- Description: The Cloud 9 User Manual includes a description, of safety precautions, installation, programming, operation and maintenance instructions for the Cloud 9.
- Trademarks: CHAUVET, the Chauvet logo and Cloud 9 are registered trademarks or trademarks of Chauvet & Sons, LLC (d/b/a Chauvet and Chauvet Lighting) in the United States and other countries. Other company and product names and logos referred to herein may be trademarks of their respective companies.
- Copyright Notice: Manual Use. Chauvet authorizes its customers to download and print this manual for professional information purposes only. Chauvet expressly prohibits the usage, copy, storage, distribution, modification, or printing of this manual or its content for any other purpose without written consent from Chauvet.
- Document Printing: For best results, print this document in colour, on letter size paper (8.5 x 11 in), double-sided. If using A4 paper (210 x 297 mm), configure the printer to scale the content accordingly.
- Intended Audience: Any person installing, operating, and/or maintaining this product should completely read through the guide that shipped with the product, as well as this manual, before installing, operating, or maintaining this product.
- Disclaimer
- Document Revision: This Cloud 9 User Manual is the 4th edition of this document. Go to www.chauvetprofessional.com for the latest version.
Before You Begin
Introduction
Description:
The Cloud 9 is a lighting fixture that provides various lighting effects.
Features:
- Feature 1: Provides a wide range of colours and patterns.
- Feature 2: Multiple control options including DMX control.
- Feature 3: Sturdy and durable construction.
Setup
-
AC Power
The Cloud 9 requires AC power to operate. Ensure that the power source meets the specified voltage requirements. -
AC Plug
Connect the AC plug to a suitable power outlet. -
Resetting the Breaker
If the Cloud 9 experiences a power overload or fault, the breaker may trip. To reset the breaker, locate the breaker switch and flip it back to the “On” position. -
DMX Linking
The Cloud 9 can be linked to a DMX controller for more advanced control options. Follow the instructions provided with your DMX controller to properly connect and configure the DMX linking. -
DMX Personalities
The Cloud 9 supports multiple DMX personalities, allowing you to customize the control settings based on your specific needs. Refer to the user manual of your DMX controller to set the appropriate DMX personality for Cloud 9. -
Mounting
Before mounting the Cloud 9, ensure that the mounting surface is sturdy and capable of supporting the weight of the fixture. Use appropriate mounting hardware and follow the instructions provided to securely mount the Cloud 9. -
Operation
-
DMX Control
The Cloud 9 can be controlled using a DMX controller. Connect the DMX controller to the Cloud 9 using a compatible DMX cable and follow the instructions provided with your DMX controller to send control signals to the fixture. -
DMX Values
The Cloud 9 responds to specific DMX values to control various parameters such as colour, intensity, and movement. Refer to the DMX value chart provided in the user manual to understand the corresponding values for different settings. -
Configuration (Standalone)
If you are not using a DMX controller, the Cloud 9 can be configured to operate in standalone mode. Use the onboard controls and menu options to adjust settings such as color, pattern, speed, and intensity.
FAQ
-
Q: Can I use the Cloud 9 without a DMX controller?
A: Yes, the Cloud 9 can be operated in standalone mode without a DMX controller. Simply use the onboard controls to adjust the settings. -
Q: Can I mount the Cloud 9 on any surface?+
A: No, ensure that the mounting surface is sturdy and capable of supporting the weight of the fixture. Follow the instructions provided for proper mounting. -
Q: Where can I find the latest version of the user manual?
A: Visit www.chauvetprofessional.com to find the latest version of the Cloud 9 User Manual.
EDITION NOTES
The Cloud 9 User Manual includes a description, safety precautions,
installation, programming, operation and maintenance instructions for the
Cloud 9.
Trademarks
CHAUVET, the Chauvet logo and Cloud 9 are registered trademarks or trademarks
of Chauvet & Sons, LLC (d/b/a Chauvet and Chauvet Lighting) in the United
States and other countries. Other company and product names and logos referred
to herein may be trademarks of their respective companies.
