Ford Generator Instruction Manual
- June 7, 2024
- Ford
Table of Contents
Generator
Generator
OPERATOR’S MANUAL
MODEL#: FG11050PBE
ITEM#: F2E900E891
Warning: The Engine Exhaust from this product contains chemicals known to the
State of California to cause cancer, birth defects or other reproductive harm.
www.fordpower.cc
TABLE OF CONTENTS
Introduction. ……………………………………………………………………………………………………………………………………………………….3
Product Specifications. ………………………………………………………………………………………………………………………………3
Parts Ordering / Customer Service.
……………………………………………………………………………………………………………..3
Safety Rules. ………………………………………………………………………………………………………………………………………………………4
Safety Symbols. ………………………………………………………………………………………………………………………………………..4 Safety
Instructions ……………………………………………………………………………………………………………………………………4
Features………………………………………………………………………………………………………………………………………………………………7 Assembly
…………………………………………………………………………………………………………………………………………………………..9
Unpacking……………………………………………………………………………………………………………………………………………….. 9 Packing
List . …………………………………………………………………………………………………………………………………………… 9 Remove Shipping
Bracket …………………………………………………………………………………………………………………………10 Attaching Wheels
…………………………………………………………………………………………………………………………………..1. 0 Installing support leg
………………………………………………………………………………………………………………………………..1. 0 Attaching battery cable
…………………………………………………………………………………………………………………………….11 Installing the handles
………………………………………………………………………………………………………………………………..1. 1 Adding Oil/Checking
engine oil …………………………………………………………………………………………………………………..12 Adding Fuel.
……………………………………………………………………………………………………………………………………………13 Connecting Generator
to an Electrical System. …………………………………………………………………………………………..13
Operation …………………………………………………………………………………………………………………………………………………………14
Grounding the Generator ……………………………………………………………………………………………………………………………14 How
to Start Engine. ………………………………………………………………………………………………………………………………..14 How to
Stop Engine. ………………………………………………………………………………………………………………………………..15 Receptacles
and Extension Cords………………………………………………………………………………………………………………15 Don’t Overload
Generator………………………………………………………………………………………………………………………….16 Wattage Reference
Guide. ………………………………………………………………………………………………………………………..17 Cold Weather
Operation. ………………………………………………………………………………………………………………………….18 Maintenance .
…………………………………………………………………………………………………………………………………………………….1. 9 Maintenance
Schedule . ……………………………………………………………………………………………………………………………19 Changing Oil .
…………………………………………………………………………………………………………………………………………20 Engine Maintenance
………………………………………………………………………………………………………………………………..21 Maintaining Fuel Valve.
…………………………………………………………………………………………………………………………….22
How to Store . ………………………………………………………………………………………………………………………………………..23
Troubleshooting . ………………………………………………………………………………………………………………………………………………24
Diagrams……………………………………………………………………………………………………………………………………………………………25
Warranty ……………………………………………………………………………………………………………………………………………………………26
INTRODUCTION
Thank you for purchasing this superior quality portable generator from Ford Power Equipment. When operating and maintaining this product as instructed in this manual, your generator will give you many years of reliable service.
Product Specifications: This generator is an engine-driven, revolving field, alternating current (AC) portable generator. It is designed to supply electrical power to operate tools, appliances, camping equipment, lighting, or serve as a back up power source during power outages.
AC Output
Engine Engine Oil Fuel Tank
GAS
Rated Wattage
9000W (9.0kW)
Rated Voltage
120V/240V
Rated Frequency
60Hz
Rated Ampere
75A / 37.5A
Rated Output
9.0kVA
Maximum Output
11.05kVA
457cc OHV, 4 Stroke, Air Cooled
10W30 – 38oz (1.1L)
6.6 Gal (25L) Unleaded Gasoline
LPG 8100W (8.1kW) 120V/240V 60Hz 67.5A / 33.8A 8.1kVA 10.5kVA
The emissions control system for this generator is compliant with all standards set by the U.S. Agency.
How to contact us: To order parts, receive warranty assistance, or other
services inquiries, you can contact us by internet at www.fordpower.cc
PULSAR PRODUCTS INC 2051 S Lynx Place
Ontario, California, U.S.A 91761
Record the following information bellow for service or warranty assistance.
Date of Purchase: Model Number: Item Number: Serial Number:
SAVE THIS MANUAL FOR FUTURE REFERENCE
This manual contains important information regarding safety, operation, and
maintenance.
3
SAFETY RULES
Safety Symbols WARNING!
CAUTION!
Indicates a potentially hazardous situation which could result in serious
injury or death if not avoided.
Indicates a potentially hazardous situation which could result in damage to
equipment or property.
Toxic Fumes
Risk of fire
Risk of explosion
Risk of electric shock
Hot surface
Lifting hazard
Safety Instructions
The manufacturer cannot anticipate every possible hazardous circumstance that
the user may encounter. Therefore, the warnings in this manual, on tags, and
on affixed decals are not all-inclusive. To avoid accidents, the user must
understand and follow all manual instructions and use common sense.
WARNING!
Read and understand this manual in its entirety before operating this generator. Improper use of this generator could result in serious injury or death.
WARNING!
Do not operate indoors or in a confined space preventing dangerous carbon monoxide gas from dissipating.
· Using a generator indoors WILL KILL YOU IN MINUTES!
· Carbon monoxide gas is a poisonous, odorless gas that can cause headache, confusion, fatigue, nausea, fainting,
sickness, seizures, or death. If you start to experience any of these symptoms, IMMEDIATELY get fresh air and seek
medical attention.
· Never use indoors, in a covered area, or in a confined space, even if doors and windows are open.
· Install a battery operated carbon monoxide alarm near bedrooms.
