UBIQUITI ER-X-SFP EdgeRouter X SFP User Guide
- June 6, 2024
- UBIQUITI
Table of Contents
- Installation Requirements
- Hardware Overview
- Hardware Installation
- Connecting Ethernet
- Connecting SFP (Optional)
- Accessing the EdgeOS Configuration Interface
- Static IP Address
- UNMS Management
- Configuring PoE Settings
- Specifications
- Safety Notices
- Electrical Safety Information
- Limited Warranty
- Compliance
- Documents / Resources
ER-X-SFP Quick Start Guide
Installation Requirements
- For indoor applications, use Category 5 (or above) UTP cabling approved for indoor use.
- For outdoor applications, shielded Category 5 (or above) cabling should be used for all wired Ethernet connections and should be grounded through the AC ground of the power supply.
We recommend that you protect your networks from harmful outdoor environments and destructive ESD events with industrial-grade, shielded Ethernet cable from Ubiquiti. For more details, visit: ui.com/toughcable
Note: Although the cabling can be located outdoors, the EdgeRouter itself should be housed inside a protective enclosure.
Hardware Overview
1. Power LED
Off| Power Off
Green| Power On
2. Link/Activity LED (eth5 Port)
Off| No Link
Green| 100/1000 Mbps (1 Gbps) Link
Flashing Indicates Activity
3. PoE LED (eth0 – eth4 Ports)
Off| No PoE
Green| 24V Passive
4. Link/Activity LED (eth0 – eth4 Ports)
Off| No Link
Green| 10/100/1000 Mbps Link
Flashing Indicates Activity
5. eth5/SFP Port
The SFP port is hot-swappable and supports a 100 Mbps or Gigabit ber SFP
module.
6. eth0 – eth4 Ports
RJ45 ports support passive 24V PoE output and 10/100/1000 Ethernet
connections.
7. Reset Button
Click here to learn how to reset the EdgeRouter to factory
defaults.
ESD grounding for enhanced ESD protection. The ground wire and screw with the
washer are not included (recommended screw size: M3-0.5 x 4 mm).
Power Port
Connect the Power Adapter.
Hardware Installation
Connecting Power
Connecting Ethernet
Note: PoE is disabled by default.
Connecting SFP (Optional)
For information about compatible ber SFP modules, visit ubnt.link/SFP_DAC_Compatibility
Accessing the EdgeOS Configuration Interface
The EdgeOS® configuration interface can be accessed via DHCP or static IP address assignment. By default, eth1 is set up as a DHCP client, while eth0 is assigned a static IP address of 192.168.1.1. To configure the EdgeRouter, proceed to the appropriate section: DHCP or “Static IP Address”.
DHCP
-
Connect an Ethernet cable from eth1 on the EdgeRouter to a LAN segment that has an existing DHCP server.
-
To check the IP address of the EdgeRouter, use one of the following methods:
• Set up the DHCP server to provide a specic IP address to the EdgeRouter based on its MAC address (on the label).
• Let the EdgeRouter obtain an IP address and then check the DHCP server to see which IP address was assigned. -
. Launch your web browser. Enter the appropriate IP address in the address eld. Press enter (PC) or return (Mac).
-
Enter ubnt in the Username and Password elds. Read the Ubiquiti License Agreement, and check the box next to I agree to the terms of this License Agreement to accept it. Click Login.
The EdgeOS Configuration Interface will appear, allowing you to customize your
settings as needed. For more information, refer to the EdgeOS User Guide,
which is available at
ui.com/download/edgemax
For more information on PoE configuration, refer to “Configuring PoE
Settings”.
Static IP Address
-
Connect an Ethernet cable from the Ethernet port on your computer to the port labeled eth0 on the EdgeRouter.
-
Configure the Ethernet adapter on your host system with a static IP address on the 192.168.1.x subnet.
-
Launch your web browser. Type https://192.168.1.1 in the address eld, and press enter (PC) or Return (Mac).
-
Enter ubnt in the Username and Password fields. Read the Ubiquiti License Agreement, and check the box next to I agree to the terms of this License Agreement to accept it. Click Login.
The EdgeOS Configuration Interface will appear, allowing you to customize your
settings as needed. For more information, refer to the EdgeOS User Guide,
which is available at
ui.com/download/edgemax
For more information on PoE configuration, refer to “Configuring PoE
Settings”.
