ThermoWorks Classic Thermapen Instruction Manual
- June 7, 2024
- ThermoWorks
Table of Contents
Classic Thermapen®
Operating Instructions
Congratulations
Classic Thermapen is a precision thermometer used for many applications
including cooking. With proper care it will offer accurate measurements for
many years. Classic Thermapen is splash-proof but should not be immersed.
Instrument Operation
The instrument is switched on by unfolding the thermo-couple probe until the
display comes on. Conversely, the instrument is turned off by folding the
probe away and lightly pressing the tip into the rubber probe retainer located
at the bottom rear of the instrument. It is recommended to store the probe
when not in use.
Rotating hub
Do not force the probe further than 180° or damage to the rotating hub may occur.
The micro-thermocouple sensor is located at the tip of the probe shaft. Minimum immersion is only 1/8″ (3 mm). For best results immerse or penetrate the probe into the food item so the probe tip is in the place you want to measure. In food, this should normally be the thickest part.
Minimum immersion 1/8″ Sensor location
Probe Tip
Classic Thermapen will read to within 1°F of the final temperature of an ice bath within three seconds. Reading times in other foods may vary slightly.
Do not immerse the probe all the way to the plastic rotating hub. Avoid getting flour, moisture, or oil on the hub itself. Although there is an O-ring seal, oils will work their way past the seal and accumulate inside the hub and may cause failure. The probe tip is sharp. Use caution to avoid injury. Do not “stab” the material to be measured. Use steady force to penetrate meats or semi-solids. Avoid bone. Do not lift or flip heavy meats with the probe tip. The probe shaft is hollow and contains a sensor. If bent, it may fail.
Instrument Configuration
You can personalize your Classic Thermapen by changing several factory default
settings including the temperature display units from °F to °C, changing the
temperature display resolution from 1° to 0.1°, and disabling the auto-off
feature. To reconfigure these settings, open the battery compartment (see
Replacing the Batteries section for instructions on opening the battery
compartment) and, using a bent paper clip, change the switch bank settings as
instructed below.
ON 1234, +, CR2032 3V, Switch bank Trim adjust CR2032 battery, Switch (factory default shown)
Switch 1 Units
Changes the instrument’s display units between (°F) Fahrenheit and (°C)
Celsius. The factory default is °F or switch set farthest from batteries. To
change to °C, move the switch to the position closest to the batteries.
Switch 2 Resolution
Changes the instrument’s display resolution between 1°(F or C) and 0.1°(F or
C). The factory default is 1° resolution or switch set farthest from the
batteries. To change to 0.1° resolution, move the switch to the position
closest to the batteries.
Switch 3 Auto-Off
Enables or disables the auto-off function. If the auto-off function is enabled
(factory default), the unit will automatically turn off after 10 minutes to
preserve battery life. If disabled, the unit will remain on until the probe is
folded away and turned off by the user. The factory default is auto-off
enabled or switch set closest to the batteries. To disable the auto-off
function move the switch to the position farthest from the batteries.
Switch 4 Trim Adjust
If the Thermapen is within specification, we do not recommend using the Trim
Adjust. It should not be needed in normal use. This mode allows the user to
set an offset that will add or subtract up to 3.6°F (2.0°C) to all readings of
the Thermapen. It can therefore be used to tune the calibration. For detailed
instructions visit www. thermoworks.com.
Instructions to use the Trim Adjust to tune your Thermapen calibration are downloadable from the Classic Thermapen webpage. You should not need to do this under normal use. A complete factory re-calibration, including a certificate, is also available from ThermoWorks for a fee.
Batteries
Each unit includes two pre-installed CR2032 (3V) coin cell batteries located
inside the sealed battery compartment. An illuminated battery symbol indicates
that the battery should be replaced soon. The instrument will continue to
measure accurately, but it is recommended to replace the batteries
immediately. Once the battery is too low to display readings, the display will
be replaced with Flat’ then
Bat’ and then shut down. To continue using the
instrument, replace the batteries.