Copyright Notice
- The works of authorship contained in this manual, including, but not limited to, all design, text and images are owned by Chauvet.
- © Copyright 2018 Chauvet & Sons, LLC. All rights reserved. Electronically published by Chauvet in the United States of America.
Manual Use
Chauvet authorizes its customers to download and print this manual for
professional information purposes only. Chauvet expressly prohibits the usage,
copy, storage, distribution, modification, or printing of this manual or its
content for any other purpose without written consent from Chauvet.
Document Printing
For best results, print this document in colour, on letter size paper (8.5 x
11 in), double-sided. If using A4 paper (210 x 297 mm), configure the printer
to scale the content accordingly.
Intended Audience
Any person installing, operating, and/or maintaining this product should
completely read through the guide that shipped with the product, as well as
this manual, before installing, operating, or maintaining this product.
Disclaimer
Chauvet believes that the information contained in this manual is accurate in
all respects. However, Chauvet assumes no responsibility and specifically
disclaims any liability to any party for any loss, damage or disruption caused
by any errors or omissions in this document, whether such errors or omissions
result from negligence, accident or any other cause. Chauvet reserves the
right to revise the content of this document without any obligation to notify
any person or company of such revision, however, Chauvet has no obligation to
make and does not commit to make any such revisions. Download the latest
version from
www.chauvetprofessional.com.
Document Revision
This Cloud 9 User Manual is the 4th edition of this document. Go to
www.chauvetprofessional.com for the
latest version.
BEFORE YOU BEGIN
What Is Included
- Cloud 9
- Electronic powerCON power cord
- Directional Hose and Clamp
- Quick Reference Guide
Claims
Carefully unpack the product immediately and check the container to make sure
all the parts are in the package and are in good condition. If the box or the
contents (the product and included accessories) appear damaged from shipping,
or show signs of mishandling, notify the carrier immediately, not Chauvet.
Failure to report damage to the carrier immediately may invalidate your claim.
In addition, keep the box and contents for inspection. For other issues, such
as missing components or parts, damage not related to shipping, or concealed
damage, file a claim with Chauvet within 7 days of delivery.
Manual Conventions
Convention | Meaning |
---|---|
1–512 | A range of values |
50/60 | A set of values of which only one can be chosen |
< SET> | A button on the product’s control panel |
Settings | A product function or a menu option |
Symbols
- Critical installation, configuration, or operation information. Not following these instructions may make the product not work, cause damage to the product, or cause harm to the operator.
- Important installation or configuration information. The product may not function correctly if this information is not used.
- Useful information.
- Any reference to power connections in this manual assumes the use of Seetronic IP-rated cables.
- The term “DMX” used throughout this manual refers to the USITT DMX512-A digital data transmission protocol.
Safety Notes
Read all the following safety notes before working with this product. These
notes contain important information about the installation, usage, and
maintenance of this product.
- This product contains no user-serviceable parts. Any reference to servicing in this User Manual will only apply to properly trained, certified technicians. Do not open the housing or attempt any repairs.
- All applicable local codes and regulations apply to the proper installation of this product.
Personal Safety
- Depending on the amount of fog generated, all fog machines may set off smoke detectors.
- Drain the tank before transporting the product.
- Always disconnect this product from its power source before servicing.
- The product’s nozzle is very hot during operation and it remains hot for a long time after operation has stopped.
- Always connect this product to a grounded circuit to avoid the risk of electrocution.
- Do not swallow fluid. MSDS for Chauvet fluids are available for download from our website.
- People with asthma or respiratory issues should avoid prolonged exposure.
- Do not use for space heating purposes.
- Do not touch this product’s housing during operation because it may be very hot.
Mounting and Rigging
- This product is for indoor use only! To prevent the risk of fire or shock, do not expose this product to rain or moisture. (IP20)
- CAUTION: When transferring product from extreme temperature environments, (e.g. cold truck to a warm humid ballroom) condensation may form on the internal electronics of the product. To avoid causing a failure, allow the product to fully acclimate to the surrounding environment before connecting it to power.
- Mount this product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.
- Make sure there are no flammable materials close to this product while it is operating.