· Keep exhaust from this unit from entering a confined area through windows, doors, vents, or other openings.
· When working in areas where vapors could be inhaled, use a respirator mask according to all of its instructions.
WARNING! Engine exhaust contains chemicals that lead to cause cancer and birth defects. · Always wash hands after handling generator.
WARNING!
To reduce the risk of serious injury, avoid attempting to lift the generator alone. 4
SAFETY RULES
WARNING! Never exceed generator’s wattage / amperage capacity. This could
damage the generator
and / or connected electrical devices. · Check operating voltage and frequency
requirements of all electrical devices prior to plugging them into the
generator.
WARNING! Never start or stop engine with electrical devices plugged in to the
receptacles. Failure to do
so could damage the generator and / or connected electrical devices. · Always
start the engine and let it stabilize before connecting any electronic
devices. · Disconnect all electronic devices before stopping the engine.
WARNING! Starter and other moving parts can catch on clothing, jewelry, and
hair.
· Do not wear loose clothing or gloves. · Remove jewelry or anything else that
could be caught in moving parts. · Tie back or wear protective head covering
to contain long hair.
WARNING!
Keep engine away from flammable objects and other hazardous materials.
· The fuel and its vapors used to power this unit are highly flammable and
could explode resulting in serious injury or death.
· Never fill or drain fuel tank indoors. · Never overfill fuel tank. If fuel
spills, move the unit at least 30 feet away from the spill and wipe up any
remaining fuel
on the unit before starting the engine. · Never smoke while operating or
fueling this unit. · Never operate or store this unit near an open flame,
heat, or any other ignition source. · Generator should have at least 5 feet of
clearance from buildings or other equipment during operation. · Keep engine
free of grass, leaves, or grease which are flammable. · When adding or
draining fuel, unit should be turned off for at least 2 minutes to cool before
removing fuel cap. If unit
has been running then the fuel cap is under pressure, remove slowly. · To keep
fuel from spilling, secure unit so it cannot tip while operating or
transporting. · When transporting unit, disconnect the spark plug wire and
make sure the fuel tank is empty with the fuel shutoff valve
turned to the off position.
WARNING! Pull cord recoils rapidly and pulls arm towards engine faster than
you can let go which
could result in injury. · To avoid recoil, pull starter cord slowly until
resistance is felt, then pull rapidly.
WARNING!
Avoid contacting hot areas of this unit.
· Use caution around the muffler, cylinder, and other engine parts as they can be extremely hot. · Allow hot components to cool before touching.
5
SAFETY RULES
WARNING!
This generator produces a very high voltage which could result in burns or electrocution causing serious injury or death.
· Never handle the generator, electronic devices, or any cord while standing
in water, while barefoot, or when hands or feet are wet.
· Always keep the generator dry. Never operate generator in rain or under wet
conditions. · Use a ground fault circuit interrupter (GFCI) in a damp or
highly conductive area, such as metal decking or steel
work. · Never plug electronic devices into generator having frayed, worn, or
bare wires. Never touch bare wires or make
contact with receptacles. · Never permit a child or unqualified person to
operate generator. Keep children a minimum of 10 feet away from the
generator at all times. · If using the generator for back up power, notify the
utility company. · If connecting generator to a building’s electrical system
for standby power, you must use a qualified electrician to
install a transfer switch. Failure to isolate the generator from the power utility could result in serious injury or death to
electric utility workers.
WARNING!
Generator must be properly grounded to prevent electrocution.
· Only operate generator on a level surface. · Always connect the nut and ground terminal on the frame to an appropriate ground source.
WARNING! Never modify this unit in any way or modify governed speed.
· Increasing governing speed is dangerous which can result in personal injury
and / or damaged equipment. · Decreasing governing speed adds an excessive
load and can damage equipment. · Only when operating at the preset governing
speed will this generator will supply the correct rated frequency and
voltage.
WARNING! Only use this unit as intended or serious injury or death could
result.
· Do not bypass any safety device. Moving parts are covered with guards. Make
sure all protective covers are in place. · Never transport or make adjustments
to this unit while it is running. · Never insert objects through cooling
slots.
WARNING! Never operate this unit if there are any broken or missing parts and
only use Ford Power
Equipment replacement parts specifically designed for this unit.
· Improper treatment of generator can damage the unit and shorten it’s life. ·
Always repair this unit as specified in this manual. If you have any questions
contact your dealer or consult a qualified
service center. · Shut generator off if electrical output is missing, unit
vibrates excessively or begins to smoke, spark or emit flames.
PROP 65 WARNING: This product contains chemicals known to the state of
California to cause cancer and birth defects or other reproductive harm.
6
FEATURES
A B C D
W
F E G
A – CIRCUIT PROTECTORS B – HOUR METER C – MAIN CIRCUIT BREAKER D – START/ON/OFF SWITCH
E – 120 / 240 VOLT AC, 50 AMP RV OUTLET(NEMA14-50). F – 120 VOLT AC, 30 AMP
TWIST LOCK RECEPTACLE (NEMA L5-30). G – TWO 120 V GFCI DUPLEX RECEPTACLES. W –
FUEL SELECTOR SWITCH
7
FEATURES
H I J
K
L
M N
O
H – FUEL GAUGE I – FUEL TANK VAPOR VENT J – GENERATOR FRAME K – CHOKE LEVER L
– AIR FILTER M – HANDLES & GRIPS N – OIL DRAIN PLUG O – SUPPORT LEG (FOOT)
P Q
R
S T U V
P – FUEL TANK Q – FUEL FILL CAP R – FUEL VALVE (ON/OFF) S – RECOIL STARTER
GRIP T – OIL FILL (DIPSTICK) U – BATTERY V-NO FLAT FOAM FILLED TIRES
8
ASSEMBLY
Unpacking
1. Place box on a level surface. 2. Remove all items from box except the
generator. Make sure all items listed on the packing list are included and not
damaged. 3. Cut down the sides of box being careful to avoid hitting the
generator. 4. Leave generator on box to install wheel assembly.
