HMS CanEasy for Analysis and Test Environment Installation Guide

June 6, 2024
HMS

HMS - LOGOConnecting Devices ™HMS CanEasy for Analysis and Test
Environment - IXXAT LOGO

CanEasy
for Analysis and Test Environment
INSTALLATION GUIDE
4.04.0144.20000 1.0 en-US ENGLISH

HMS CanEasy for Analysis and Test Environment

Important User Information

Disclaimer
The information in this document is for informational purposes only. Please inform HMS Networks of any inaccuracies or omissions found in this document. HMS Networks disclaims any responsibility or liability for any errors that may appear in this document.

HMS Networks reserves the right to modify its products in line with its policy of continuous product development. The information in this document shall therefore not be construed as a commitment on the part of HMS Networks and is subject to change without notice. HMS Networks makes no commitment to update or keep current the information in this document.

The data, examples, and illustrations found in this document are included for illustrative purposes and are only intended to help improve understanding of the functionality and handling of the product. In view of the wide range of possible applications of the product, and because of the many variables and requirements associated with any particular implementation, HMS Networks cannot assume responsibility or liability for actual use based on the data, examples or illustrations included in this document nor for any damages incurred during the installation of the product. Those responsible for the use of the product must acquire sufficient knowledge in order to ensure that the product is used correctly in their specific application and that the application meets all performance and safety requirements including any applicable laws, regulations, codes, and standards. Further, HMS Networks will under no circumstances assume liability or responsibility for any problems that may arise as a result of the use of undocumented features or functional side effects found outside the documented scope of the product. The effects caused by any direct or indirect use of such aspects of the product are undefined and may include e.g. compatibility issues and stability issues.

Product Description

CanEasy is a Windows-based tool for analysis and test environment for CAN, CAN FD, and LIN networks as well as automotive Ethernet, that simulates the bus traffic with a high automatization level and an easy configuration. easy can be used for the analysis of real networks or for simulation of virtual systems and for residual bus simulation in the whole development process, from testing to the parameterization of control units. With plug-ins, various extensions can be realized.
To use CanEasy, an interface to connect CanEasy with the CAN network is necessary (e.g. Ixxat USB-to-CAN).
The following license stages are available:

  • Standard (1.04.0144.00001): CAN, CAN FD, LIN with up to 4 channels
  • Plus (1.04.0144.00002): CAN, CAN FD, LIN with up to 4 channels, rich-panel visualization, and diagnostics (UDS)
  • Professional (1.04.0144.00000): CAN, CAN FD, LIN, automotive Ethernet with up to 99 channels, rich-panel visualization and diagnostics (UDS), error memory display, and CAPL converter

Via the USB dongle, a single CanEasy user license can be enabled.
For a detailed list of the functions of the different license stages and the supported Ixxat PC, interfaces see www.ixxat.com/caneasy.

Installing the Software

To communicate with Ixxat hardware the Ixxat VCI driver must be installed. The VCI driver and the CanEasy can be downloaded from www.ixxat.com/caneasy.

The VCI driver is constantly improved and expanded! Check online if a newer version is available.

► Plugin the USB dongle in the PC that is used for the operation.
► Download the latest VCI driver and the CanEasy ZIP container from www.ixxat.com/caneasy.
► Install the VCI driver on a Windows computer (see Installation Guide VCI Driver).
► Unpack the CanEasyZIP container in a user-defined folder on the local drive.
► Execute the included installation file CanEasy-Installer-Lic.exe.
→ Setup assistant is started.
► Follow instructions in the setup assistant.
► When fantasy is installed, start CanEasy.
► For more information about the available functions of the license in use, select Help in the main menu to open the online help.

Basic Configuration

To start a simulation with CanEasy a database channel must be created and the bus adapter must be connected.
► Make sure, that the required software is installed (see Installing the Software, p. 3).
► Install the hardware (for more information see User Manual of Ixxat interface in use).
► Open CanEasy.

HMS CanEasy for Analysis and Test Environment - Ixxat
interface

Fig. 1
CanEasy
► In the plug-in list (2) right-click entry Database (4) and select New channel and the desired network.
► Define the channel.
→ Database channel is added (4).
► In the plug-in list (2) right-click entry Hardware and select Refresh.
→ Connected bus adapters are detected and displayed with available channels and supported protocols (3).
► To connect the hardware channel and database channel, drag and drop the database channel (4) to the desired hardware channel (3).
► To start the simulation of initializing the bus adapter, click the button Start (1).
→ Sending and receiving CAN messages is possible.

Support/Return Hardware

Support
► For problems or support with the product request support at www.ixxat.com/support.
► If required use supports phone contacts on www.ixxat.com.

Return Hardware
► Fill in the form for warranty claims and repair on www.ixxat.com/support /product-returns.
► Print out the Product Return Number (PRN resp. RMA).
► Pack product in a physically- and ESD-safe way, use original packaging if possible.
► Enclose PRN number.
► Observe further notes on www.ixxat.com.
► Return hardware.

Disposal and recycling

You must dispose of this product properly according to local laws and regulations. Because this product contains electronic components, it must be disposed of separately from household waste. When this product reaches its end of life, contact local authorities to learn about disposal and recycling options, or simply drop it off at your local HMS office or return it to HMS. For more information, see www.hms-networks.com.

© 2020 HMS Industrial Networks
Box 4126
300 04 Halmstad, Sweden
[email protected]
4.04.0144.20000 1.0 en-US / 2020-09-30 / 20139

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

HMS User Manuals

Related Manuals