Power and Wiring
- Always make sure you are connecting this product to the proper voltage by the specifications in this manual or on the product’s specification label.
- To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the product from power via a breaker or by unplugging it.
- Never connect this product to a dimmer pack or rheostat.
- Never disconnect this product by pulling or tugging on the power cable.
- The 120V version of the Cloud 9 consumes more than 20A of power and thus requires 2 power cords, with each on its own circuit.
Operation
- Do not operate this product if you see damage to the housing, fluid tank, or cables. Have the damaged parts replaced by an authorized technician at once.
- Be sure that no ventilation slots on the product’s housing are blocked.
- Never carry the product from the power cord or any moving part. Always use the handles.
- The fog exits the nozzle at a very high temperature and it remains hot for a long time after the operation has stopped. Keep a minimum distance of 6.5 ft (2 m) from the nozzle to the nearest object.
- The maximum ambient temperature is 113 °F (45 °C). Do not operate this product at a higher temperature.
- In the event of a serious operating problem, stop using this product immediately!
- Do not add perfume, alcohol, gasoline, or any other flammables to the fog fluid.
- Use only CHAUVET-approved fog or haze fluid (PHF, QDF, or HDF)!
- If your Chauvet product requires service, contact Chauvet Technical Support.
INTRODUCTION
Description
The Cloud 9 is a low-lying fog machine that creates thick clouds that hug the
floor without the need for dry ice. The ultrasonic agitator converts distilled
water into a thin mist. The unit’s fast heat-up time allows for quick
operation and fog on demand. Its flight case makes transportation a breeze and
locking casters prevent accidental rollaways. The Cloud 9 can be controlled
with the onboard digital display or DMX.
Features
- Professional fogger gives high-impact low-lying fog effect on stage or in ballrooms
- The continuous operation produces fog to cover a 3,230 ft2 (300 m2) area
- Ultrasonic agitator combines distilled water with fog to produce a low-lying fog effect
- Ships in rugged flight case with locking casters with hinged top cover to allow for operation even when closed
- Control via onboard digital display or DMX
- An integrated water drain system makes cleanup fast and easy
- Works with fog fluid, haze fluid, or quick-dissipating fluid for the desired effect
- Use without dry ice or CO2, so no special licensing/training required
Product Overview
Product Dimensions
SETUP
AC Power
Each Cloud 9 has a fixed power supply that works with an input voltage of
either 120 VAC, 60 Hz or 230 VAC, 50 Hz, depending on the specific model. To
determine the power requirements for each Cloud 9, refer to the label affixed
to the product. You can also refer to the Technical Specifications chart in
this manual.
The listed current rating indicates the maximum current draw during normal operation. For more information, download Sizing Circuit Breakers from the Chauvet website: www.chauvetprofessional.com.
- Always connect the product to a protected circuit (circuit breaker or fuse). Make sure the product has an appropriate electrical ground to avoid the risk of electrocution or fire.
- To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the product from power via a breaker or by unplugging it.
- Never connect the product to a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel serves only as a 0 to 100% switch.
AC Plug
The Cloud 9 comes with a power input cord terminated with a Seetronic Powerkon
connector on one end and an Edison plug on the other end (U.S. market). If the
power input cord that came with your product has no plug, or if you need the
change the plug, use the table below to wire the new plug.
Connection | Wire (U.S.) | Wire (Europe) | Screw Color |
---|---|---|---|
AC Live | Black | Brown | Yellow or Brass |
AC Neutral | White | Blue | Silver |
AC Ground | Green/Yellow | Green/Yellow | Green |
Resetting the Breaker
This product is equipped with a resettable circuit breaker. If the breaker
trips, all sections of this product will lose power.
- Remove the power cord from mains power.
- Allow unit to cool for 15 minutes.
- After 15 minutes, you may attempt to reset the breaker by pressing the button with your finger.
- Plug the product’s power cord into the power outlet and continue using it as recommended.
DMX Linking
You can link the Cloud 9 to a DMX controller using a 3- or 5-pin DMX
connection. If using other DMX-compatible products with this product, you can
control each individually with a single DMX controller.
