SDC Z7880 Mortise Lock Instruction Manual

June 6, 2024
SDC

INSTALLATION INSTRUCTIONS
Z7870/72 & Z7880/Z7882
MORTISE LOCK

A. Door Preparation:

  1. Measure desired height from finished floor, mark a horizontal line on door and door edge.

  2. Align template on edge of the door with the applicable horizontal at height line. Check the chart for drilling trim holes on the template and mark only holes for lock function is installed.
    SDC Z7880 Mortise Lock - Door Preparation

  3. Mortise door edge according to measurements on installation template and drill proper holes for trim.

  4. Recess for faceplate, the dimension is: L 8-1/32″ x W 1-5/16″ x D 7/32″.

OPTIONAL
DOOR CORE DRILLING GUIDE

7000-DG

SDC Z7880 Mortise Lock - DOOR CORE DRILLING GUIDE

B. Strike Installation:

  1. Align strike template on the jamb. Be sure to keep 3/8″ distance between lock centerline and strike centerline. Recess 5/32″ for a flush fit of strike and dust box.
  2. Mortise jamb according to the measurement of strike template. Then fit strike and dust box into the frame and secure into place with supplied screws.

C. Install Lock case

  1. Make sure the lock hand matches the door hand, use the following diagram to determine the hand of the door.
    SDC Z7880 Mortise Lock - Install Lockcase

Instructions for changing lock hand:
REX option Locksets are factory set per handing and can’t be changed in the field.

  1. Change latch bolt handing
    If the hand of the latch bolt doesn’t match the door hand, remove the fixing screw and pull the latch bolt out from the lock case. Turn the latch bolt 180 ° to change the handling. Position latch bolts back, into the case and fasten it.
    SDC Z7880 Mortise Lock - Change latchbolt handing

  2. Change hand of lock
    For RH and RHRB, the catch screw will be on the lock case side. For LH and LHRB, the catch screw will be on the lock cover side.
    SDC Z7880 Mortise Lock - Change hand of lock

  3. Connect wires as shown on the lock cover diagram.

  4. Insert lock case into mortise cut-out and fasten screws to door.

SDC Z7880 Mortise Lock - fasten screws to door

D. Install Spindles

  1. Insert spindles as shown
    SDC Z7880 Mortise Lock - Install Spindles

E. Install Lever trim

  1. Place the reversible spring cage onto the ferrules with an arrow pointing in direction of lever rotation.

  2. Install outside trim with mounting posts through door and position lever onto the spindle.

  3. Install inside spring cage onto the spindle with the arrow pointing in the direction of inside lever rotation.

  4. Install inside mounting plate onto the spindle. Tighten with the provided screw.

  5. Cap inside rose over mounting plate.
    SDC Z7880 Mortise Lock - Install Lever trim

  6. Screw inside lever into position and tighten lever collar with a supplied spanner wrench.
    SDC Z7880 Mortise Lock - Install Lever trim 6

F. Install Cylinder and Armor Face Plate

  1. Screw Mortise Cylinder into the threaded hole of the lock case.
  2. Tighten the Set Screw against cylinder(s) by turning clockwise as shown.
  3. Install Face Plate onto lock case front and fasten with supplied screws.

SDC Z7880 Mortise Lock - Install Cylinder and Armor Face
Plate

E. Install for 07 lever trim

  1. Place the spring, collar, and then reversible spring cage onto the outside lever assembly with arrows pointing in direction of lever rotation. Insert the spindle into a hub of the lock case.
  2. Install outside lever assembly with mounting posts through door and position lever assembly onto the spindle.
  3. Install inside spring cage onto the spindle with the arrows pointing in the direction of inside lever rotation.
  4. Install inside mounting plate over the spindle and onto the mounting posts of outside assembly. Tighten with provided screws.
  5. Cap inside rose over the mounting plate and insert second spring.
  6. Screw inside lever into position and tighten lever collar with the supplied spanner wrench.

SDC Z7880 Mortise Lock - Install for 07 lever trim

F. Install Cylinder and Armor Face Plate

  1. Screw Mortise Cylinder into the threaded hole of the lock case.
  2. Tighten the Set Screw against cylinder(s) by turning clockwise as shown.
  3. Install Face Plate onto the lock case and fasten with the supplied screw.

SDC Z7880 Mortise Lock - Install Cylinder and Armor Face
Plate

INSTALLATION WIRE DIAGRAM
Model 7870/72 & 7880/82 Series
STANDARD WIRING
12 or 24VDC (Locks are voltage specific)
12VDC@.6AMP; 24VDC@.3AMP

SDC Z7880 Mortise Lock - STANDARD WIRING

Z7880 (Failsafe) Lock Power (12VDC)
Access control does not engage the outside lever when the deadbolt is thrown. *Install MOV across the coil to protect ACS electronics, as close as possible to the lock

SDC Z7880 Mortise Lock - Lock Power

Z7880 (Failsafe) Lock Power (24VDC )
Access control does not engage the outside lever when the deadbolt is thrown. *Install MOV across the coil to protect ACS electronics, as close as possible to the lock

Optional Monitoring Outputs

SDC Z7880 Mortise Lock - Optional Monitoring Outputs

Z7882 (Failsecure) Lock Power (12VDC)
Access control does not engage the outside lever when the deadbolt is thrown. *Install MOV across the coil to protect ACS electronics, as close as possible to the lock

SDC Z7880 Mortise Lock - Z7872 STANDARD WIRING

Z7882 (Failsecure) Lock Power (24VDC)
Access control does not engage the outside lever when the deadbolt is thrown. *Install MOV across the coil to protect ACS electronics, as close as possible to the lock

SDC Z7880 Mortise Lock - Z7872 STANDARD WIRING

Z7870 (Failsafe) Lock Power (12VDC)
Access control always engages outside the lever. *Install MOV across the coil to protect ACS electronics, as close as possible to the lock

SDC Z7880 Mortise Lock - Z7870 Install Lockcase

Z7870 (Failsafe) Lock Power (24VDC)
Access control always engages outside the lever. *Install MOV across the coil to protect ACS electronics, as close as possible to the lock

SDC Z7880 Mortise Lock - Z7870 nstall Lockcase

Z7872 (Failsecure) Lock Power (12VDC)
Access control always engages outside the lever. *Install MOV across the coil to protect ACS electronics, as close as possible to the lock

SDC Z7880 Mortise Lock - Z7882 Strike Installation

Z7872 (Failsecure) Lock Power (24VDC)
Access control always engages outside the lever. *Install MOV across the coil to protect ACS electronics, as close as possible to the lock

SDC Z7880 Mortise Lock - Z7882 Strike Installation

INSTALLATION WIRE DIAGRAM

Models with optional connectors

SDC Z7880 Mortise Lock - INSTALLATION WIRE DIAGRAM

P:\INST INSTRUCTIONS\ELECTRIFIED LOCKSETS\INST-Z7800_70_72_80_82 REV E 09-21
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
[t] 800.413.8783 ■ 805.494.0622 ■ E-mail: service@sdcsecurity.com ■ 801 Avenida Acaso, Camarillo, CA 93012 ■ PO Box 3670, Camarillo, CA 93011

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals