MEAN WELL CSP-3000 Series 3000W Power Supply with Single Output Instruction Manual
- June 4, 2024
- MEAN WELL
Table of Contents
MEAN WELL CSP-3000 Series 3000W Power Supply with Single Output
Dimension
Features
- AC input 180-264VAC
- Built-in active PFC function
- High efficiency up to 93%
- Forced air cooling by built-in DC fans
- Output voltage / current programmable
- Active current sharing up to 9000W(2+1)
- Built-in remote ON-OFF control/auxiliary power/ power OK signal
- Protections: Short circuit/ Overload/ Over voltage /Over temperature/ Fan failure
- Conformal coating
- 5 years warranty
Applications
- Factory control or automation apparatus
- Test and measurement instrument
- Laser related machine
- UV curing equipment
- Fish lamp
- Burn-in facility
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx.
Description
CSP-3000 is a 3KW single-output enclosed type AC/DC power supply. This series operates for 180-264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by the built-in fan with fan speed control, working for the temperature up to 65 C. Moreover, CSP-3000 provides vast design flexibility by equipping various built-in functions such as output programming, active current sharing, remote ON-OFF control, auxiliary power, etc.
Model Encoding/ Order Information
SPECIFICATION
MODEL | CSP-3000-120 | CSP-3000-250 | CSP-3000-400 |
---|
OUTPUT
| DC VOLTAGE| 120V| 250V| 400V
RATED CURRENT| 25A| 12A| 7.5A
CURRENT RANGE| 0 ~ 25A| 0 ~ 12A| 0 ~ 7.5A
RATED POWER| 3000W| 3000W| 3000W
RIPPLE & NOISE (max.) Note.2| 800mVp-p| 1000mVp-p| 1200mVp-p
CONSTANT CURRENT REGION| 90 ~ 120V| 125 ~ 250V| 200 ~ 400V
VOLTAGE TOLERANCE Note.3| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 1000ms, 80ms / 230VAC at full load
HOLD UP TIME (Typ.)| 10ms at full load
INPUT
| VOLTAGE RANGE Note.4| 180 ~ 264VAC 254 ~ 370VDC
FREQUENCY RANGE| 47~63Hz
POWER FACTOR (Typ.)| PF≧0.95/230VAC at full load
EFFICIENCY (Typ.)| 92%| 92.5%| 93%
AC CURRENT (Typ.)| 20A/180VAC 16A/230VAC
INRUSH CURRENT (Typ.)| Cold start 60A/230VAC
LEAKAGE CURRENT| <0.3mA / 240VAC
PROTECTION
| SHORT CIRCUIT| Shut down and latch off o/p voltage, re-power on to
recover
OVER CURRENT| 105 ~ 120% rated output power
User adjustable continuous constant current limiting or constant current
limiting with delay shutdown after 3 seconds, re-power on to recover (Please
refer to the Function Manual)
OVERVOLTAGE| 127 ~ 150V| 265 ~ 315V| 420 ~ 500V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after
temperature goes down or re-power on to recover
FUNCTION
| OUTPUT VOLTAGE PROGRAMMABLE(PV)| Please refer to the Function Manual.
OUTPUT CONSTANT CURRENT
PROGRAMMABLE(PC)
| Please refer to the Function Manual.
CURRENT SHARING| Please refer to the Function Manual.
AUXILIARY POWER(AUX)| 12V@0.4A
REMOTE ON-OFF CONTROL| Please refer to the Function Manual
ALARM SIGNAL OUTPUT| Power OK signal. Please refer to the Function
Manual
ENVIRONMENT
| WORKING TEMP.| -20 ~ +65℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.05%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC
(Note 5)
| SAFETY STANDARDS| UL62368-1,Dekra seal BS EN/EN62368-1, EAC TP TC004,
GB4943.1
WITHSTAND VOLTAGE| I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/
70% RH
EMC EMISSION
| Parameter| Standard| Test Level / Note
Conducted| BS EN/EN55032(CISPR32)| Class A
Radiated| BS EN/EN55032(CISPR32)| Class A
Harmonic Current| BS EN/EN61000-3-2| —–
Voltage Flicker| BS EN/EN61000-3-3| —–
EMC IMMUNITY
| BS EN/EN55035 ,BS EN/EN61000-6-2
Parameter| Standard| Test Level / Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air ; Level 2, 4KV contact
Radiated| BS EN/EN61000-4-3| Level 3
EFT / Burst| BS EN/EN61000-4-4| Level 3
Surge| BS EN/EN61000-4-5| Level 3, 2KV/Line-Earth ; Level 2, 1KV/Line-Line
Conducted| BS EN/EN61000-4-6| Level 3
Magnetic Field| BS EN/EN61000-4-8| Level 4
Voltage Dips and Interruptions| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30%
dip 25 periods,
95% interruptions 250 periods
OTHERS
| MTBF| 721.1K hrs min. Telcordia SR-332 (Bellcore) ; 80.5K hrs
min. MIL-HDBK-217F (25℃)
DIMENSION| 278177.863.5mm (LWH)
PACKING|
-
All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25C of ambient temperature.
-
In the PV Mode: Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation. -
Turn off the output when input voltage is less than 160VAC.
