StarTech IES1G52UP12V 5 Port Unmanaged Industrial-Grade Switch User Guide
- June 6, 2024
- StarTech
Table of Contents
Quick-Start Guide
5 Port Unmanaged Industrial-Grade Switch + 2 Open SFP – 12V
Product Diagram (IES1G52UP12V)
Component | Function |
---|---|
1 | Power LED Indicators |
• Terminal P2 (middle), Terminal P1 (bottom)
• On – P1/2 is connected
• Off – P1/2 is not connected
2| ERR Alarm Relay LED
Indicator| • Color – Amber
• On – Only P1 or P2 is connected
• Off – Both P1 and P2 are connected
3| F5/6 Port LED
Indicators| • Color – Green
• F5 (top), F6 (bottom)
• On – SFP link/connection is detected
• Off – SFP link/connection is not detected
• Flashing – SFP is active
4| SFP Slots F6 (Left) and
F5 (Right)| • Supports 100/1000Base-X SFP Transceiver Modules
5| DIP Switches| • Enable SFP Slot F5 or T5 Network Port
• Change the speed settings
6| Port Status LED
Indicators| • Color – Green
• On – Connection is detected
• Flashing – Data is transmitting/receiving
7| LNK and SPD LED
Indicators| • Indicates the link status and speed
LNK(Green)
• On – Network connection detected
• Flashing – Data is transmitting/receiving
SPD (Amber)
• On – 1000 Mbps network speed
• Off – 10/100 Mbps network speed
8| Non-PoE Port| • Provide an Ethernet Connection to one Network
Device
• Connect using a Fiber or Copper Network Cable
9| PoE Ports| • Connect any Network Device to provide an Ethernet
Connection to up to 4 Network Devices
• Provide a PoE Connection to 4 Devices
• Maximum PoE power budget is 30W per port up to a total overall power budget
of 120W
10| Terminal Block Power
Input Port| • Provides power to the Switch
• Supported power input voltage range is 12-56V
11| Grounding Screw| • Attach a Grounding Wire to protect Network
Equipment
Requirements
For the latest requirements, please visit www.startech.com/IES1G52UP12V.
- DC Power Supply x (up to) 2
- PoE Powered Device x (up to) 4
- RJ45 Terminated UTP/STP Cat 5e (or better) Network Cable x (up to) 5
- MSA-Compliant 100/1000Base-X SFP Transceiver Module x (up to) 2
- Fiber Cable x (up to) 2
- Earth Ground Connection x 1
- Grounding Wire x 1
- (Optional – for power) Flat Head Screwdriver x 1
- (Optional – for mounting) #2 Phillips Head Screwdriver x 1
- (Optional – for mounting) Screws for Wall Mounting x 2
Installation
Grounding the Switch
Connect a Grounding Wire to the Grounding Point on the Switch and to the
Earth Ground Connection.
Connect the Power Sources
Terminal Block
Connecting and installing the Terminal Block must be completed by a licensed
Electrician.
Notes: Make sure that you turn off the power source before connecting the
power wire to the Terminal Block.
Do not exceed the recommend voltage as it may result in personal or product
damage.
This unit includes an additional 24V@1A Relay Circuit (ALM). When two Terminal
Power Sources are connected the Relay stays in Open Mode. If only one Power
Source is connects the Relay switches to Short Mode.
-
Connect the Power Wires from a DC Power Source (12 – 56V DC) or the provided Barrel Power Connector Adapter to the Terminal Block Connectors on the Switch. The terminals are marked on the exterior of the Switch (connect the Positive Wire to V+ and the Negative Wire to V-).
• Secure the Wires by tightening the Screws in the Terminal Block with a Flat Head Screwdriver -
(Optional) Repeat step 1 to add a redundant Power Source.
Select the Default Function and Speed using the DIP Switches
Toggle the DIP Switches up and/or down to select the SFP Slot F5 (Right) or T5
Network Port. When SFP Slot F5 has been selected, the T5 Network Port will be
completely disabled. When the T5 Network Port has been selected, SFP Slot F5
will be completely disabled. The DIP Switches can also be used to select the
Network Speed.
Note: If DIP 1 is set to T5 then DIP 2 must be set to 1000M.
Connecting the Switch
DIP Switch Set to F5
- Insert two MSA-Compliant SFP Transceiver Modules (sold separately) into the SFP Slots F5 and F6 on the Switch.
- Connect a Fiber Optic Cable (sold separately) to the Fiber Optic Ports on each of the SFP Modules and to the Fiber-Network Devices.
DIP Switch Set to T5
Connect a Network Cable to the Network Device and to the T5 PoE Port/any PoE Port on the Switch.
FCC Compliance Statement
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Changes or modifications not expressly approved by StarTech.com could void the
user’s authority to operate the equipment.
Industry Canada Statement
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe [A] est conforme à la norme NMB-003 du
Canada.
CAN ICES-3 (A)/NMB-3(A)
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions:
(1) This device may not cause interference, and (2) This device must accept
any interference, including interference that may cause undesired operation of
the device.
Use of Trademarks, Registered Trademarks, and other Protected Names and
Symbols
This manual may make reference to trademarks, registered trademarks, and other
protected names and/or symbols of thirdparty companies not related in any way
to StarTech.com. Where they occur these references are for illustrative
purposes only and do not represent an endorsement of a product or service by
StarTech.com, or an endorsement of the product(s) to which this manual applies
by the third-party company in question. StarTech.com hereby acknowledges that
all trademarks, registered trademarks, service marks, and other protected
names and/or symbols contained in this manual and related documents are the
property of their respective holders. PHILLIPS® is a registered trademark of
Phillips Screw Company in the United States or other countries.
Warranty Information
This product is backed by a two-year warranty.
For further information on product warranty terms and conditions, please refer
to www.startech.com/warranty.
Limitation of Liability
In no event shall the liability of StarTech.com Ltd. and StarTech.com USA LLP (or their officers, directors, employees or agents) for any damages (whether direct or indirect, special, punitive, incidental, consequential, or otherwise), loss of profits, loss of business, or any pecuniary loss, arising out of or related to the use of the product exceed the actual price paid for the product. Some states do not allow the exclusion or limitation of incidental or consequential damages. If such laws apply, the limitations or exclusions contained in this statement may not apply to you.
Safety Measures
• If product has an exposed circuit board, do not touch the product under
power.
StarTech.com Ltd.
45 Artisans Cres
London, Ontario
N5V 5E9
Canada| StarTech.com LLP
2500 Creekside
Parkwy
Lockbourne, Ohio
43137
U.S.A.| StarTech.com Ltd.
Unit B, Pinnacle 15
Gowerton Rd,
Brackmills
Northampton
NN4 7BW
United Kingdom| FR: startech.com/fr
DE: startech.com/de
ES: startech.com/es
NL: startech.com/nl
IT: startech.com/it
JP: startech.com/jp
---|---|---|---
To view manuals, FAQs, videos, drivers, downloads, technical drawings, and more, visit www.startech.com/support.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>