DMX Personalities
The Cloud 9 uses a 3- or 5-pin DMX data connection for the 2-channel DMX
personality.
- Refer to the Introduction for a brief description of each DMX personality.
- Refer to the Operation chapter to learn how to configure Cloud 9 to work in these personalities.
- The DMX Values section provides detailed information regarding the DMX personalities.
If you are not familiar with or need more information about DMX standards,
Master/Slave connectivity, or the DMX cables needed to link this product to a
DMX controller, download the DMX Primer from the Chauvet website:
www.chauvetprofessional.com.
-
Mounting
Before mounting the product, read and follow the safety recommendations indicated in the Safety Notes. -
Orientation
Always mount this product in a safe position, making sure there is adequate room for ventilation, configuration, and maintenance. -
Rigging
Chauvet recommends using the following general guidelines when mounting this product.- Before deciding on a location for the product, make sure there is easy access to the product for maintenance and programming purposes.
- Make sure that the structure onto which you are locating the product on can support the product’s weight. See the Technical Specifications for weight information.
-
Procedure
The Cloud 9 includes 4 rubber wheels that are attached for floor mounting. -
Mounting Diagram
Hose Attachment
The Cloud 9 comes with a directional hose and a clamp that attaches to the
nozzle for a low-lying fog effect. To attach or remove the hose, use the hose
clamp to secure the directional hose to the nozzle.
- This product may NOT be tilted. This product should be level while operating. Drain all distilled water before transporting or storing.
- When securing the directional hose, ensure that the bolt of the hose clamp is placed in one of the four corners of the nozzle frame.
OPERATION
Control Panel Operation
Button/Knob | Function |
---|---|
< MENU> | Exits from the current menu or function |
< UP/TIMER> | UP navigates upwards through the menu list and |
increases the numeric value when in a function.
TIMER starts the timer-controlled operation
< DOWN/VOLUME>| DOWN navigates downwards through the menu list and decreases the numeric
value when in a function.
VOLUME triggers the pump to modify the output volume
< ENTER/STOP>| ENTER enables the currently displayed menu or sets the currently selected value into the selected function.
STOP turns the fog output off.
- If the product is turned off while in timer mode, the product will still be when the product is turned back on.
- The Cloud 9 can operate with the top lid on or off.
Control Options
Set the Cloud 9 starting address in the 001-512 DMX range. This enables
control of up to 257 products in the 2-channel personality.
Programming
Refer to the Menu Map to understand the menu options. The menu map shows the
main level and a variable number of programming levels for each option.
- To go to the desired main level, press
repeatedly until the option shows on the display. This will take you to the first programming level for that option. - To select an option or value within the current programming level, press
or until the option shows on the display. If there is another programming level, you will see that first option, or you will see the selected value. - Press
repeatedly to exit to the previous main level
Preparing for Operation
To prepare the Cloud 9 for operation:
- Place the machine on a level surface. Plug the power cord into the wall.
- Remove the top lid.
- Fill the water tank with distilled water to the maximum fill line located on the inside of the tank. The container can hold up to 5.3 gal or (20 l).
- Fill the fluid tank with CHAUVET haze or fog fluid to the maximum fill line located on the outside of the tank. The container can hold up to 1 gal (3.5 l).
- Turn the product on using the power switch on the back panel. Make sure the fans are operating properly.
- Using the control panel, set the product to the desired operating mode.
Allow the Cloud 9 four minutes to heat up before continuing.
- When storing the product, ALWAYS be sure to store the fluid tank with the cap up as seen on the Product Mounting Diagram above before installing the front cover to avoid tube damage that may cause leakage.
- Condensation may form on the bottom of the product, creating damp conditions under and around the Cloud 9. Use caution! Surfaces around the product may become slippery.
- Filling the distilled water tank above the maximum fill line will reduce the performance of the product. To ensure optimal performance, drain any excess water via the overfill drain prior to use.
- Only use Chauvet-approved haze or fog fluid. Using any other fluid will void your product warranty
Operation Continued
To prepare the Cloud 9 for operation:
- Open the flight case.