Packing List
Check all loose parts to the following list. Contact your dealer if any loose
parts are not included.
Description
Qty
Generator
1
Quick Start Guide
1
4-Cycle engine oil (SAE10W-30) 1
Spark Plug Wrench
1
Toolkit Phillips screwdriver
1
Combination Wrench
2
Funnel
1
Handles
2
Bushings (Flanged)
4
One stage regulator
1
Description
Qty
M8 x 45mm Hex Bolts for Handle 2
M8 Flanged Nuts for Handle
2
Wheel
2
Axle
2
Hair pin
2
Hub Cap
2
Screw, Self-Tapping
2
Washer
2
Supporting Leg
1
M8 x 16mm Hex Bolts for Foot 2
M8 Flanged Nuts for Foot
2
++
++
++ +
10W30 OIL
8 – 10
(
) + 10 – 13
9
ASSEMBLY
Remove Shipping Bracket (See fig 1)
· Remove and discard the two RED shipping brackets and mounting hardware
before starting the Generator.
Attaching Wheels (See fig 2)
· Parts needed – 2 wheels, 2 axles, 2 hair pins, 2 washers, 2 hub caps and 2
self-tapping screws. · Raise or tilt generator so you can slide the wheel axle
pin into the wheel, the washer, the wheel mounting hole located
on the side of the frame. · Secure the wheel assembly by reinserting a hair
pin through hole at the end of the wheel axle and pressing until it locks
into place. · Install hub cap to the wheel until “Click”. Install self-tapping
screw, until the screw is snug. · Repeat process on the other side of the
generator to install the second wheel.
Fig 1
Fig 2
Installing Support Leg (See fig 3)
· Parts needed – Support leg & M8 screw (2). · Raise the front end of the
generator high enough to gain access to the bottom of the frame. Securely
position props
underneath to support. · Line up holes on the support leg bracket to the holes
on the front of the generator frame. · Attach the support leg using M8 screws
(2).
Fig 3
Fig 4
10
ASSEMBLY
Attaching Battery Cable (See fig 4)
· Parts needed – Black and Red battery cable · The Red (+) Connector should be
attached to the battery first. · Remove the screw from the battery terminal. ·
Place the screw through the eyelet and tighten the screw and make sure the
terminal will not touch any part of the frame. · Install the Red protection
boot. · Repeat these steps for the Black (-) Terminal.
CAUTION! Be careful not to short across the terminals when installing.
Shorting the terminals together
can cause sparks, damage to the battery or generator, or even burns or
explosions. Cover the terminals with the rubber covers When removing the
battery for replacement: Remove the nut and bolt first from the negative
(Black) post, then from the positive (Red) post, being careful not to short
across the terminals. Always abide by the safety warnings provided with the
battery. Remove the battery and dispose of it according to your local and
state regulations.
WARNING! Battery posts, terminals, and accessories contain lead and lead
compounds known to cause
cancer and reproductive harm. · Always wash hands after touching battery.
Installing The Handles (See fig 5)
Fig 5
Fig 6 11
ASSEMBLY
NON-SPILLABLE
SEALED BATTERY
This is a ready filled, activated sealed battery.
Never remove strip. Refer to owner’s manual or instruction sheet for charging
procedures.
! DANGER/POISON
SHIELD EYES. EXPLOSIVE GASES CAN CAUSE BLINDNESS OR INJURY
NO
SPARKS FLAMES
SULFURIC ACID
CAN CAUSE BLINDNESS OR
SMOKING SEVERE BURNS
FLUSH EYES IMMEDIATLEY WITH WATER
GET MEDICAL HELP FAST
WARNING!
PROPOSITION 65 WARNING
Wear Eye Protection Never Reverse Pole Connections
Battery posts,terminals,and related accessories contain lead and lead compounds,chemicals known to the State of California to cause cancer and reproductive harm.
Never turn the battery upside down
Wash hands after handling.
DO NOT Smoke near the battery
If electrolyte contact the skin wash the area immediately with clean water
If you get electrolyte contact with your eye,rinse immediately with clean water
and seek medical attention
NOTICE:
If the Generator is stored for over six months the battery will need to be removed and charged
Pb
Antidotes for battery acid
CONTACT TREATMENT
External Internal
Flush with water.
Drink large quantities of milk or water, followed by milk of magnesia,
vegetable oil or beaten eggs. Get immediate medical attention.
Eyes
Flush with water. Get immediate medical attention.
Adding / Checking Engine Oil (See fig 7)
· Place generator on a level surface. · Remove the crankcase dipstick to
ensure you do not overfill the engine. · Insert a funnel into the crankcase
dipstick hold and carefully add 4-Cycle engine oil (SAE10W- 30) to empty
reservoir
until oil reaches the outer edge of the oil fill hole (crankcase dipstick
hole). · Be sure to replace dipstick before attempting to start the engine. ·
To check oil, set generator on a level surface, wipe dipstick clean, then
reinsert dipstick without rethreading.
12
ASSEMBLY
Adding Fuel (See fig 8)
· Set generator on a clean and level surface in an area that is well
ventilated. · Remove fuel cap. · Insert a funnel into the fuel tank and
carefully pour gasoline into the tank until fuel level reaches 1 ½ inches
below the
top of the neck. Be careful not to overfill the tank to provide space for fuel
expansion.
CAUTION!
You must add oil before first operating this generator. Always check oil level
before each operation.