UNMS Management
You can also manage your device using the Ubiquiti Network Management System. UNMS™ lets you congure, monitor, upgrade, and back up your devices using a single application. Get started at www.unms.com
Configuring PoE Settings
The PoE setting for ports eth0-eth4 is set to Off by default.
WARNING: Before activating 24V passive PoE, ensure that the connected device supports PoE and the supplied voltage.
-
On the Dashboard screen, go to Actions > PoE for the interface you want to configure.
-
Select Off or 24V from the PoE drop-down menu.
-
Click Save.
For more information, refer to the EdgeOS User Guide, which is available at ui.com/download/edgemax
Specifications
ER-X-SFP
Dimensions| 142 x 75 x 23 mm (5.59 x 2.95 x 0.91″)
Weight| 215 g (7.58 oz)
Max. Power Consumption| 5W
Max. Total PoE Output| 50W @ 24V
PoE Output| Passive 24V (Pins 4, 5+; 7, 😎
Power Input| 24VDC, 2.5A Power Adapter (Included)
Power Supply| External AC/DC Adapter
Supported Voltage Range| 9 to 30VDC
Button| Reset
LEDs| Power, Link/Activity (6), PoE (5)
Processor| Dual-Core 880 MHz, MIPS1004Kc
System Memory| 256 MB DDR3 RAM
Code Storage| 256 MB NAND
Wall-Mount| Yes
Networking Interfaces Data/PoE Passthrough Port Data Port| (5) 10/100/1000
RJ45 Port
(1) 100/1000 SFP Port
Operating Temperature| -10 to 45° C (14 to 113° F)
Operating Humidity| 10 – 90% Noncondensing
Certi cations| CE, FCC, IC
Safety Notices
- Read, follow, and keep these instructions.
- Heed all warnings.
- Only use attachments/accessories specified by the manufacturer.
WARNING: To reduce the risk of re or electric shock, do not expose this product to rain or
WARNING: Do not use this product in a location that can be submerged by water.
WARNING: Avoid using this product during an electrical storm. There may be a remote risk of electric shock from lightning.
Electrical Safety Information
- Compliance is required with respect to voltage, frequency, and current requirements indicated on the manufacturer’s label. Connection to a different power source than those specified may result in improper operation, damage to the equipment, or pose is a hazard if the limitations are not followed.
- There are no operator serviceable parts inside this equipment. Service should be provided only by a qualified service technician.
- This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet.
a. Do not substitute the power cord with one that is not the provided approved type. Never use an adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding wire.
b. The equipment requires the use of the ground wire as a part of the safety certification, medication or misuse can provide a shock hazard that can result in serious injury or death.
c. Contact a qualified electrician or the manufacturer if there are questions about the installation prior to connecting the equipment.
d. Protective earthing is provided by a Listed AC adapter. Building installation shall provide appropriate short-circuit backup protection.
e. Protective bonding must be installed in accordance with local national wiring rules and regulations.
Limited Warranty
ui.com/support/warranty
The limited warranty requires the use of arbitration to resolve disputes on an
individual basis, and, where applicable, specify arbitration instead of jury
trials or class actions.
Compliance
FCC
Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions.
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the required to correct the interference at his own expense.
CAN ICES-3(A)/NMB-3(A)
Australia and New Zealand
Warning: This equipment is compliant with Class A of CISPR 32. In a residential environment, this equipment may cause radio interference.
CE Marking
CE marking on this product represents the product is in compliance with all
directives that are applicable o it.
WEEE Compliance Statement
Declaration of Conformity
Online Resources
© 2020 Ubiquiti Inc. All rights reserved.
Documents / Resources
|
UBIQUITI ER-X-SFP EdgeRouter X
SFP
[pdf] User Guide
ER-X-SFP, EdgeRouter X SFP
---|---
References
- Ubiquiti - Rethinking IT
- Ubiquiti - Warranty
- UniFi - Rethinking IT - Ubiquiti
- Ubiquiti | UISP | A Last Mile Revolution
- Ubiquiti | UISP | A Last Mile Revolution
- community.ubnt.com/
- WEEE Compliance Statement
- UniFi - Introduction - Ubiquiti
- Software Downloads - Ubiquiti
- Software Downloads - Ubiquiti
- Ubiquiti - Warranty
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>