The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 720mm’360mm metal plate with 1mm of thickness. The final equipment must be re- confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMl testing of component power supplies.” (as available on http://www.meanwell.com) -
The ambient temperature derating of 3.5 C/1000m with fanless models and of 5C/1000m with fan models for operating altitude higher than 2000m(6500ft
|
Block Diagram
Static Characteristics
Derating Curve
Efficiency vs Load (400V Model)
DRIVING METHODS OF LED MODULE
I-V Operating Area(for PC mode only)
- CSP-3000-120CSP-3000-120
- CSP-3000-250
- CSP-3000-400
Function Manual
- Output Voltage/Current Programming
- Mode Setting
CN1:
CONDITION | MODE | FUNCTION |
---|
PIN5/PIN6
| SHORT| PV MODE| Output Voltage Programming
OPEN| PC MODE| Output Current Programming
The factory default settings: PV mode output max voltage pin5/pin6 short by jumper cap. When pull out the jumper cap,the default settings: PC mode output max constant current.
PV/PC Set adjustment
- Adjust the resistance(SVR2) can set output voltage or constant current point, the adjusting range is 20%-100% of max voltage or max constant current point.
- In the CN2, pin5/pin6 access external 10V voltage signal or 500-1KHz PWM signal can adjust the output voltage or constant current point.
CN2:PIN5/PIN6 needs to operate with a 10V sinking signal or PWM signal, Max. sink current TmA.
MODEL | 120V | 250V | 400V |
---|---|---|---|
PV range | 18 ~ 120V(max.) | 37.5 ~ 250V(max.) | 60 ~ 400V(max.) |
PC range | 2.4 ~ 30A(max.) | 1.4~ 17A(max.) | 0.8 ~ 10A(max.) |
Remote ON-OFF
- Remote ON-OFF is activated by the configuration with respect to CN1 as shown in the following diagram.
Example 2.2(A): Using external voltage source
Example 2.2(B): Using internal 12V auxiliary output
Example 2.2(C): Using internal 12V auxiliary output
Connection Method
Example 2.2(A) | Example 2.2(B) | Example 2.2(C) | |
---|---|---|---|
SW Logic | Power supply output ON | SW Open(open) | SW Open(open) |
Close(short)
Power supply output OFF| SW Close(short)| SW Close(short)| SW Open(open)
Alarm Signal Output
Alarm signal is sent out through “P OK” & “P OK GND” and P OK2 & P OK GND2 pins on CN1. Please acknowledge an external voltage source is required for this function.
Function| Description| Output of alarm(P OK, Relay Contact)| Output of alarm(P
OK2, TTL Signal)
---|---|---|---
__
P OK
| The signal is “Low” when the power supply is above 80% of the rated output voltage, or, say, Power OK| Low
(0.5V max at 500mA)
| Low
(0.5V max at 10mA)
The signal turns to be “High” when the power supply is under 80% of the rated output voltage, or, say, Power Fail| High or open
(External applied voltage, 500mA max.)
| High or open
(External applied voltage, 10mA max.)
Explanation of alarm
Select Overload Protection Type
- Insert the shorting connector on CN1 that is shown in Fig 4.1, the Overload Protection Type will be “constant current limiting with delay shutdown after 3 seconds, re-power on to recover”. This is the factory default.
- Remove the shorting connector on CN1 that is shown in Fig 4.2, the Overload Protection Type will be “continuous constant current limiting”.
Current Sharing
CSP-3000 has the built-in active current sharing function and can be connected in parallel, up to 3 units, to provide higher output power as exhibited below:
- The power supplies should be paralleled using short and large diameter wiring and then connected to the load.
- The difference in output voltages among parallel units should be less than 0.2V(Can Fine tune by SVR1).
- The total output current must not exceed the value determined by the following equation:
- Maximum output current at parallel operation=(Rated current per unit)×(Number of unit)×0.9
- When out current<( 50% rate current)×(Number of unit), the current shared among units may not be fully balanced.
- CS+/CS- on CN1 are connected mutually in parallel(Note:CS+/CS- do not reverse connection).
- Under parallel operation, the “PV/PC” function is not available.
Mechanical Specification
Mounting Instruction
Hole No.| Recommended Screw Size| MAX. Penetration Depth L| Recommended
mounting torque
---|---|---|---
1| M4| 5mm| 7~10Kgf-cm
Control Pin No. Assignment (CN1) : HRS DF11-10DP-2DS or equivalent
Mating Housing | HRS DF11-10DS or equivalent |
---|---|
Terminal | HRS DF11-**SC or equivalent |
Pin No. | Function |
--- | --- |
1 | RCG |
2 | P-OK-2 |
3 | RC |
4 | P-OK-GND-2 |
5 | GND |
6 | Mode |
7 | P-OK |
8 | CS+ |
9 | P-OK GND |
10 | CS- |
Control Pin No. Assignment (CN2) : HRS DF11-8DP-2DS or equivalent
Mating Housing | HRS DF11-8DS or equivalent |
---|---|
Terminal | HRS DF11-**SC or equivalent |
Pin No. | Function |
--- | --- |
1 | 12V AUXG |
2 | 12V AUX+ |
3 | NC |
4 | NC |
5 | PV/PC+ |
6 | PV/PC- |
7 | NC |
8 | NC |
Note: NC pins, please keep open circuit and do not connect to other pins/signals.
LED status indication
AC Input Terminal Pin No. Assignment
DC Output Terminal Pin No. Assignment
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>