DO NOT USE E15 OR E85 FUEL IN THIS UNIT. IT IS A VIOLATION OF FEDERAL LAW AND
WILL DAMAGE THE UNIT AND VOID YOUR WARRANTY.
10W30 OIL
GUansloelaindeed
Fig 7
Fig 8
Connecting Generator to an Electrical System
· If connecting generator to a building’s electrical system for standby power,
you must use a qualified electrician to install a transfer switch. The power
from the generator must be isolated from the circuit breaker or alternative
power source. The connection must comply with all electrical codes and
applicable laws.
WARNING!
This generator produces a very high voltage which could result in burn or electrocution causing serious injury or death.
· Never handle the generator, electronic devices, or any cord while standing
in water, while barefoot, or when hands or feet are wet.
· Always keep the generator dry. Never operate generator in rain or under wet
conditions. · Use a ground fault circuit interrupter (GFCI) in a damp or
highly conductive area, such as metal decking or steel
work. · Never plug electronic devices into generator having frayed, worn, or
bare wires. Never touch bare wires or make
contact with receptacles. · Never permit a child or unqualified person to
operate generator. Keep children a minimum of 10 feet away from the
generator at all times. · If using the generator for back up power, notify the
utility company. · If connecting generator to a building’s electrical system
for standby power, you must use a qualified electrician to
install a transfer switch. Failure to isolate the generator from the power
utility could result in serious injury or death to electric utility workers.
13
OPERATION
Grounding the Generator (See fig 9)
The ground terminal located on the back of the generator frame must always be used
to connect generator to a driven ground rod. Connect the ground terminal to the driven
ground rod with a No 8 AWG (American Wire Gauge) copper wire. The wire connects
to the terminal between the lock washer and nut. Tighten the nut securely to ensure
proper connection. Grounding the generator protects you from electric shock that
results from a build up of static electricity or undetected ground faults.
Fig 9
WARNING!
Generator must be properly grounded to prevent electrocution.
· Only operate generator on a level surface. · Always connect the nut and
ground terminal on the frame to an appropriate ground source.
How to Start Engine (See fig 10-16)
· Place generator on a level surface. All electrical loads MUST be
disconnected from generator. GAS
· Turn fuel valve to the ON position. (See fig 11) · Turn the fuel selector to
“GAS” position (See fig 12) · Slide the choke lever to the “Choke” position.
(See fig 13) SKIP THIS IF THE ENGINE IS WARM OR HOT. · For electric start,
Push and hold the engine START/ON/OFF switch in the “START” position. Do not
hold the START/ ON/OFF switch in the “Start” position for more than 15
seconds. Allow 1 minute between starting attempts. (See fig14) · For manual
start, turn the engine START/ON/OFF switch to the “ON” position. Pull the
recoil handle (starter cord) slowly until resistance is felt, then pull
rapidly. (See fig 15) · Let engine run for several seconds and then gradually,
as engine warms up, slide the choke lever towards the “RUN” position until the
choke is fully slid to the “RUN” position. (See fig 16)
LPG · Turn the fuel selector to “LPG” position (See fig 12) · Connect the
propane hose to the intake nozzle of regulator ; Open the valve of LPG bottle
(See fig 10) · Slide the choke lever to the “Choke” position. (See fig 13)
SKIP THIS IF THE ENGINE IS WARM OR HOT. · For electric start, Push and hold
the engine START/ON/OFF switch in the “START” position. Do not hold the START/
ON/OFF switch in the “Start” position for more than 15 seconds. Allow 1 minute
between starting attempts. (See fig14) · For manual start, turn the engine
START/ON/OFF switch to the “ON” position. Pull the recoil handle (starter
cord) slowly until resistance is felt, then pull rapidly. (See fig 15) · Let
engine run for several seconds and then gradually, as engine warms up, slide
the choke lever towards the “RUN” position until the choke is fully slid to
the “RUN” position. (See fig 16)
CHOKE
RUN
CHOKE LEVER
Fig 10
START
Fig 14 Electric Start
Fig 11
START
Fig 12
CHOKE
WAIT 5sec
RUN
CHOKE LEVER
Fig 15 Recoil Start
14
Fig 16
Fig 13
SKIP THIS IF THE ENGINE IS
WARM OR HOT.
OPERATION
WARNING!
Never start or stop engine with electrical devices plugged in to the receptacles. Failure to do so could damage the generator and / or connected electrical devices.
· Always start the engine and let it stabilize before connecting any electronic devices.
· Disconnect all electronic devices before stopping the engine.
WARNING!
Pull cord recoils rapidly and pulls arm towards engine faster than you can let go which could result in injury.
· To avoid recoil, pull starter cord slowly until resistance is felt, then pull rapidly.
Battery Charger for Electric Starter
Keep the generator battery fully charged and ready to use to avoid the need to
use the recoil starter to start the generator manually.
How to Stop Engine (See fig 17-19)
· All loads MUST be disconnected from the generator. Never start or stop the
engine with electrical devices plugged in to the receptacles.
· Turn the engine START/ON/OFF switch to the “OFF” position. · Turn the fuel
valve to the “OFF” position.
2 START
Fig 17
Fig 18
Fig 19
Receptacles and Extension Cords
Only use high quality, well-insulated, grounded extension cords in good
condition with generator receptacles. Follow each load manufacturer’s power
rating recommendation when selecting receptacle and extension cord.
This generator is equipped with the following receptacles:
· Two 120 V GFCI duplex Receptacles.
