DEMA 5801V.BV Manual Solid Bowl Feeder Instruction Manual
- May 15, 2024
- DEMA
Table of Contents
DEMA 5801V.BV Manual Solid Bowl Feeder
Overview
The DEMA® Manual Solid Bowl Feeder is for use with a solid product being put into a reservoir. The Bowl features a bypass line to allow the proper dilution of product from the bowl to put into the three compartment sink or another container. It is operated by the ball valve on the inlet which controls the flow to the product and the bypass line.
Warnings
All installations must conform to local plumbing codes and use approved backflow prevention devices. A pressure indicating tee is to be installed with existing faucets according to local plumbing codes in the state of Wisconsin and any other state that requires the use of a pressure indicating tee.
ALWAYS WEAR PROTECTIVE CLOTHING AND EYEWEAR WHEN WORKING WITH CHEMICAL PRODUCTS.
Specifications
Operational Requirements
- Max./Min. Pressure 80 PSI, 30 PSI
- Max./Min. Temperature 160 DEG F, 110 DEG F
Water temperature should be kept between 120°F – 140°F. [Water
Temperature should NEVER exceed 160°F]
Overall Size
Installation & Operation
Wall Mounting
- Use mounting holes to pick mounting position on wall.
- Mount the bowl on the wall using mounting hardware.
Connection to Water Supply
- Attach hose from water supply to inlet side of the ball valve.
Chemical Dilution Adjustment
Chemical dilution can be adjusted using a metering screw located just above the bowl. Turning the screw clockwise decreases the amount of chemical and turning it counterclockwise increases the amount. Turn the screw clockwise until it stops to use the chart below and the number of turns from closed to determine the amount of product needed. No noticeable adjustment will occur past four turns out. Seven full turns out will completely loosen the screw. The chart below is for reference only. Test and adjust as required.
| Bypass @ 20 PSI| Bypass @ 30 PSI| Bypass @ 40 PSI| Bypass @ 50 PSI
---|---|---|---|---
Approx. bypass water at all settings| .99 GPM| 1.27 GPM| 1.48 GPM| 1.71 GPM
of Turns from Closed| Oz/min @ 20 PSI| Oz/min @ 30 PSI| Oz/min @ 40 PSI|
Oz/min @ 50 PSI
---|---|---|---|---
1 turn| 7.1| 9.1| 11.4| 12.4
2 turns| 19.6| 24.7| 28.9| 32.5
3 turns| 44.4| 56.3| 66.6| 74.1
4 turns| 62.9| 77.4| 91.6| 103.9
Note: The numbers listed are only the water that passes through the spray
arm.
This does not include the bypass water. ****
Troubleshooting
Symptom | Probable Cause | Remedy |
---|
Too much product is getting into the container/Too little product is getting
into the container.| 1. Set screw not set properly.| 1. Check to
make sure the set screw is in the unit and is tightened down properly using
the table above.
2. Bypass clogged or not working.| 2. Look at the tubing to see if
any clogs appear, watch the outlet tubing to be sure water is coming out of
it. Remove clog if found.
PARTS
5 801 SERIES VIKING BOWL PARTS LIST – MANUAL BOWL
ITEM NO.| DEMA NO.| DESCRIPTION
1| 41778-1| BOWL BODY
2| 81-18-1| #6 x 3/8′ HI-LO SCREW, SS [QTY. 5]
3| 100-24| METERING SCREW W/ O-RING
4
| 58-2C| VACUUM BREAKER [JACO]
58-2B| VACUUM BREAKER [METAL]
58-2| VACUUM BREAKER [JG]
5| 41774-1| VACUUM BREAKER BRACKET WELDMENT
6| 16-11| BALL VALVE ¼” NPT-FEMALE X FEMALE
7| 65-10-2| COUPLING, NICKEL PLATED
8| 65-17-3| G.H. SWIVEL ADAPTER 1/4 NPT PLATED
9| 100-38| STRAINER WASHER
10| 44-116-1| #8 HI-LO SCREW X ½” LONG [QTY. 2]
11| 41781-1| BOWL DIVERTER VALVE
12| 33-34| COMPRESSION NUT [QTY. 2]
13| 40-980-1| TUBE SUPPORT FOR ¼” O.D. PLASTIC COMP. TUBE FITTING [QTY. 2]
14| 33-32| COMPRESSION SLEEVE [QTY. 2]
15| 64-13-1| ¼” TUBING, PVC, 15” LONG [QTY. 2]
16| 41782-1| BOWL TUBING CLAMP [QTY. 2]
17| 41780-1| BOWL DIVERTER ARM
18| 41789-1| TORSION SPRING
19| 58-311| STANDARD NOZZLE [POWDER & SOLID]
58-315| POWDER NOZZLE [POWDER ONLY]
58-316| CONE NOZZLE [POWDER & SOLID]
58-317| NBD NOZZLE [FOR LOW PRESSURE]
20| 41779-1| SPRAY ARM
21| 58-324| COMPLETE SPRAY ARM ASSEMBLY KIT
22| 58-7-5| 5′ LENGTH OF 5/8″ ID X 7/8″ OD TUBING [OUTLET]
23| 58-318| ELBOW [BULKHEAD] FITTING COMPLETE
24| 58-319| STANDARD HARDWARE BAG
Warranty
Merchandise Returns
No Merchandise will be Returned for Credit Without DEMA’S Written
Permission.
Returned Merchandise Authorization Number is Required in Advance of
Return.
Product Warranty
DEMA® products are warranted against defective material and workmanship under normal use and service for one year from the date of manufacture. This limited warranty does not apply to any products that have a normal life shorter than one year or failure and damage caused by chemicals, corrosion, physical abuse, or misapplication. Rubber and synthetic rubber parts such as “O”-rings, diaphragms, PVC tubing, and gaskets are considered expendable and are not covered under warranty. This warranty is extended only to the original buyer of DEMA products. If products are altered or repaired without prior approval of DEMA, this warranty is void.
Defective units or parts should be returned to the factory with transportation prepaid. If inspection shows them to be defective, they will be repaired or replaced without charge, F.O.B. factory. DEMA assumes no liability for damages. Return merchandise authorization number must be granted in advance of returned units for repair or replacement (See “Merchandise Returns” above).
Read User Manual Online (PDF format)