BRAUN S6032 Silk Expert Pro 3 User Guide
- June 6, 2024
- Braun
Table of Contents
- Description
- How does it work?
- Contraindications
- Warnings
- Precautions
- Electrical and fire safety
- How to use
- Treatment methods
- How to treat the face (females only)
- Treatment plan
- After treatment
- Cleaning and storage
- Possible side effects
- Troubleshooting
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Braun Infolines
00 800 27 28 64 63
00 800 BRAUNINFOLINE
Type 6032
Braun GmbH
Frankfurter Straße 145
61476 Kronberg/Germany
www.braun.com
www.service.braun.com
suitable
not suitable
Our products are designed to meet the highest standards of quality,
functionality and design.
Using professional light technology, Braun Silk·expert Pro 3 Intense Pulsed
Light (IPL) allows you to permanently remove unwanted, visible hair
comfortably at home. Before using the device, please read the use instructions
carefully, including all contraindications, warnings, and safety information,
and keep them for future reference.
This device has been designed to effect long-term hair growth reduction after
a certain period of treatment. Ideal body areas for use include:
Women: Legs, arms, underarms, bikini area, and face (below cheekbones)
CAUTION : Do not use the device near the eyes and along the forehead.
Men: Shoulders and below (chest, back, arms, stomach, legs)
CAUTION: Do not use on the face, neck or genital area.
Usage on male beards or facial hair may lead to permanent or uneven results
which may produce changes in facial characteristics that may not be desirable.
IPL is not suitable for everyone. It is most effective on light to medium skin
tones and dark hair colors. Please, refer to the skin tone and hair color
chart on page 3 to see if the device is suitable for you.
Description
1. Treatment window
2. SensoAdapt™ skin tone sensors
3. LED Power bars
4. Gentle mode button with indicator
5. Treatment button
6. Handle| 7. Base station
8. Mains cord
9. Glass filter (integrated UV filter)
10. Standard head
11. Precision head (not with all models)
---|---
How does it work?
Braun Silk·expert Pro 3 works beneath the skin surface by targeting the melanin in the hair follicle, helping to break the cycle of hair re-growth. With continued, periodic use, the light energy helps prevent unwanted hair from reaching the skin surface.
The intelligent SensoAdapt™ skin sensors (2) continuously read your skin tone before every flash, automatically adapting the light intensity for best efficacy and safety. This allows treatment of appropriate skin tones but prevents treatment if your skin tone is too dark.
Contraindications
Do not use the device …
- if your skin is darker than skin tone V shown on the skin tone chart on page 3. Since dark skin absorbs more light energy, treating very dark skin may cause discomfort/pain and adverse effects (e.g., burns, blisters, discoloration or scarring) and injure your skin.
- if you are pregnant, lactating, or under the age of 18 as this device has not been tested with these individuals.
- if you have a history of skin cancer or precancerous lesions (e.g., nevi or a large number of moles).
- If your skin has been artificially or naturally tanned recently. Your skin may be sensitive following sun exposure and particularly susceptible to side effects of IPL treatment (e.g. burn, blister, discolor or scar to your skin). Also, avoid unprotected exposure to direct sunlight after your IPL treatment.
Certain conditions can also prohibit the use of this device.
Do not use the device if any of the following applies:
- You have a chronic medical condition.
- You have a chronic skin disease (e.g. psoriasis or vitiligo) or damaged skin (e.g. sunburn, cuts, open wounds or active infections) in the areas you wish to treat.
- You have varicose veins in the area you wish to treat.
- You have a known sensitivity to sunlight (photosensitivity) or are taking medication that may make the skin more sensitive (e.g. Retin A, Accutane, and/or other topical retinoids).
- You have had a professional skin peel treatment on the area you wish to treat.
- You have any of the above, this device may injure your skin or make existing conditions worse. You may experience side effects such as burns, blisters, and skin color changes (hyper- or hypo-pigmentation) or scarring.
If you are unsure whether this device is safe for you to use, please consult
your physician or dermatologist.
If you take any kind of medication regularly and over a long period of time,
please consult your physician for any potential impact on skin sensitivity to
light.
Warnings
Do not use on …
- scalp, eyebrows or anywhere near or around the eyes. Use in these areas may permanently damage your eyes.