· 120 Volt AC, 30 Amp twist lock receptacle (NEMA L5-30). · 120 / 240 Volt AC,
50 Amp RV Outlet(NEMA14-50). 120 Volt AC, 20 Amp receptacle
· This receptacle has a 20 Amp push-to reset circuit breaker to protect
against overload. · Each socket is rated to operate 120 Volt, AC, single
phase, 60Hz loads requiring up to 2400 watts (2.4 kW) at 20 Amps. · Use
extension cords having a minimum rating of 125 Volts AC, 20 Amps.
· L5-30 is rated to operate 120 Volt, AC, single phase, 60Hz loads requiring
up to 3600 watts (3.6 kW) at 30 Amps. 120 /
240 Volt AC, 30 Amp locking receptacle
· This receptacle has a 30 Amp push-to reset circuit breaker to protect
against overload. · This receptacle is rated to operate 120 Volt, AC, single
phase, 60Hz loads requiring up to 3600 watts (3.6 kW) at 30 Amps. It is also
rated to operate 240 Volt AC, single phase, 60Hz loads requiring up to 7,200
watts (7.2 kW). · Use a NEMA L14-30 plug with this receptacle. · Use a 4-wire
cord rated for 240 Volts AC, 30 Amps to the plug. You can use the same 4-wire
cord to operate a 120 Volt load.
15
OPERATION
CAUTION! Do not connect 3-phase loads to generator.
Extension Cord Selection
Refer to the below table to ensure the extension cord used has the capacity to
carry the required load. If the size of the cable is inadequate it can cause a
voltage drop, which can damage the electrical device and cord.
Current (Amps)
2.5 5 7.5 10 15 20 25 30
Load (Watts) 230V 600 1200 1800 2400 3800 4800 6000 7200
Maximum Cord Length
8 Wire
10 Wire
X
1000 ft.
X
500 ft.
X
350 ft.
X
250 ft.
X
150 ft.
175 ft.
125 ft.
150 ft.
100 ft.
125 ft.
65 ft.
12 Wire 600 ft. 300 ft. 200 ft. 150 ft. 100 ft. 75 ft. X X
14 Wire 375 ft. 200 ft. 125 ft. 100 ft. 65 ft. X X X
16 Wire 250 ft. 125 ft. 100 ft. 50 ft. X X X X
Moving the Generator
· Disconnect any electronic devices from generator then turn generator off. ·
Turn fuel valve to the “OFF” position. · Tilt generator until it balances on
wheels. Roll machine to desired location. · If the generator must be carried,
fold handle to the down position. Never lift or carry generator by its handle.
CAUTION!
This product is heavy and requires several people to lift. Lift and lower with your legs by bending at the knees, not your back, to avoid injury.
Don’t Overload Generator
Make sure you can supply enough rated watts and surge watts for all electronic
devices connected to the generator. Rated watts refer to the power a generator
must supply to keep a device running. Surge watts refer to the power a
generator must supply to start an electronic device. This power surge for
starting a device usually lasts between 2-3 seconds but this additional output
must be taken into account when selecting the electronic devices you plan to
attach to the generator. To prevent overloading the generator take the
following steps:
1. Add up the total rated wattage of all electronic devices that will be
connected to the generator simultaneously. 2. Estimate surge watts by adding
the item(s) with the highest output (it is unnecessary to calculate the surge
output for all
devices as they should be connected one at a time). 3. Add the Surge Watts to
the total Rated Watts in step 1. Keep total load within generator’s power
capacity.
Operating voltage and frequency requirement of all electronic equipment should
be checked prior to plugging them into this generator. Damage may result if
the equipment is not designed to operate within a +/- 10% voltage variation,
and +/- 3 Hz frequency variation from the generator name plate ratings. To
reduce the risk of damage, always have an additional load plugged into the
generator if solid state equipment (such as television set) is used. A power
line conditioner is recommended for some solid state applications.
16
OPERATION
Wattage Reference Guide (Wattages listed are just approximations. Check electronic device for actual wattage)
Essentials 75W Light Bulbs 18 CU Ft Refrigerator / Freezer Furnace Fan ( HP) Sump Pump ( HP) Water Pump ( HP) Heating/Cooling Dehumidifier Table Fan Window AC (10k BTU) Central Air (10k BTU) Electric Blanket Space Heater Kitchen Blender Toaster (2 slice) Coffee Maker Electric Range (1 element) Dishwasher Electric Oven Electric Water Heater Laundry Room Iron Washing Machine Gas Clothes Dryer Electric Clothes Dryer
Rated Watts Surge Watts
75 each
75 each
800
2200
800
2350
1000
2000
1000
3000
650
800
800
2000
1200
3600
1500
6000
400
400
1800
1800
300
900
1000
1600
1500
1500
1500
1500
1500
3000
3410
3410
4000
4000
1200
1200
1150
3400
700
2500
5400
6750
Bathroom Hair Dryer Curling Iron Family Room X-Box or Play Station AM/FM Radio VCR Color TV (27″) Home Office Fax Machine Personal Computer (17″ Monitor) Laser Printer Copy Machine Power Tools 1000W Quartz Halogen Work Light Airless Sprayer ( HP) Reciprocating Saw Circular Saw (7 ¼”) Miter Saw (10″) Table/Radial Arm Saw Electric Drill (½ HP, 5.4 Amps) Hammer Drill Air Compressor Other Home Security System Garage Door Opener ( HP)
Rated Watts Surge Watts
1250
0
1500
0
40
0
100
100
100
100
500
500
65
0
800
0
950
0
1600
0
1000
0
600
1200
960
0
1400
2300
1800
1800
2000
2000
600
900
1000
3000
1600
4500
500
500
750
750
WARNING! Never exceed generator’s wattage / amperage capacity. This could
damage the generator
and / or connected electrical devices. · Check operating voltage and frequency
requirements of all electrical devices prior to plugging them into the
generator.
