DEMA I1305 Fusion One Housekeeping Chemical Dispensing System
Installation and Setup Guide
Fusion One accurately blends proportioned chemical with water for cleaning, sanitizing or `needs. The dispensing system uses a pilot drive water valve designed for easy maintenance. Fusion One is engineered with 1055 approved back flow protect using DEMA’s Air Gap or Action Gap proportioning system.
Warnings
All installations must conform to local plumbing codes and use approved
backflow prevention devices. A pressure indicating tee is to be installed with
existing faucets according to local plumbing codes in the state of Wisconsin
and any other state that requires the use of a pressure indicating tee.
ALWAYS WEAR PROTECTIVE CLOTHING AND EYEWEAR WHEN WORKING WITH CHEMICAL
PRODUCTS.
Installation and Servicing
WARNING : INSTALLATION OF DEMA PRODUCTS MUST MEET ALL APPLICABLE PLUMBING CODES AND REGULATIONS ESTABLISHED BY NATIONAL, CITY, COUNTY, PARISH, PROVINCIAL OR OTHER AGENCIES. IT IS POSSIBLE THAT PLUMBING CODES AND REGULATIONS REQUIRE THAT A CERTIFIED INSTALLATION CONTRACTOR OR ENGINEER PERFORM THE PLUMBING INSTALLATION.
-
Locate where to install the Fusion One dispenser. Keep the following in mind
- Mount near or over a mop sink.
- Best access to water hookup.
-
Remove the Fusion One cover by pressing the plastic tabs on the side of the unit and swing the bottom away from the mounting bracket.
-
Determine if the water supply connection should be on the right of left-hand side of the dispenser.
- The entire valve and proportioner assembly can be removed from the mounting bracket (see illustration on this page).
- The water supply connection can be moved to either side by removing the plastic, orange retainer clips, the plug and the water connection fitting. Then replace the retainer clips.
-
Locate the 2 key shaped mounting holes in the back plate. Mount the Fusion One using the 2 mounting screws and anchors that are included in the installation kit; with the aid of the integrated bubble level.
-
Install the desired metering tip by threading tip into the proportioner chemical pick-up elbow.
-
Cut the chemical supply tube to the length allows the foot valve to rest on the bottom of the chemical container. Slide the ceramic weight onto the chemical supply tube until it is against the foot valve. This will keep the foot valve at the bottom of the chemical container.
- Note: Chemical containers cannot be greater than 6 feet (1.8M) below the Fusion One dispenser.
-
Install the Fusion One cover by positioning the top of the cover near the top of dispenser back plate and push the cover back over the valve assembly until the tab latches on side of the unit.
-
Connect the water line to the inlet of the Fusion One.
-
Note: The water pressure must be between 20psi and 95psi. Optimum chemical induction occurs between 30psi – 60psi.
-
The water inlet options for the Fusion One are:
i. Garden Hose (female)
ii. 3/8” Brass Compression Fitting (suitable for 3/8” OD soft copper water line)
iii. 3/8” John Guest Push-on Water Fitting (suitable for 3/8” OD soft copper or LDPE tubing)
iv. 3/8” Brass Barb Water Fitting (suitable for 3/8” LDPE tubing) -
The Fusion One can be used in conjunction with a pressure indicating tee, P/N 68.6.QD2.
-
-
Removal of Button Tab to engage Locking Activation feature (for 4GPM Proportioners).
Step 1: Remove Fusion One cover (see #2 above).
Step 2: Break off tab with pliers.