- Pull out the fluid tank and remove the cap.
- Verify that the two plastic hoses attached to the inside of the cap are in place and in good condition.
- Pour Chauvet fog fluid inside the tank, and re-cap.
- Reinsert the tank.
- Make sure that the plastic hose that goes from the cap to the fogger is not bent.
- Plug in power and wait approximately 4 minutes for the warm-up to complete.
- Due to water evaporation, you may need to refill the Cloud 9 with distilled water to continue triggering the machine.
- The Cloud 9 is fitted with a safety shutoff feature, which prevents the unit’s heaters from turning on when the water level is too low. If this safety shutoff feature has been engaged, simply add more water to continue using Cloud 9.
- While operating the Cloud 9, make sure there is adequate fog or haze fluid and distilled water in the machine to prevent pump and heater damage. When the fog fluid/distilled water level becomes low, simply add more fog or haze fluid to continue using the Cloud 9.
Menu Map
Mode | Programming Levels | Description |
---|---|---|
Interval Set | 5–200S | Sets the interval between fog output |
Duration Set | 5–200S | Sets the duration of the fog output |
Timer Out | 1- 100% | Sets the output volume in timer mode |
Volume Out | 1–100% | Fog volume 1–100% |
Fan Speed | 1–100% | Fan Speed (slow to fast) |
Fluid Sensor | ON/OFF | Turns the fluid sensor ON or OFF |
DMX512 Address | 1–512 | Select the DMX starting address |
Direct Timer | NO/YES | Enables/disables the timer |
Configuration (DMX)
Use DMX configurations to operate the product with a DMX controller.
DMX Control
In this mode, each product will respond to a unique starting address from the
DMX controller. All products with the same starting address will respond in
unison.
- Go to DMX512 Address. main level.
- Select the starting address (1–512).
DMX Values
2CH
Channel | Function | Value | Percent/Setting |
---|---|---|---|
1 | Fan Speed | 000 ⇔ 010 | No function |
011 ⇔ 512 | 1–100% | ||
2 | Fog Output | 000 ⇔ 010 | No function |
011 ⇔ 512 | 1–100% |
Configuration (Standalone)
Use a standalone configuration to operate the product without a DMX
controller.
Interval
This feature sets the interval between fog output. To control the Interval
between fog output, follow the instructions below.
- Go to Interval Set main level and press Enter.
- Use the UP and DOWN arrows to select the desired speed (5-200S).
Duration
This feature sets the duration of fog output. To control the Duration of fog
output, do the following:
- Go to the Duration Set main level and press Enter.
- Use the UP and DOWN arrows to select the fog duration (5-200S).
Timer Out
This feature sets the output volume in timer mode. To access the Timer Out
mode, follow the instructions below.
- Go to the Timer Out main level and press Enter.
- Use the UP and DOWN arrows to select the output volume, 1-100%.
Volume Out
This feature sets the fan speed. To set the Fan Speed, do the following:
- Go to the Fan Speed main level and press Enter.
- Use the UP and DOWN arrows to select the fan speed, 1-100%.
Fluid Sensor
This feature enabled the fluid sensor to be turned on or off. To access the
Fluid Sensor mode, follow the instructions below.
- Go to the Fluid Sensor main level.
- Use the UP and DOWN arrows to select ON or OFF.
Direct Timer
This feature can enable or disable the timer. To access the Direct Timer, do
the following:
- Go to the Direct Timer main level.
- Use the UP and DOWN arrows to select NO or YES.
TECHNICAL INFORMATION
Product Maintenance
Do not allow the fog machine to become clogged. After every 40 hours of
continuous operation, use the CHAUVET Fog Cleaner Quart (FCQ) through the
system to prevent the accumulation of particulate matter in the heating
element.
The recommended cleaning procedure is as follows.
- Unplug the product from power.
- Empty all fog fluid from the machine.
- Add cleaning solution to the tank.
- Connect the product to power and allow it to warm up.
- Run the unit in a well-ventilated area until the tank is empty.