17
OPERATION
Hour Meter (See Fig 20)
The digital hour meter operates whenever the engine is running and keeps track
of how many hours the unit has been used. Use this meter along with the manual
to determine when and what type of service on the unit is needed. The display
will show the word “LUBE” at the first 25 hours of operation and again at
every 100 hours of operation after.
Fig 20
Power Management
· Start engine without anything connected to generator. · When engine has
stabilized, plug in and turn on first load. It is strongly recommended to plug
in devices with the largest
output first and the smallest output last to help prevent overloading the
generator. · Allow generator output to stabilize (engine and attached devices
run evenly) before plugging in the next load.
Cold Weather Operation
Under humid conditions where temperatures drop to 40ºF (4ºC) the carburetor
and/or crankcase breather system may begin to freeze. To prevent icing take
the following steps: 1. Replace any old fuel with clean, fresh fuel. 2. Use
synthetic 5W-30 or SAE 5W-30 engine oil. Check oil daily or after every 8
hours of use. 3. Turn fuel valve to the open position. 4. Ensure generator is
serviced according to the maintenance schedule under “Maintenance” section of
manual. 5. Shelter unit from elements.
High Altitude Operation
At high altitude, the standard carburetor air/fuel mixture will be too rich.
Performance will decrease, and fuel consumption will increase. A very rich
mixture will also foul the spark plug and cause hard starting. Operation at an
altitude that differs from that at which this engine was certified, for
extended periods of time, may increase emissions. High altitude performance
can be improved by specific modifications to the carburetor. If you always
operate your generator at altitudes above 5,000 feet (1,500 meters), have your
dealer perform this carburetor modification. This engine, when operated at
high altitude with the carburetor modifications for high altitude use, will
meet each emission standard throughout its useful life. Even with carburetor
modification, engine horsepower will decrease about 3.5% for each 1,000-foot
(300-meter) increase in altitude. The effect of altitude on horsepower will be
greater than this if no carburetor modification is made.
18
MAINTENANCE
Creating a Temporary Cold Weather Shelter
In an emergency, the original shipping carton can be used as a temporary
shelter. The shelter should hold enough heat created by the generator to
prevent icing. 1. Cut off all flaps. 2. Cut off one of the long sides of the
carton to expose the units muffler and exhaust. Do not enclose the muffler /
exhaust
side of the generator. 3. Slide carton over generator. If necessary, remove
the wheel assembly for fit. 4. Maintain 5 feet of clearance between the open
side of box and other objects. The exposed side of the box should face
away from the wind and elements. 5. Remove shelter when temperatures reach
40ºF (4ºC).
Regular maintenance will extend the life of this generator and improve its
performance. The warranty does not cover items that result from operator
negligence, misuse, or abuse. To receive full value from the warranty,
operator must maintain the generator as instructed in this manual, including
proper storage.
WARNING!
Before inspecting or servicing this machine, make sure the engine is off and no parts are moving. Disconnect the spark plug wire and move it away from the spark plug.
Pre-Operation Steps
Before starting the engine, perform the following pre-operation steps: · Check
the level of the engine oil and the fuel tank level. · Make sure the air
filter is clean. · Remove any debris that has collected on the generator and
around the muffler and controls. Use a vacuum cleaner to
pick up loose debris. If dirt is caked on, use a soft bristle brush. · Inspect
the work area for hazards.
After Each Use
Follow the following procedure after each use: · Shut off engine.) · Store
unit in a clean and dry area.
Maintenance Schedule
After First 5 Hours After 8 Hours or Daily Annually (25 hr Use)
Annually (100 hr Use)
Change Oil Clean Debris Check Engine Oil Level Check and Clean Air Cleaner
Change Engine Oil (Service more often under dirty or dusty conditions) Check
Muffler and Spark Arrester Service Spark Plug (Replace with NGK BP6ES,
Champion N9YC or equivalent) Service Fuel Valve Inspect Muffler and Spark
Arrester Check and Clean Air Cleaner, Replace Air Filter Clean Cooling System
19
MAINTENANCE
Changing Oil (See Fig 21)
· Run the Generator until the Engine is warm. · Place generator on a level
surface. · Remove the crankcase dipstick. · Place an oil pan underneath the
oil drainage bolt to collect used oil. · Remove the oil drainage plug and
allow oil to drain completely. · Reinstall oil drainage plug, tighten
securely. · Carefully add SAE 10W-30 to empty reservoir until the oil reaches
the
outer edge of the oil fill hole (Crankcase Dipstick hole). · Replace crankcase
dipstick.
Oil Fill & Dipstick
Oil drainage plug Fig 21
Oil Recommendations
· Do not use special additives. · Outdoor temperatures determine the proper
oil viscosity for the engine. Use the chart to select the best viscosity for
the
outdoor temperature range expected.
F
C
SAE 30 10W-30 Synthetic 5W-30 5W-30
104
40
86
68
**
30 20
50
10
32
0
14
-10
-4
-20
-22
-30
Note:
**
Below 40 F (4 C) the use of SAE 30 will result in hard starting. Above 80 F(27 C) the use of 10W-30 may cause increased oil Check oil level more frequently.
consumption.
20
MAINTENANCE
CAUTION! Used oil should be disposed of at an approved disposal site. See your
local oil retailer for
more information.
Air Filter (See Fig 22)
A dirty air filter will reduce the life span of the engine, make it difficult
to start the engine, and reduce the unit’s performance. · To clean, remove the
air filter cover. · Carefully pull the air filter out by lifting up along the
edges. · Remove dirt from filter by tapping on it or having it blown out.
Replace with new filter annually. · Reinstall air filter so that it seals and
replace air filter cover.