Fusion Cover – Rear View
Metering Tip Kits
Table 1: Fusion Metering Tips 100.15K (Provided)
Metering Tip Color
| 1 GPM Air Gap Proportioner| 4 GPM Air Gap Proportioner
Oz./gal| ml/L| Ratio : 1| Oz./gal| ml/L| Ratio :
1
Tan| 1.37| 10.57| 93.65| 0.37| 2.91| 343.19
Orange| 1.67| 12.91| 76.48| 0.44| 3.45| 289.14
Turquoise| 1.74| 13.44| 73.43| 0.49| 3.83| 260.27
Pink| 3.45| 26.28| 37.06| 0.92| 7.12| 139.38
Light Blue| 4.47| 33.73| 28.65| 1.10| 8.49| 116.74
Brown| 5.04| 37.87| 25.41| 1.40| 10.80| 91.62
Red| 6.89| 51.08| 18.58| 1.78| 13.70| 72.01
White| 7.43| 54.87| 17.23| 1.90| 14.60| 67.48
Green| 7.46| 55.06| 17.16| 1.98| 15.26| 64.53
Blue| 9.14| 66.63| 14.01| 2.54| 19.44| 50.45
Yellow| 14.07| 99.07| 9.09| 4.29| 32.46| 29.81
Black| 17.36| 119.45| 7.37| 4.53| 34.19| 28.25
Purple| 31.36| 196.81| 4.08| 7.67| 56.53| 16.69
Gray| 34.95| 214.51| 3.66| 8.77| 64.15| 14.59
No Tip| 35.95| 219.31| 3.56| 10.54| 76.05| 12.15
Table 2: Ultra Lean Metering Tips 100.15KU (Not Provided)
Metering Tip Color
| 1 GPM Air Gap Proportioner| 4 GPM Air Gap Proportioner
Oz./gal| ml/L| Ratio : 1| Oz./gal| ml/L| Ratio :
1
Copper| 0.47| 3.70| 269.58| 0.14| 1.10| 904.85
Pumpkin| 0.75| 5.80| 171.35| 0.22| 1.71| 585.42
Burgundy| 0.87| 6.75| 147.10| 0.25| 1.98| 503.37
Lime Green| 1.07| 8.26| 120.14| 0.31| 2.44| 408.69
Table 3: Fusion Metering Tips 100.15K (Provided)
Metering Tip Color
| 1 GPM Action Gap Proportioner| 4 GPM Action Gap Proportioner
Oz./gal| ml/L| Ratio : 1| Oz./gal| ml/L| Ratio :
1
Tan| 0.96| 7.46| 133.12| 0.32| 2.49| 399.99
Orange| 1.20| 9.30| 106.51| 0.38| 2.97| 335.84
Turquoise| 1.43| 11.01| 89.81| 0.45| 3.50| 285.06
Pink| 2.26| 17.36| 56.62| 0.79| 6.15| 161.72
Light Blue| 2.87| 21.95| 44.56| 1.01| 7.81| 127.09
Brown| 3.40| 25.86| 37.68| 1.20| 9.30| 106.48
Red| 4.10| 31.08| 31.18| 1.42| 10.99| 89.99
White| 4.67| 35.18| 27.43| 1.67| 12.86| 76.79
Green| 4.85| 36.54| 26.38| 1.79| 13.81| 71.40
Blue| 6.96| 51.58| 18.39| 2.46| 18.83| 52.10
Yellow| 10.27| 74.31| 12.46| 3.79| 28.79| 33.74
Black| 12.90| 91.59| 9.92| 4.86| 36.59| 26.34
Purple| 26.69| 172.54| 4.80| 11.31| 81.19| 11.32
Gray| 30.36| 191.72| 4.22| 13.76| 97.10| 9.30
No Tip| 45.48| 262.17| 2.81| 24.77| 162.15| 5.17
Table 4: Ultra Lean Metering Tips 100.15KU (Not Provided)
Metering Tip Color
| 1 GPM Action Gap Proportioner| 4 GPM Action Gap Proportioner
Oz./gal| ml/L| Ratio : 1| Oz./gal| ml/L| Ratio :
1
Copper| 0.34| 2.67| 373.60| 0.12| 0.94| 1060.18
Pumpkin| 0.56| 4.33| 230.23| 0.19| 1.50| 665.14
Burgundy| 0.77| 6.00| 165.66| 0.24| 1.85| 539.29
Lime Green| 0.84| 6.52| 152.39| 0.28| 2.21| 451.24
Replacement Parts: Fusion Unit
FUSION REPLACEMENT PARTS
Item No.| DEMA Part No.| QTY| DESCRIPTION
1| 40.826.1| 1| BASE, FUSION HK
2| 40.970.1| 1| FUSION BUBBLE LEVEL
3| 44.116.3| 3| #8 HI-LO SCREW X 1″ LONG
4| 40.847.2| 1| FUSION VALVE ASSEMBLY (SEE PG. #7 FOR PARTS)
5| 63.78| 4| O-RING-SEAL EPT (7/16″I.D. X 3/8″O.D. X 1/16″ NOM.)