- a tattoo or permanent makeup in the treatment area.
- nipples, genitals or around the anus. These areas may have a darker skin color and/or greater hair density and using the device in these areas may cause discomfort/pain or injure your skin.
- dark brown or black spots such as freckles, birthmarks, moles or warts in the treatment area.
- beard / facial hair for men.
Do not look directly into the glass filter (9) or attempt to activate the device toward the eyes. To protect the safety of your eyes and those of individuals nearby, the device will only activate when both skin tone sensors are placed against the skin. If at any time the device activates when both sensors are NOT in contact with the skin, STOP use immediately and contact your retailer. Do not use more than once a week on the same area. This will not speed up the results and may increase the chances of injury to your skin.
Precautions
- The device is intended for a single user.
- It is not intended for use by people under 18 years old.
- People with reduced physical, sensory or mental capabilities or lack of experience and knowledge, may use the device if they have been given supervision or instruction concerning the safe use of the device and understand the hazards involved.
- Children should be supervised to ensure that they do not play with the device. Always keep the device out of children’s reach.
Electrical and fire safety
Regularly check the device and cords for visible signs of damage. In case of damage or cracks, stop using the device. Electric shock may result from using a damaged device. In case of defects, have the device checked and repaired by an authorized service center. Unqualified repair work can lead to extreme hazards for the user. Always unplug the device after use.
DANGER
Never attempt to repair and open the device, as this may expose you to
dangerous electrical components and to pulsed light energy, either of which
may cause serious bodily damage and/or permanent eye injury.
Do not use in or near water and wet surfaces such as bathtubs, showers, basins
or other vessels that may contain water. If the device becomes wet, it should
not be used. Electric shock may result from using a wet device. Do not use if
the device is damaged (e.g. cracked housing, cord damage etc).
Internal parts contain electric charges that are hazardous.
Do not use if the glass filter (9) is cracked or missing. Regularly inspect
the glass filter for damage.
Do not touch the glass filter during or directly after use since it will get
hot.
Do not use petroleum-based or flammable cleaning agents (alcohol, acetones) on
the device as these pose a fire risk.
Do not use abrasive cleaning agents. These may damage the device or scratch
the glass filter.
Do not attempt to use this device other than for removing unwanted hair. Do
not use the device on a surface other than skin. Do not press the treatment
button when the treatment window (1) is not placed in full contact with the
skin.
Do not block the cooling vents. The device may overheat and pose an electric
shock risk or fire hazard.
How to use
Preparing the treatment area
Remove any visible hair on the skin before using the device. You may use your
preferred hair removal method. To keep the treatment window clean and intact,
ensure there is no hair remaining on the skin surface. Clean the treatment
area and pat it dry.
To power on the device:
Use the mains cord (8) to connect the base station to an electrical outlet.
Press the gentle mode button (4) to activate the device. The LED power bars
(3) will light up once and, a fan starts running. This means the device is in
READY mode. During operation, the device will heat up slightly.
Automatic light adaptation
When both skin tone sensors (2) have skin contact, the device reads your skin
tone and selects the appropriate light intensity which is indicated by white
LEDs on the Power bars (3). These confirm that the device is ready to flash.
|
light skin tone → high light intensity
---|---
dark skin tone → low light intensity
no skin contact → device will not flash
invalid skin tone → device will not flash
Gentle mode
Push the gentle mode button (4) to reduce the light intensity. The gentle mode
indicator lights up when it is activated. To deactivate it, press the gentle
mode button again.
The power bars flash to confirm a change in the light intensity setting.
When holding the gentle mode button (4) longer than 3 seconds, the device is
deactivated.
After 10 minutes without use, the device is automatically deactivated.
To reactivate it, press the gentle mode button.
Patch Test
Before your first treatment, we recommend you test your skin for reaction to
Braun Silk·expert on a small area of skin of the body part you plan to treat
(about 2 x 3 cm in size; equivalent to the size of two flashes, side by side).
Perform a patch test as described below in chapter «Treatment methods»,
section «STAMPING». Wait 48 hours to examine the test area. If the skin
appears normal, begin your first treatment. If a skin reaction develops,
discontinue using the device and consult your physician. Do not treat the
patch tested area for at least one week after the test.