Checking Spark Plug (See Fig 23)
· Disconnect the spark plug wire from the spark plug. · Before removing the
spark plug, clean the area around its base to prevent debris from entering the
engine. · Clean carbon deposits off the electrode with a wire brush. · Check
the electrode gap and slowly adjust to .700 mm – .80 mm (.028 – .031″) if
necessary. · Reinstall spark plug and tighten to Torque 22.0 26.9 Nm (16-20
ft-lb). · Reconnect spark plug wire. · If spark plug is worn replace only with
an equivalent replacement part. Spark plug should be replaced annually.
(BOSCH F7TC, NGK BP6ES, CHAMPION N9YC or Equivalent)
.700-.800mm
Fig 22
Fig 23
Spark Arrestor (See Fig 24)
· Inspect the spark arrestor for breaks or holes. Replace if necessary. To
purchase a replacement spark arrestor contact PULSAR customer service.
· Use a brush to remove carbon deposits from the spark arrestor screen as
needed. · To remove the spark arrestor: While the muffler is cool, loosen the
locking clamp and slide the spark arrestor out of the
muffler. Reverse this process to install it.
Cooling System
Cooling system should only be serviced by an authorized dealer.
21
MAINTENANCE
Carburetor Adjustment
The carburetor is low emission and is equipped with a non-adjustable idle
mixture valve. If adjustment is needed contact an authorized dealer.
Replacing Fuel Filter (See Fig 25)
Occasionally the fuel filter may become clogged and need replacing. To
purchase a replacement fuel filter contact customer service or your local
small Engine repair shop. · Turn the fuel valve to the “OFF” position. ·
Remove the fuel line from both sides of the filter by squeezing the ends of
the retaining clip with pliers. · Slide the fuel line off. · Replace with new
fuel filter. · Reinstall fuel lines to new fuel filter. · Turn the fuel valve
to the “ON” position.
CAUTION! Fuel tank must be empty before replacing fuel filter. Run unit until
tank is empty, if needed,
or inspect filter prior to fill-up.
Fig 24
Fig 25
Draining Fuel Tank and Carburetor
To help prevent gum deposits in the fuel system, drain the fuel from the tank
and carburetor before storing the unit for long periods of time. This will
help prevent starting problems in the future. If the unit is stored with fuel
and the fuel becomes stale or turns gummy or to varnish the warranty does not
cover this repair or service.
Draining the fuel tank
· Turn the engine OFF. · Turn the fuel valve to the OFF position. · Remove the
fuel line that leads to the carburetor from the petcock by squeezing the ends
of the hose clamps and
sliding the fuel line off. · If needed, install a fuel hose that will extend
to a suitable fuel container large enough to catch the fuel being drained
from the tank. · Turn the fuel valve to the ON position. · When the fuel has
drained from the tank, close the fuel valve and reinstall fuel line securely
on petcock.
22
MAINTENANCE
Draining the carburetor · Turn the engine OFF. · Turn the fuel valve to the
OFF position. · Position a suitable container under the carburetor drain screw
to catch fuel; loosen the screw. · Allow fuel to drain completely into
container. · Retighten drain screw.
CAUTION! Consult your local hazardous waste management in your area for the
proper way to dispose
of used fuel.
Storage and Transportation of the Generator: (See Fig 26)
· Remove any debris that has collected on the generator and around the muffler
and control panel. Use a brush or vacuum to remove loose dirt.
· Inspect air cooling slots. Remove any debris if obstructed. · For short-term
storage, start generator once every 7 days. · For semi-long term storage, add
fuel stabilizer to prevent stale fuel from causing acid and gum deposits in
the fuel system
and carburetor. · For long-term storage, drain the fuel. · Store the generator
indoors to prevent freezing. · The generator must be Shipped, Run and Stored
in the upright position as seen in this image.
Fig 26
Engine Long Term Storage:
· Remove the spark plug and pour about 1 teaspoon of 10W30 Engine oil into the
spark plug hole. Reinstall the spark plug. With the ON/OFF switch in the OFF
position pull the recoil starter cord several time to coat the cylinder walls
with oil.
· Slowly pull the recoil Starter until you feel the engine build compression
(When you feel resistance). Leave the Engine in this state as this will
prevent any corrosion on the cylinder walls if stored for a long period of
time.
23
TROUBLESHOOTING
Problem
Engine is running, but AC output is not available
Cause
1. Open circuit breaker 2. Poor connection 3. Defective cord set 4. Connected
device is faulty 5. Fault in generator
Engine runs well without load but bogs down when loads are connected
1. Short circuit in connected device 2. Generator is overloaded 3. Clogged fuel filter 4. Engine speed is too slow 5. Short circuit in generator
Engine will not start, shuts down during 1. ON/OFF switch set to “OFF”
operation, or starts and runs rough. 2. Dirty Air filter
3. Clogged fuel filter 4. Stale fuel 5. Spark plug wire disconnected from
spark plug 6. Bad spark plug 7. Water in fuel 8. Fuel valve is in “OFF”
position 9. Over choking 10. Low oil level 11. Rich fuel mixture 12. Intake
valve stuck open or closed 13. Loss of engine compression 14. Dead battery 15.
Engine has flooded
Engine lacks power
1. Generator is overloaded 2. Clogged fuel filter 3. Dirty Air filter 4. Engine needs servicing
Solution
1. Reset circuit breaker 2. Check and repair 3. Check and repair 4. Connect a
device that is working
properly 5. Contact service department
1. Disconnect device 2. See pg 15 “Don’t overload
generator” 3. Clean or replace fuel filter 4. Contact service department 5.
