220-240 ~Vac, 50 Hz
INSTRUCTIONS COVER Single Color (Non-Dimmable)

Single Color Dimming (Dali)
DIMENSIONS (LxWxH)| 10.0” x 4.7” x 7.0” (255 x 120 x 178 mm)
WEIGHT| 4.5 lbs (2.0 kg)
MAX. PROJECTED AREA| 1.1 ft² (0.1 m²)

Tools Required

LUMASCAPE LS1012 Centria C3 Foundation - Figure 1

Included Components

LUMASCAPE LS1012 Centria C3 Foundation - Figure 2LUMASCAPE LS1012 Centria C3 Foundation - icon
1

Assembly Instructions

LUMASCAPE LS1012 Centria C3 Foundation - Figure 3

Wiring Designations

Non-Dimming (3-Core)

Designation Color
Active Brown
Neutral Blue
Earth Green / Yellow

Dimensions

LUMASCAPE LS1012 Centria C3 Foundation - Figure 4

Please read and follow all safety instructions carefully. Failure to do so will void warranty.

WARNING – Product Warranty is void if product is not installed as per installation instructions and in compliance with all local and provincial codes.

  • Ensure installation complies with local electrical rules and regulations.
  • All electrical work must be performed by a licensed electrician.
  • Protective earth; protective ground (symbol 7).
  • All luminaires may become hot. Use discretion on where the luminaire is mounted. Take care when setting luminaire as it may become hot.
  • Luminaire should only be used complete with protective shield. If protective shield is cracked, immediately stop using luminaire. Isolate light source, keep it dry and  immediately contact Lumascape for replacement of protective shield (symbol 11).
  • If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by Lumascape or their service agent in order to avoid a hazard.
  • If the luminaire is mounted at heights of 9.8′ (3 m) or greater it shall be fitted with additional restraints i.e., lanyards.
  • The light source contained in this luminaire shall only be replaced by Lumascape or their service agent.
  • Do not stare at the operating light source. The luminaire should be positioned so that prolonged staring into the luminaire at a distance closer than 26’ (8 m) is not  expected (symbol 13)
  • Basic insulation has been maintained between line voltage and the control conductors.
  • To reduce the risk of strangulation the flexible wiring connected to this luminaire shall be effectively fixed to the wall if the wiring is within arm’s reach.
  • Ensure mains input power is surge protected.
  • Never make or break connections while the circuit is energized.
  • Do not make modifications or alter the product.
  • Keep luminaire clean and free of debris.
  • Only clean with warm water.
  • Do not use chemicals or abrasives to clean luminaire as this may void the product warranty.
  • Connections are to be kept clean and dry at all times.
  • Suitable for use indoors or outdoors.
  • For mounting on vertical or near vertical surfaces.