Treatment methods
The area to be treated must be hair-free, clean and dry. Before pushing the treatment button, look away from the device to avoid the bright light. In seldom cases, a user may find the flash too bright. However, there is no safety risk associated with this. For increased comfort, we recommend treating in a well-lit room to help reduce the perceived brightness.
GLIDING for fast and efficient treatment of large areas (e.g. legs).
STAMPING for treating small, hard-to-reach areas (e.g. face for females, bikini line, underarms, knee, shin, ankles)
1. Place the treatment window firmly on your skin, ensuring both skin sensors
have skin contact.
The power bars (3) show white LEDs
2. Press and hold the treatment button (5). The device will begin to flash.|
2. Press and instantly release the treatment button (5). The device will emit
a flash.
3. Move the device slowly and continuously from the bottom to the top of the
treatment area. Make sure to always keep full skin contact so that the device
flashes continuously.| 3. Lift off the device and place it onto the next
adjacent spot to be treated. Wait for the power bars to show white LEDs. Then
press and release the treatment button.
Once the gliding stroke is completed, lift the device off the treatment area.
Repeat steps 1-3 to treat the next adjacent area in a parallel stroke.|
Continue treatment spot by spot until you have completed the entire area you
wish to treat.
Make sure you avoid missed areas by placing the treatment window directly next
to the previously treated spot without leaving any space between treated
areas.
If you feel intense pain, stop treatment immediately and consult your
physician before using the device again.
Treatment head(s)
While the standard head (10) can be used on all areas, it is ideal for
efficiently treating large areas, e.g. legs.
The precision head (11) (not with all models) has been specifically designed
for small, curvy, hard-to-reach areas, e.g. face for females, bikini line,
underarms, knee, shin, ankle. With the precision head attached, the flashing
sequence is slower.
How to treat the face (females only)
- Before treating the face, make sure you have done a patch test. Remove any visible hair and cosmetics, lotions and creams from the area you wish to treat.
- Before pressing the treatment button, close your eyes or look away to avoid the bright light. Avoid treating the same area twice as this may increase the chance of producing adverse reactions.
- When treating the upper lip area, avoid contact with the lips and the nostrils. The central area below the nostrils might be sensitive.
- Do not use on permanent / semi-permanent lip liner on the lip margin.
- TIP: You can press your lips together to ensure that the light does not activate on the upper lip itself.
- Hair growth under the chin can be denser and coarser. This can sometimes lead to slight skin reddening following a treatment. This redness is temporary and should completely disappear after 24 hours.
NOTE:
- If redness or a burning sensation occurs and lasts for several minutes, apply a cool cloth/pad to soothe the area.
- If any pigment changes in the skin, e.g., lightening or darkening, are observed, stop using the device.
Seek medical advice to determine the cause which may be due to an underlying medical condition.
Treatment plan
Start-up phase | 1 treatment per week (4-12 weeks) |
---|---|
Maintenance treatment | continues treating to your needs, e.g. every 1-2 |
months.
The typical hair growth cycle varies between individuals and could take up to
16 months depending on body area (underarm, lower leg, bikini area). Since
only hairs in their growing phase are susceptible to treatment with light, it
is important to do multiple treatments to achieve continuously smooth skin.
For this reason, we recommend a start-up phase with one treatment per week
over a period of 4 -12 weeks.
In case you no longer see hair growing, you do not need to complete the full
12 weekly treatments. You can switch to maintenance treatments.
After treatment
Once you have completed your treatment, unplug the power supply from the
electrical outlet. After treatment, we recommend using sunscreen SPF >15
whenever treated areas may be exposed to the sun. We recommend avoiding
exposure to artificial light sources, such as tanning booths or solarium.
Avoid any activity or skin products that may irritate your skin for 24 hours
after treatment. This includes using hot tubs or saunas, wearing tight-fitting
clothing, using bleaching creams, perfumed products or exfoliation products.
The above may cause irritation, such as itching and redness, in the treated
areas.
Cleaning and storage
After each treatment, the skin tone sensors (2) and the treatment window (1)
should be inspected for damage and wiped down with a dry, lint-free cloth. If
any marks or black spots are seen, clean them off straight away. Do not touch
or clean the glass filter (9) immediately after use to allow it to cool down.
Do not rinse or immerse the device in water or any other liquid.
