HITRON SSR-3 Combined Technology Sensor for Automatic Sliding Doors Installation Guide
- June 1, 2024
- Hitron
Table of Contents
HITRON SSR-3 Combined Technology Sensor for Automatic Sliding Doors
Installation Guide
MOUNT THE SENSOR
Using the mounting template supplied mount the sensor within 50mm of the bottom of the door controller cover
SET MAIN DIPSWITCHES AS ILLUSTRATED
CONNECT TO THE DOOR CONTROLLER
Note: For EN16005 door controllers set Y6 to “ON” and connect the Gray & Brown wires to the door controller. If the door controller does not have a “TEST INPUT” set Y6 to “OFF” and do not connect the Gray & Brown wires
LED INDICATORS
Green Standby
Flashing Green Doorway Learning (When dip switch Y 5
is ON) Flashing Green (once) When responding to the TEST signal
Blue RADAR Detecting
Red ROW 3 Detecting
Slow flashing Red ROW 2 Detecting
Fast flashing Red ROW 1 Detecting
Orange Detection row “ROW1”(“ROW2” when
doorway Learning is turned ON) is detecting door movement
Fast flashing Orange Indicates a change of dip switch settings
Slow flashing Orange Door Hold is turned ON (When dip switch Y 4
is ON) Fast flashing Green/Red Internal Sensor Error
Slow flashing Green/Red Reflected infrared signal from the floor is
very low
SET SAFETY DETECTION AREA
Note: Adjust the depth adjustment lever arm so that the detection area is directly in front of the moving door leaf
SET DESIRED DOOR OPENING DETECTION AREA
]
DOOR LEARN
Turning Door Learn ON (Y5), allows the 1st row of detection to be focused
inside the door close area without detecting door movement.
When Door Learn is turned on, the red LED will blink once, followed by a green
blinking LED, which will turn solid green once the door learn process has been
completed
OTHER USEFUL DIPSWITCH SETTINGS