- Refill with fog fluid to continue using the fogger. Run the machine briefly to clear any cleaning solution from the pump and heater.
- FCQ (Fog Cleaner Quart) was specifically developed by CHAUVET to clean your Cloud 9. Make sure you use FCQ regularly to increase the life of your fogger.
- Do not spin the fans using compressed air because you could damage the fogger.
- Test-run your Cloud 9 every month to achieve the best performance.
- Never operate the machine without fluid.
Storage
Before storing the fogger, run FCQ through the system as described in the
cleaning procedure above; however, only follow steps 1 through 5. Do not
refill the tank with fog or haze fluid if storing the fogger. Cleaning the
system prior to storage will help prevent any particles from condensing inside
the pump or heater while not in use.
Control Panel Information
The Cloud 9 has status messages and warnings that may appear on the control
panel while operating the product. Use the table below to understand the
status messages that may appear on the control panel of Cloud 9.
Status Message/Warning| Status Description| Recommended
Action
---|---|---
Fog Fluid Low| Displays when the Cloud 9 is operating and the fog fluid
is low.| Refill fluid
Failure to Heat| Displays when the Cloud 9 is turned on and the heater
fails to reach operating temperatures| Contact customer service.
Ready to Go Low| Displays when the Cloud 9 is heated and ready to
operate.| Operate the Cloud 9.
Distill H2O Low| Displays when the distilled water tank is low on
fluid.| Refill the distilled water tank.
TECHNICAL SPECIFICATIONS
Dimensions and Weight
RETURNS
- Send the product prepaid, in the original box, and with the original packing and accessories. Chauvet will not issue call tags.
- Call Chauvet and request a Return Merchandise Authorization (RMA) number before shipping the product. Be prepared to provide the model number, serial number, and a brief description of the cause(s) for the return.
- Clearly label the package with an RMA number. Chauvet will refuse any product returned without an RMA number.
- Write the RMA number on a properly affixed label. DO NOT write the RMA number directly on the box.
Once you have the RMA number, provide the following information on a piece of paper and place it inside the box:
- Your name
- Your address
- Your phone number
- RMA number
- A brief description of the problem
Be sure to pack the product properly. Any shipping damage resulting from inadequate packaging will be your responsibility. FedEx packing or double- boxing are recommended.
- Chauvet reserves the right to use its own discretion to repair or replace the returned product(s).
CONTACT US
Chauvet World Headquarters
- Address: 5200 NW 108th Ave. Sunrise, FL 33351
- Voice: 954-577-4455
- Fax: 954-929-5560
- Toll Free: 800-762-1084
- Voice: 844-393-7575
- Fax: 954-756-8015
- Email: chauvetcs@chauvetlighting.com
- Website: www.chauvetprofessional.com.
Chauvet Europe Ltd
- Address: Unit 1C Brookhill Road Industrial Estate Pinxton, Nottingham, UK NG16 6NT
- Voice: +44 (0) 1773 511115
- Fax: +44 (0) 1773 511110
- Email: UKtech@chauvetlighting.eu
- Website: www.chauvetprofessional.eu
Chauvet Europe BVBA
Chauvet France
- Address: 3, Rue Ampère 91380 Chilly-Mazarin France
- Voice: +33 1 78 85 33 59
- Email: FRtech@chauvetlighting.fr
- Website: www.chauvetprofessional.eu
Chauvet Germany
- Address: Bruno-Bürgel-Str. 11 28759 Bremen Germany
- Voice: +49 421 62 60 20
- Email: DEtech@chauvetlighting.de
- Website: www.chauvetprofessional.eu.
Chauvet Mexico
- Address: Av. de las Partidas 34 – 3B (Entrance by Calle 2) Zona Industrial Lerma Lerma, Edo. de México, CP 52000
- Voice: +52 728-690-2010
- Email: servicio@chauvet.com.mx
- Website: www.chauvetprofessional.mx
Visit the applicable website above to verify our contact information and instructions to request support. Outside the U.S., United Kingdom, Ireland, Benelux, France, Germany, or Mexico, contact the dealer of record.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>