Replacing the Batteries
The batteries are pre-installed on your new Thermapen and should last up to
1,500 hours. Should you need to replace the batteries, remove the battery
cover with a coin (a U.S. quarter works best). The battery cover may be tight
in order to maintain the Thermapen’s splash resistance. Using firm but even
downward pressure, rotate the battery cover only to the open position. Lift
the cover from the hole with a fingernail. Place both batteries with the
positive side up making sure that the clip snaps over the batteries to hold
them in place. Replace the battery cover.
CR2032 (x2) Open Rotate to open Lift cover off Do not force past here
Battery Cover
Cleaning and Maintenance 1234 + Battery clip CR2032 3V
To avoid potential bacteria growth and cross-contamination, wipe the probe after each use and regularly clean the entire Thermapen body. Oils and grease should be wiped off the body and the rotating hub. We recommend sanitizing wipes or a damp paper towel with an anti-microbial cleaning solution. DO NOT IMMERSE THE THERMAPEN. The built-in seals will protect the Thermapen from incidental moisture but due to the folding probe, the Thermapen should not be submerged. Protect the plastic body from high temperatures. DO NOT LEAVE THE THERMAPEN IN AN OVEN OR ON A HOT SURFACE.
Warning
IPA and other solvents may cause damage to the case and screen of this
instrument.
Error Messages
- `Lo’ is displayed if measurements are being made below the instrument range.
- `Hi’ is displayed if measurements are being made above the instrument range.
- `Err’ is displayed if the probe develops a fault. Call for details.
For all other error messages, contact ThermoWorks’ Technical Support at 1-800-393-6434 or techsupport@thermoworks.com.
What is NSF Certification?
The NSF Mark indicates that the design, materials, production process and
quality controls used in the production of the Classic Thermapen have been
verified and certified for food safety by NSF International, an independent
standards organization.
Biomaster
Biomaster is a silver-based antimicrobial additive that is molded directly
into the plastic housing that becomes an integral part of the product to
prevent bacteria growth on its surface. The controlled release of the active
ingredient provides maximum antimicrobial protection for the life of the
product. When bacteria come into contact with a Biomaster protected surface,
the silver ions prevent them from growing, producing energy or replicating,
therefore they die, inhibiting degradation, discoloration or odors. Biomaster
is an additional line of defense between cleanings.*
NIST-traceable Calibration Certificate
Your calibration certificate is a document showing that your very own Classic
Thermapen is in compliance with key industrial regulations and that its
performance meets certain key standards for high performance. This means that
your Classic Thermapen was tested in our calibration lab and those
measurements taken are traceable by an unbroken, documented chain of
calibrations to the National Institute of Standards and Technology (NIST).
Repair Services
ThermoWorks offers a full repair service for Thermapens damaged for any
reason. Contact technical support at
1-800-393-6434 or email
techsupport@thermoworks.com.
Additional Technical Information
For more information on using the Thermapen, consult the 20 page Guidebook
included and visit our blog and Help Center for helpful tips and videos at
www.thermoworks.com/blog and
help.thermoworks.com.
Product Warranty
This instrument carries a two-year warranty against defects in either
components or workmanship. During this period, products that prove to be
defective will, at the discretion of ThermoWorks, be either repaired or
replaced without charge. This warranty does not apply to probes, where a six-
month period is offered. Full details of liability are available within
ThermoWorks’ Terms & Conditions of Sale at www.thermoworks.com/product-
warranty.
Thermapen Accessories (available at www.thermoworks.com)
THERMAPEN LEATHER WALLET
Model: 830-110-LX
PROTECTIVE ZIPPER WALLET
Model: 830-001
WALL MOUNT BRACKET
Model: 10203
SILICONE BOOT
Model: 830-260
MAGNETIC GLOW-IN-THE-DARK SILICONE BOOT
Model: 830-265
Made in the UK
Utah, U.S.A.
Phone: 801-756-7705
Fax: 801-756-8948
www.thermoworks.com
Copyright by ThermoWorks, Inc. Content may not be used in whole or in part, without written consent.
ThermoWorks, the ThermoWorks logo and Super-Fast are registered trademarks of ThermoWorks, Inc. Thermapen is a registered trademark of ETI, Ltd. ThermoWorks is the exclusive distribution partner of ETI, Ltd. in North America. All Rights Reserved.
547-100 / 07.01.21 P-11-034-02-n