ThermoWorks Therma K / Therma K-Plus Instructions
- June 7, 2024
- ThermoWorks
Table of Contents
ThermoWorks Therma K / Therma K-Plus Instructions
MODEL ORDER CODE
Therma K 221-041
Therma K-Plus 221-051
SPECIFICATIONS
GUARANTEE – This instrument carries a two-year warranty against defects
in either components or workmanship. During this period, products that prove
to be defective will, at the discretion of Thermo Works, be either repaired or
replaced without charge. This warranty does not apply to probes, where a six-
month period is offered. Full details of liability are available within
ThermoWorks’ Terms & Conditions of Sale at www.thermoworks.com/ product-
warranty.
For warranty, service, and technical assistance, please contact ThermoWorks’
Technical Support at 801-756-7705 or
email at techsupport@ thermoworks.com.
ACCESSORIES/RELATED ITEMS
Operating Instructions
INSTRUMENT OPERATION – Where applicable, connect a probe via the socket
located at the top of the instrument. Switch the instrument on and apply the
tip of the probe to the substance or medium to be measured. The instrument
reading may take a few seconds to stabilize, depending on the nature of the
measurement and sensitivity of the probe.
HOLD (Therma K-Plus) – Press the HOLD/°C/°F button to freeze the display.
AUTO OFF – The instrument will switch off automatically after 10 minutes. To
disable auto off (Therma K-Plus) press down the BACKLIGHT button while
switching on the instrument (this is reset when the instrument is switched
off).
CHANGE FROM FAHRENHEIT TO CELSIUS – Press and hold the “ON/OFF” (Therma
K-Plus: HOLD) button for 5 seconds at startup and the displayed temperature
will change from °F and °C.
OPEN CIRCUIT/FAULTY PROBE – If the probe has developed an ‘Open Circuit’
fault the instrument will display ‘Err’.
BACKLIGHT (Therma K-Plus) – Press the backlight button and the display
will illuminate. Press again and the backlight will turn off. The backlight
will turn off automatically after 20 seconds to preserve battery life.
SENSORS – This instrument should only be used with type K (Nickel
Chromium/Nickel Aluminium) thermocouple probes (to BS EN 60584-2) fitted with
miniature type K thermocouple plugs, where applicable (to BS EN 50212).
BATTERY REPLACEMENT – The instrument will display ‘LO BAT’ to warn that
the batteries will need changing soon. The instrument continues to measure
accurately but after further usage the instrument will display ‘flat bat’ and
shutdown. Replace the batteries with three AAA batteries located under the
rear cover that is held in place by a single screw.
CALIBRATION TRIM (Therma K-Plus)
Visit www.thermoworks.com/therma-k-plus for instructions.
INSTRUMENT CLEANING – Clean the instrument regularly with an anti-
bacterial probe wipe to avoid potential food-borne bacteria growth.
WARNING – IPA and other solvents may cause damage to the case of this
instrument.