ThermoWorks ETI-222-213 Reference Thermapen Instruction Manual
- June 7, 2024
- ThermoWorks
Table of Contents
Reference Thermapen®
Operating Instructions
INSTRUMENT OPERATION
Reference Thermapen is switched on by unfolding the probe until the display
shows the temperature. The instrument is turned off by folding the probe back
into the side of the instrument. The probe should not be rotated more than 180
degrees as damage will occur. It is recommended to store the probe, in the
closed position, when not in use.
Apply the probe to the substance to be measured. For optimum accuracy immerse
at least 2.75″ (70mm) of the probe in the substance. DO NOT immerse the probe
all the way to the plastic rotating hub. The probe should be allowed adequate
time to stabilize to the temperature of the item to be measured.
INSTRUMENT CONFIGURATION
Reference Thermapen has four user-selectable slide switches (switch bank), adjustable with a paperclip, and a single push button ‘Trim Adjust’ which is located under the battery cover.
Switch 1 – Display Units – Changes display units between °F (factory default)
and °C. To change to °C push the switch toward the batteries.
Switch 2 – Resolution – To change the resolution from 0.01°F (factory default)
to 0.1°F push the switch away from the batteries.
Switch 3 – Auto-off – To disable the auto-off (factory default – 10 minutes)
push the switch away from the batteries.
Switch 4 – Reading Trim – For normal use, we do not recommend using the ‘Trim
Adjust’. For further details visit
www.thermoworks.com.
INSTRUMENT CLEANING
Clean the instrument regularly with an anti-bacterial probe wipe to avoid potential bacterial growth.
BATTERY REPLACEMENT
A battery symbol indicates that the batteries will need replacing. The instrument continues to measure accurately but we recommend that the batteries be changed as soon as possible. To replace the batteries, remove the battery cover using a coin (U.S. quarter works best). Remove the batteries by pulling the battery retaining clip back while holding the unit upside down. Replace both batteries, positive side up, replace the cover.
ERROR MESSAGES
‘Err’ will be displayed if the probe develops a fault. If the error message
remains, contact ThermoWorks Tech Support for further assistance.
EMC/RFI
Instrument performance may be affected if operated within a high-frequency
radio field, such as near a mobile phone, or if subjected to an electrostatic
shock.
WARNING
IPA and other solvents may cause damage to the case and screen of this
instrument.
GUARANTEE
This instrument carries a two-year warranty against defects in either
components or workmanship. During this period, products that prove to be
defective will, at the discretion of ThermoWorks, be either repaired or
replaced without charge. This warranty does not apply to probes, where a six-
month period is offered. Full details of liability are available within
ThermoWorks’ Terms & Conditions of Sale at www.thermoworks.com/product-
warranty.
SPECIFICATIONS
Range: –94.00 to 392.00°F (–69.99 to 199.99°C)
Resolution: 0.01° or 0.1° – user selectable
Accuracy: ±0.10°F (±0.05°C) from 32 to 212°F (0 to 100°C), otherwise
±0.36°F (±0.2°C)
Sensor Type: 1/3 DIN Thin Film PT100 to BS EN 60751 (4 wire)
Probe: 4.25 L x 0.125 inches dia. (108 L x 3.3mm dia.)
Auto-Off: 10 minutes – user-selectable
Environmental Range: 32 to 122°F (0 to 50°C)
Battery: 2 x 3 volt CR2032 lithium coin cell, 1000 hours
Display :0.83 H x 1.89 W inches (21 H x 48 W mm) LCD
Dimensions : 6.1 H x 1.85 W x 0.75 D inches (153 H x 47 W x 19 D mm)
Weight: 0.22lb. (100g)
Calibration: UKAS Accredited Certificate included
ACCESSORIES/RELATED ITEMS
For warranty, service, and technical assistance, please contact ThermoWorks’ Technical Support at 801-756-7705 or email at techsupport@thermoworks.com.
| Utah, U.S.A.
Phone: 801-756-7705
Fax: 801-756-8948
www.thermoworks.com|
---|---|---