6| 40.853.1| 1| END PLUG PILOT ACTIVATED VALVE
7| 40.854.1| 2| RETAINING CLIP PILOT ACTIVATED VALVE
8| 40.931.1| 1| BOTTOM LEVER, FUSION HK
9| 40292.1| 1| EXTENSION SPRING
10| 40.929.1| 1| BUTTON, FUSION HK
11| 41.185.1| 1| FRONT COVER, FUSION, W/LABELS
12| 40.930.1| 1| RETENTION LATCH
13| 81.20.2| 2| #4 X 3/8″ HI LO SCREW
14| 61.22.3| 1| ACTION GAP PROPORTIONER ASSEMBLY (4GPM)
15| 16.30| 1| ACTION GAP
16| 65.10.2| 1| STANDARD COUPLING, GARDEN HOSE THREAD
16| 98.55.1| 1| EURO COUPLING, BRITISH HOSE THREAD
17| 40.852.1| 1| WATER INLET FITTING, PILOT ACTIVITED VALVE
18| 100.38| 1| STRAINER WASHER
19| 61.22.3BAG| 1| AIR GAP PROPORTIONER ASSEMBLY (4GPM)
20| 40.925.1| 1| FUSION VALVE INLET ADAPTER W/GHT, ASSEMBLY
20| 40.925.2| 1| FUSION VALVE INLET ADAPTER W/BRITISH PSPP,
ASSEMBLY
20| 40.925.3| 1| FUSION VALVE INLET ADAPTER W/GHT, ASSEMBLY,
PLASTIC
20| 40.925.4| 1| FUSION VALVE INLET ADAPTER W/BSPP, ASSEMBLY,
PLASTIC
21| 40.926.1| 1| FUSION VALVE PLUG ADAPTER, ASSEMBLY
22| 77.2.1.06| 1| FLOW DISC, PINK, [1.06(GPM) / 4(L/MIN)]
Not Installed W/Air Gap Models
22| 77.6.2.64| 1| FLOW DISC, YELLOW, [2.64(GPM) / 10(L/MIN)]
22| 40.570.1| 1| FLOW DISC, NATURAL, [4.45(GPM) / 16.85(L/MIN)]
23| 89.18.1| 1| RETAINER, FLOW DISC
24| 41.186.1| –| FUSION VALVE CONNECTOR
25| 89.30.GAP| 1| HOSE HANGER ASSY. FOR GAP MODELS ONLY
Replacement Parts Valve Body
VALVE REPLACEMENT PARTS
Item No.| DEMA Part No.| QTY| DESCRIPTION
1| 40.854.1| 2| RETAINING CLIP PILOT ACTIVATED VALVE
2| 41.058.1| 1| DIAPHRAGM CAP
3| 619.21| 1| O-RING SEAL EPDM (15/16” X 1/16”)
4| 98.26.1| 1| 1-1/16″ DIAPHRAGM
5| 40.824.1| 1| VALVE BODY
6| 40.849.1| 1| BUTTON, PILOT ACTIVATED VALVE
7| 640.106| 2| O-RING SEAL (3/16″ID X 3/8″OD X 3/32″NOM.)
8| 98.39.2| 1| RETURN SPRING
9| 63.78| 1| O-RING-SEAL EPT (7/16″I.D. X 9/16″O.D. X 1/16
NOM.)
10| 40.851.1| 1| BOTTOM CAP
11| 40.925.1| 1| FUSION INLET ADAPTER W/GHT
11| 40.925.2| 1| FUSION INLET ADAPTER W/BSPP
11| 40.925.3| 1| FUSION INLET ADAPTER W/GHT, PLASTIC
11| 40.925.4| 1| FUSION INLET ADAPTER W/BSPP, PLASTIC
12| 40.927.1| 1| 3/8” ELBOW COMPRESSION INLET FITTING
13| 40.927.2| 1| 3/8” STRAIGHT COMPRESSION INLET FITTING
14| 40.927.3| 1| 3/8” JOHN GUEST PUSH-ON INLET FITTING
15| 40.927.4| 1| 3/8” ELBOW JOHN GUEST PUSH-ON INLET
FITTING
16| 40.927.5| 1| 3/8” BARB INLET FITTING
Product Dimensions
Specifications
- Operation Pressure Rating: 20psi – 95psi
- Safety Pressure Rating: 125psi
- Water Temperature Rating: 45ºF (7ºC) – 125ºF (50ºC) Max
- Back Flow Protection – ASSE 1055 (Action Gap & Air Gap)
- ASME A112.1.2 (Air Gap)
Warranty
Merchandise Returns
No Merchandise Will Be Returned For Credit Without DEMA’S Written Permission. Returned Merchandise Authorization Number Is Required In Advance Of Return.
Product Warranty
DEMA products are warranted against defective material and workmanship under normal use and service for one year from the date of manufacture. This limited warranty does not apply to any products that have a normal life shorter than one year or failure and damage caused by chemicals, corrosion, physical abuse, or misapplication. Rubber and synthetic rubber parts such as “o”-rings, diaphragms, PVC tubing, and gaskets are considered expendable and are not covered under warranty. This warranty is extended only to the original buyer of DEMA products. If products are altered or repaired without prior approval DEMA, this warranty is void.
Defective units or parts should be returned to the factory with transportation prepaid. If inspection shows them to be defective, they will be repaired or replaced without charge, F.O.B. factory. DEMA assumes no liability for damages. Return merchandise authorization number must be granted in advance of return units for repair or replacement (See “Merchandise Returns” above).
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>