To ensure maximum performance, keep the heads (10, 11) with their built-in
reflectors free from dirt, hair or other debris. Do not clean in water, but
use a dry cloth for cleaning them carefully. Store the device in a cool, dry
place. Make sure the treatment window and skin sensors are protected from
damage.
Possible side effects
Some people will experience slight discomfort (e.g. heat or redness of the skin) when using the device – this is normal. You may feel heat and tingling when activating the flash, followed by redness in the skin. This type of reaction usually disappears within 24 hours. Adverse reactions are usually immediate or appear within 24 hours. In rare cases, they may take up to 72 hours to appear. If you experience abnormal skin reactions please contact your physician.
Side effect | How to assess and react |
---|
Warm feeling or tingling sensations during treatment typically disappears
after a few seconds to a minute and decreases with continued use.| This is
expected and normal for all IPL treatments. You can keep on using the
device as instructed.
Discomfort or pain is intense during treatment or persists after treatment.|
Stop using the device and consult your physician before using it again.
Skin redness during or after treatment which disappears within minutes to
several hours.| This is expected and normal for all IPL treatments. You
can keep on using the device as instructed once skin redness has disappeared.
Skin redness which does not go away within 24 – 48 hours after treatment.|
Stop using the device and consult your physician before using it again.
In very rare cases:|
Swelling and redness around the hair follicle that disappears within two or
three days.| You can keep on using the device as instructed once swelling and
redness around the hair follicle has disappeared.
Swelling and redness around the hair follicle that does not disappear
within two to three days.| Stop using the device and consult your physician
before using it again.
Temporary changes in skin color (lightening or darkening).| If your skin color
changes, stop using the device and consult your physician.
Increase in hair growth in areas of treatment (more likely to be seen with
subjects of Mediterranean descent).| If this increase persists over several
treatments, stop using the device and consult your physician.
Troubleshooting
The following troubleshooting guide may help you solve initial problems you may experience with this device.
Problem | Solution |
---|---|
Power bars do not light up when the treatment window is placed on the skin. |
Make sure the device is connected to an electrical outlet. Press the gentle mode button (4) to activate it.
Ensure both skin tone sensors are in full contact with the skin. If needed, move the device in a way that both skin tone sensors get skin contact.
The device doesn’t work on small areas.| Use the precision head (11) on
small, hard-toreach areas (if available).
Make sure both skin tone sensors are in contact with the skin.
The flashing sequence slows down.| The device is in heat-protection mode. To
get back to normal speed, allow the device to cool down.
On the power bar, only the first LED illuminates red.| Invalid skin tone
reading. Your skin is either too light or too dark. The device will not flash.
Gentle mode indicator is flashing.| The device is deactivated. Press the
gentle mode button to re-activate it.
First LED on the power bars flashes red.| Head (10 or 11) has been taken off.
Re-attach it.
The power bars show an unfamiliar pattern of one red LED shining along with
individual white LEDs.| Device error. The device will not operate.
Unplug and reconnect. If the error persists, contact a Braun Service Centre
for repair.
All white LEDs flash.| End of product lifetime. A maximum number of flashes
(300,000) has been reached.
The device is broken, cracked or appears defective.| Do not use if the
handle, the base station or the main cord is damaged. If you are in any doubt
about the safety or suspect it is damaged in any way, you must not use it.
Disposal
The product contains recyclable electronic waste. To protect the environment,
do not dispose of it in the household waste, but take it to appropriate local
collection points.
Subject to change without notice.
Guarantee
We grant a 2-year guarantee on the product commencing on the date of purchase.
Within the guarantee period, we will eliminate any defects in the appliance
resulting from faults in materials or workmanship, free of charge either by
repairing or replacing the complete appliance at our discretion.
This guarantee extends to every country where this appliance is supplied by
Braun or its appointed distributor.
This guarantee does not cover damage due to improper use, normal wear or use
as well as defects that have a negligible effect on the value or operation of
the appliance. The guarantee becomes void if repairs are undertaken by
unauthorized persons and if original Braun parts are not used.
To obtain service within the guarantee period, hand in or send the complete
appliance with your sales receipt to an authorized Braun Customer Service
Centre (address information available online at
www.service.braun.com).
For UK only:
This guarantee in no way affects your rights under statutory law.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>