kogan KADPMSCMSGA Active pro Deep Muscle Massege Gun User Guide
- June 6, 2024
- Kogan
Table of Contents
User Guide
Active pro-Deep Muscle Massage Gun
KADPMSCMSGA
SAFETY & WARNINGS
To reduce the risk of malfunction, electric shock, injury, fire, death, and equipment damage, please read all instructions and warnings in this user guide carefully before using this product
- This device is not suitable for children.
- If you currently have any muscular injuries, consult your doctor before using this
- Ensure the skin is clean and dry before use.
- Do not massage the same area for longer than 60 seconds.
- Do not use above the neck or on areas with little muscle coverage.
- Do not use it on bones.
- This product is suitable only for the soft tissues of the body.
- Close use if bruising. pain or discomfort occurs.
- Do not place any objects in the ventilation holes of the product
- Do not immerse the product in water, and do not allow water to enter the ventilation holes of the product.
- Keep this device away from fire and other sources of heat.
- Do not intentionally drop this product.
- Do not use other chargers for charging. You must use the charger supplied with your product
- After charging is complete, unplug the charger.
- The product cannot be used while charging.
- Please use this product only os described in this user guide.
- Do not dismantle or modify this product in any way.
- Do not place fingers, hair, or other parts of the body near the short and back of the message header, as they may be pinched.
Do not touch this part when starting the machine without the massage head installed.
Do not touch this part when starting the machine with the massage head installed
Important
This product cannot be used without your doctor’s prior consent in any of the following situations:
- pregnancy
- complications of diabetes (such as neuropathy or retinal damage),
- currently fitted with a pacemaker
- undergone recent surgery
- epilepsy or migraine
- disc herniation
- spine advancement
- vertebral detachment
- spinal joint stiffness
- recent joint replacement surgery
- currently fitted with an IUD, metal needle or steel plate for any health-related issues.
OVERVIEW
OPERATION
Charging
- Before initial use, charge for four hours to fully charge the battery.
- When charging, connect the DC end of the supplied adapter to the charging port, and plug the adapter into a 100-240V power outlet.
- The LED light on the device flashes regularly, showing the battery level, indicating that it is charging.
Battery Indicator Status | Battery Level |
---|---|
The first indicator is on | 20-35% |
The second indicator is on | 40-60% |
The third indicator is on | 65-80% |
Forth indicator is on | 85-100% |
- The battery can be charged at any time and at any power level, and the device cannot be operated while charging.
- When the battery is to less than 5%, the first indicator will flash. Cease use and charge the massager.
- The average running time of the product when it is fully charged is about 3 hours. This may be affected by the gear level used and the pressure applied.
Using the Massage Gun
- Press the power button to enter the first gear and press the “+” & “-” buttons to change the speed level/gears. Each time you press the “+” button, the gear will increase by one gear until it reaches 10.
- Intelligent protection: after 10 minutes of continuous use, the device will need to be restarted before it can be used.
Installation of Massage Heads
- To install massage heads, rotate the massage head slightly while pushing in.
- To remove massage heads, rotate the massage head slightly while pulling out.
- With exception to the Forkhead do not install or remove massage heads directly without rotating.
When installing the Forkhead attachment, once the inside of the horizontal line alignment line (the red line in the figure) is aligned with the machine, as shown below, it indicates that it is in place. If there is a gap between the line and the machine, there is a risk of falling off during use
CLEANING & CARE
Clean the device with a damp cloth and then dry it with a soft cloth.
- When storing or traveling, put it in the package provided.
- Store the product in a dry, well-ventilated place free of corrosive materials.
- If this device is not being used for an extended period, it should be stored in original packaging and recharged every 6 months.
- Ensure this product is secure during transportation to prevent damage.
