ThermoWorks THS-179-607 Thermapen Blue Instruction Manual
- June 6, 2024
- ThermoWorks
Table of Contents
Themapen® Blu
Operating Instructions
INSTRUMENT OPERATION – The instrument is switched on by unfolding the
probe and turned off by folding the probe until fully located into the rubber
probe retainer. The probe should not be rotated more than 180 degrees as
damage will occur. It is recommended to store the probe in a closed position
when not in use. When opening the probe, Thermapen Blue will then perform a
battery check and flash twice signifying battery level.
Amber – battery ok
Red – battery low
No lights – battery flat
The battery status can also be viewed using HACCP LE on a smart device.
Apply the tip of the probe to the substance, medium, or surface to be measured. The sensor is located at the tip of the probe, therefore; the minimum depth insertion should be 0.12″ (3mm).
**** The probe tip is very sharp and caution should be taken when using it. Care should also be taken when closing the probe after taking hot temperatures, as the probe may remain hot.
CONNECTION – Use a Bluetooth® enabled iOS or Android™ phone or tablet with HACCP LE installed to connect to the instrument. HACCP LE can be downloaded free from the Apple App Store or on Google Play™. Open HACCP LE and connect to the instrument via the Devices screen, use the instrument’s serial number to select the correct device from the list. When connecting/disconnecting, the instrument’s amber light flashes rapidly 5 times. Once connected, HACCP LE will begin receiving and displaying measurement data.
TRANSMIT BUTTON
MEASURE/TRANSMIT – Press to measure and transmit results via Bluetooth
wireless technology
(Pressing when connected flashes an amber light).
STATUS/TRANSMIT LED – When connected to a phone/tablet an amber LED
flashes every 10 seconds or when the button is pressed.
FAULTY PROBE – If the probe has developed an ‘open circuit fault, HACCP
LE will display ‘Err’.
°C/°F – selectable via the settings screen within HACCP LE.
INSTRUMENT CLEANING – Clean the instrument regularly with an anti-
bacterial probe wipe to
avoid potential food-borne bacteria growth.
WARNING – IPA and other solvents may cause damage to the case of this
instrument.
- Do NOT pry containers, puncture packages, or lift food items with the probe.
- Do NOT expose the thermometer body to temperatures above 122°F (50°C).
- Do NOT expose the tip or probe shaft to temperatures above 572°F (300°C).
- Do NOT stab, jab, or force probe tip into any solid medium. Do NOT force probe tip into frozen food.
- Do NOT allow oils or food to collect on the thermometer body. Clean frequently with sanitizing wipe
- If the amber light starts flashing rapidly during startup, Thermapen Blue us updating firmware. Please leave the probe open and wait for the rapidly flashing lights to stop before use.
BATTERY REPLACEMENT – To replace the battery (1 x AAA), remove the
battery cover with a Phillips screwdriver. Remove the battery by gently
pulling the battery retaining clip back (do not over-extend). Replace the
battery, positive end first, before screwing the battery cover back down. The
battery cover can only be fitted one way.
Please note: Ensure the battery cover is tight against the seal. Do not use
excessive force when refitting the battery cover. For further information on
changing the battery visit www.thermoworks.com/thermapen-
blue.
GUARANTEE – The Thermapen includes a two-year warranty against defects in
either components or workmanship. During this period, products that prove to
be defective will, at the discretion of ThermoWorks, be either repaired or
replaced without charge. This warranty does not apply to probes, where a six-
month period is offered. Full details of liability are available within
ThermoWorks’ Terms & Conditions of Sale at www.thermoworks.com/product-
warranty.
The Bluetooth® word mark and logos are registered trademarks owned by
Bluetooth SIG, Inc. and any use of such marks by ThermoWorks is under license.
Google Play and the Google Play logo are trademarks of Google Inc. Android is
a trademark of Google Inc. Apple, the Apple logo, iPhone, and iPod touch are
trademarks of Apple Inc., registered in the U.S. and other countries. App
Store is a service mark of Apple Inc., registered in the U.S. and other
countries. iOS is a trademark or registered trademark of Cisco in the U.S. and
other countries and is used under license.
SPECIFICATIONS
Range | –58 to 572°F (–49.9 to 299.9°C) |
---|---|
Accuracy | ±0.7°F (±0.4°C) from –58 to 392°F (–49.9 to 199.9°C) otherwise |
±1.8°F (±1.0°C)
Response| 2-3 sec. (reads to within 1°F of the final temperature of an ice
bath in 3 sec.)
Resolution| 0.1° via the remote device
Battery| 1 x AAA / 1000 hours
Sensor| High-performance Type K thermocouple
Connection| Requires Bluetooth 4.1 or above
Probe| 0.125 dia. x 4.3 L inches ( 3.3 dia. x 109 L mm) with a reduced tip to
0.06 dia. inches (1.5 dia. mm)
Water Resistance| IP67
Operating Range| –4 to 122°F (–20 to 50°C)
Dimensions| 1.97 H x 6.2 W x 0.75 D inches (50 H x 157 W x 19 D mm)
Weight| 0.26 lbs (120g)
Calibration| NIST-traceable certificate included
RADIO CERTIFICATIONS
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy, and if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device complies with Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not
cause interference, and (2) this device must accept any interference,
including interference that may cause undesired operation of the device.
ThermoWorks
741 E. Utah Valley Dr., American Fork, UT 84003
Ph: 801-756-7705 Fax:
801-756-8948
thermoworks.com
Made in the UK
Documents / Resources
|
ThermoWorks THS-179-607 Thermapen
Blue
[pdf] Instruction Manual
THS-179-607, Thermapen Blue
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>