Contact service department
1. Turn switch to “ON” 2. Replace Air filter 3. Clean or replace fuel filter
4. Replace fuel 5. Reconnect spark plug wire 6. Replace spark plug 7. Drain
fuel tank and replace fuel 8. Turn fuel valve to “ON” position 9. Turn off
choke 10. Fill crankcase to proper oil level &
place generator on a level surface 11. Contact service department 12. Contact
service department 13. Contact service department 14. Recharge or replace
battery 15. Wait 5 minutes and recrank engine
1. See pg 15 “Don’t overload generator” 2. Clean or replace fuel filter 3.
Replace Air filter 4. Contact service department
Engine “hunts” or falters
1. Choke was removed too soon 2. Clogged fuel filter 3. Carburetor is running
too rich or too
lean
1. Move choke to middle position until engine runs evenly
2. Clean or replace fuel filter 3. Contact service department
24
DIAGRAMS
25
WARRANTY
Ford Power Equipment Limited 2 Year Warranty: From the date of original
purchase, Ford Power Equipment warrants to the original purchaser that each
portable generator sold, shall be free from defect in material and workmanship
for the items and time period set forth below. Ford Power Equipment, at its
discretion, agrees to repair or replace any defective part that upon
examination, inspection, and testing by a Ford Power Equipment authorized
service dealer, is found to be defective within the original warranty period.
Ford Power Equipment will also decide upon the use of new or rebuilt parts or
comparable product. Any part or product that is replaced will be retained by
Ford Power Equipment. This warranty period shall not be extended and any
repaired product shall be warranted for the remaining period of the original
warranty. The consumer is responsible, and shall prepay all transportation
costs, including returning items to the factory or warehouse. This warranty is
non-transferable and proof of purchase must be presented for requesting
warranty service. If a proof-of-purchase receipt is not provided, the
product’s shipping date by the manufacturer will be used to determine the
warranty period.
Length of Warranty: Personal use applications of this portable generator are
warranted for 24 month or 500 hrs using (Whichever comes first). Proof of
purchase and ofmaintenance must be provided. · 6 Month – Limited comprehensive
coverage on all generator components and labor. · 12 Month – Limited coverage
on generator engine and alternator components, parts only. · 24 Month –
Limited coverage on generator engine components, parts only.
“Personal use” means personal residential household use or recreational use by
the retail consumer. “Commercial use” means all other uses including
commercial, construction, or other income producing purposes. Once a generator
has been used for commercial purposes, it shall thereafter be considered as a
“commercial use” generator for the purposes of this warranty. Any portable
generator used for commercial use, as rental equipment or for the purpose of
primary power in place of utility, will not be covered under this warranty.
Consumer Responsibilities: · Consumer is responsible for carefully reading and
following all instructions in the owner’s manual. Any product that is
damaged due to misuse or abuse will not be covered by this warranty. ·
Consumer is responsible for all transportation costs to an authorized Ford
Power Equipment Service Center. Unless
otherwise requested, ground shipping will be applied for part shipment and
customer will pay any additional charges for expedited shipments. · Consumer
is responsible for labor costs associated with warranted repairs twelve (12)
months after the purchase date. Labor rates will only be based on normal
working hours. · Consumer is responsible for maintaining generator as
specified in the owner’s manual. Documentation of this maintenance may be
required to cover warranty requests. · Consumer is responsible for presenting
any problems with the generator to an authorized Ford Power Equipment Service
Center as soon as the problem exists. Warranted repairs will be completed in a
reasonable period of time, not to exceed 30 days.
26
WARRANTY
What this Warranty Does Not Cover: · Normal wear: This warranty excludes
normal wear items such as filters, spark plugs, gaskets, O-rings, adapter cord
sets, wheels, and starting batteries. · Maintenance: This warranty does not
apply to tune-ups or routine maintenance and does not cover any adjustments or
repairs not performed by an authorized repair facility. · Misuse: This
warranty does not apply if your product has failed due to abuse, misuse,
neglect, using incorrect fuels or
lubricants, overloading, overspeeding, improper maintenance, improper storage,
unapproved modifications, or has been operated in any way contrary to the
instructions found in the products owner’s manual. · Adverse conditions: This
warranty does not apply if your product has failed due to freezing, accident
or natural disasters. · Product shipment: This warranty does not apply to
damage resulting from shipping, handling, or warehousing. Any damage claims to
this product caused by shipment must be filed with freighter. · Other
exclusions: This warranty does not apply if your product has been sold “as is”
or where the factory applied serial number has been removed. Refurbished,
used, demonstration or floor models are not covered by this warranty.
Where Warranty is Valid: For warranty coverage, this product must be purchased
from an authorized Ford Power Equipment dealer and the warranty only extends
to the original purchaser. Refurbished, used, demonstration, or floor models
are not covered by this warranty. Products purchased from on-line auction
websites, such as ebay, are not covered under this warranty. Products used for
commercial use are not covered under this warranty.
How to Obtain Warranty Service: Take the original receipt and product to the
place of purchase or mail the original receipt and product to the address
found on the web site if purchased on-line. You can also locate your nearest
Ford Power Equipment dealer for service or warranty questions by calling toll
free at 1-888-863-7589. Ford Power
Equipment recommends you retain all of your receipts covering the purchase and
maintenance of your Portable Generator, but will not deny you warranty
coverage as long as proof of purchase or service can be obtained.
Ford Power Equipment’s obligation under this warranty is exclusively limited
to product repair or replacement and shall not be liable for any incidental or
consequential damages including, but not limited to, the expense of delivering
product to and from a repair center, loss or damage to personal property, loss
of revenue, telephone charges, loss of time, or inconvenience. Some states,
provinces or jurisdictions do not allow the exclusion or limitation of
incidental damages, so the above limitation may not apply to you. The warranty
gives you specific legal rights, and you may also have other rights which vary
from state to state or province to province.
Rev.A 050517
27
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>