MASSAGE GUIDE
Brachioradialis | 10-15s x 3 times |
---|---|
Flexor carpi radialis | 10-15s x 3 times |
Palmaris longus | 12-15s x 3 times |
Flexor carpi ulnaris | 10-15s x 3 times |
Extensor digitorum | 5-10s x 3 times |
Extensor carpi radial’s longus | 5-10s x 3 times |
Extensor carpi radialis brevis | 5-10s x 3 times |
Bicipital muscle of arm | 12-20s x 3 times |
Brachia lis | 12-20s x 3 times |
Deltoid | 12-20s x 3 times |
Pectoral’s major | 12-20s x 3 times |
Triceps | 15-20s x 3 times |
---|---|
Rhomboids | 20-30s x 3 times |
Upper Trapezius | 15-20s x 3 times |
Middle Trapezius | 15-20s x 3 times |
Lower Trapezius | 15-20s x 3 times |
Musculus supraspinatus | 10-15s x 3 times |
Levator Scapulae | 10-12s x 2 times |
Big circular muscle biceps brachii | 10-12s x 2 times |
Small circular muscle biceps brachii | 10-12s x 2 times |
Musculus infraspinatus | 10-125 x 2 times |
Advice: Massage the muscles from the middle to the sides, from top to bottom.
Erector spinae (waist) | 30-60s x 4 times |
---|---|
Latissimus dorsi | 30-60s x 4 times |
Thoracolumbar fascia | 40-60s x 3 times |
Psoas major | 30-60s x 3 times |
Abdominal oblique muscle | 10-15s x 2 times |
Vertical spinal muscle (thoracic segment) | 15-20s x 2 times |
Lumbar square muscle | 20-30s x 2 times |
Iliopsoas muscle | 20-30s x 3 times |
Gluteus maximus | 30-60s x 4 times |
Gluteus medius | 30-60s x 4 times |
Piriformis | 60-90s x 1 time |
Advice: Massage the muscles from the middle to the sides, from top to bottom. Large muscle groups can run along with the muscles.
Biceps femoris | 20-30s x 3 times |
---|---|
Semitendinosus muscle | 20-30s x 3 times |
Semimembranosus | 20-30s x 2 times |
Gracilis | 10-15s x 2 times |
Short adductor | 10-15s x 2 times |
Long adductor | 10-15s x 2 times |
Rectus femoris | 30-45s x 2 times |
Vastus Lateral’s | 30-45s x 2 times |
Vastus medialis | 30-45s x 2 times |
Whip muscle | 30-45s x 1 time |
Tensor fascia lath | 15-20s x 2 times |
Advice: Massage the muscles from top to bottom.
Gastrocnemius | 20-30s x 3 times |
---|---|
Soleus muscle | 20-30s x 3 times |
Tibialis anterior muscle | 15-20s x 2 times |
Peroneus longus | 15-20s x 2 times |
Peroneus Brevis | 15-20s x 2 times |
Fascia planters | 20-30s x 3 times |
Advice: Massage the muscles from top to bottom.
SPECIFICATIONS
Product Net Weight | 0.8kg |
---|---|
Input voltage | 100-240V – 50 / 60Hz |
Interface type | DC 16.8V = 0.8A |
Battery capacity | 2000mAh |
Gear strength | 12 speeds to adjust |
Charging time | 3 hours |
Power supply | Rechargeable lithium-ion battery |
Operating environment | 0 – 40°C |
Dimensions | 188 x 62 x 238mm |
This marking indicates that this appliance should not be disposed of with other household wastes. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources.
Name and Content of Noxious Substances in Product
At the end of the product life, please do not discard it with general household waste. Put this product in the government-designated recycling bin or send this product to the manufacturer’s after-sales service center so to handle it in an environmentally friendly way.
Parts name | Toxic and Noxious Substances or Elements |
---|---|
Pb | Hg |
Product Shell | 0 |
Circuit Board | X |
Component | |
Metallic Parts | 0 |
Rubber parts | 0 |
Adapter | X |
Connection Line | 0 |
Handle Cover | 0 |
This form is prepared in accordance with SJ FT 11364
X: Circuit Board components include printed circuit board machine components,
such as resistors, capacitors, integrated circuits, connectors, etc.
0: indicates that the content of noxious substances in all homogeneous
materials of the part is below the limit requirement specified in GB/ T 26572.
X: Indicates that the content of noxious substances in at least one of the
homogeneous materials of the part exceeds the limit requirement by GB/T26572.
NOTES……………
Need more information?
We hope that this user guide has given you the assistance needed for a simple
setup. For the most up-to-date guide for your product, as well as any
additional assistance you may require, head online to
help.kogan.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>