OVERVIEW
The AEOTEC Door/Window Sensor 7 Pro is a sensor, which detects if your window is opened, closed, or tilted. The sensor is easily retrofittable. Furthermore, the AEOTEC Door/Window Sensor can include other sensors by being connected with other binary sensors like NTC contacts, microswitches, or flood sensors. Thanks to its slim design the AEOTEC Door/Window Sensor 7 Pro can be installed unflashy on every window. The sensor just has to be installed on the window casement. Additionally, there has to be a slim magnet installed closely to the sensor at the window frame. By using a patented method the sensor can reliably detect the exact position of the window. With the potential free input, the Door/Window Sensor can also include other sensors in your Z-Wave system. For that, the binary sensor is connected to the potential free input of the sensor. Besides sensors, there can also be connected momentary switches, which control scenes in your gateway. Tripple clicking the tamper button includes (adds) and excludes (removes) the device. A single click on the button will wake up the device. The device supports the Z-Wave Security S2 framework with authenticated and unauthenticated network keys. Please follow the instructions on the central controller when including. The device also supports SmartStart.
Terminology | Description |
---|---|
tamper switch | Used for networking, resetting, and protecting the device. |
Led (Green, Red) | Used for indicating the current state of the product. |
Magnet | Change the sensor state via making the Magnet away or near from Main |
Sensor.
Screw Terminal| Used for the interconnection of external binary sensors as
well as actuators and dry-contacts.
SPECIFICATIONS
Structural
Parameter | Value |
---|---|
Product Identifier | ZW012 |
Dimensions | 28x95x35mm |
Weight | Main Sensor: 20g Magnet Sensor: 3g |
Color | White |
Usage | For indoor use. |
Operating Temperature | 32~104°F (0~40°C) |
Relative Humidity | 8%~80% |
Hardware
Buttons and Connectors | Tamper Button (x1), Magnet(x2) |
---|---|
Input Voltage | 3.0V Lithium battery |
Battery Type | 1*1/2AA |
Battery Included | Yes. 1pcs battery included. |
Battery Required | Yes. 1pcs battery required. |
Battery Info | Model: ER14250 1/2AA |
Capacity: 1200mAh
Detachable: Yes
Chargeable: No
Endurance: 2 years
Working Current| 30mA
Standby Current| 5uA
Maximum Standby
Power Consumption| 0.03mW
Maximum transmission| 5mW
Built-in Sensors| hall switch
Software
Parameter | Value |
---|---|
Wireless Technology | Z-Wave |
Certification Type | Z-Wave Plus v2 Certification |
Z-Wave SDK Version | 7.15.2 |
Z-Wave Library Type | Enhanced 232 Slave |
Z-Wave Role Type | Reporting Sleeping Slave[0x06] |
Generic Product Type | GENERIC_TYPE_SENSOR_NOTIFICATION [0x07] |
Specific Product Type | SPECIFIC_TYPE_NOTIFICATION_SENSOR [0x01] |
Security Class | Non-Security, S2 Unauthenticated, and S2 Authenticated |
SmartStart Compatible | Support. After powering on, SmartStart is auto |
activated.
Over The Air (OTA)| Support. Firmware can be updated via RF.
Multi-Channel Product| No
Association| Support. Refer to Section 4.7 Association Group Info.
Factory Reset| Support. Refer to Section 3.7 How to factory reset.
Power-down Memory| Support. All command settings will stay unchanged even
power is down.
Sensor State Report| Support. Send out a notification via Group 1 when Magnet
is away or near.
Control other product| Support. Control other Z-Wave products directly via
Group 2 when Magnet is away or near
QUICK START
Important safety information
Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Optimally placing the product
This is a secure Alarm Sensor. To run this device please insert fresh *1
1/2 AA** batteries. Please make sure the internal battery is fully charged.
The DSK for the S2 inclusion can be found inside the packaging of the sensor.
If your Z-Wave gateway supports SmartStart: scan the QR code on Door / Window
Sensor 7 Pro using the gateway’s app. Your sensor will join your Z-Wave
network automatically.
How to install the product
The sensor can be mounted either on the moving part or on the fixed part of a door or a window. Mounting can be accomplished either using the tape by peeling off the protection foil or using two screws with holes inside the battery compartment. If the tilt detection on a window (only normal windows, no roof windows) shall be used the sensor device must be placed on the moving part of the window and the magnet on the window frame.
The sensor comes with two types of magnets:
- The standard magnet is covered by a plastic part, mountable beside the sensor. Make sure the two indicating lines on the sensor enclosure and magnet are opposite to each other. The image on the righthand side shows the position of the magnet and sensor body.
- A slim naked magnet to be mounted behind the sensor in case the sensor body is placed on the side of a window.
- To use the tilting function, the opening angle of the window must be at least 5°.
| For German-style windows where the window sits on top of the window frame mounting on the side of the window is highly recommended. If no tilting detection is used, the sensor can be placed on any position of the door or the window. In case tilting detection is desired the sensor should be placed on the upper side of the window.|
---|---|---
How to add the product
The following will step you through by adding the product to your Z-Wave network.
- Open the housing.
- Remove the battery protection.
- Press the tamper on the side of the appliance three times quickly.
If your Z-Wave gateway supports SmartStart: scan the QR code on Door / Window Sensor 7 Pro using the gateway’s app. Your sensor will join your Z-Wave network automatically.
How to remove the product
- Open the housing.
- Press the tamper on the side of the appliance three times quickly.
How to manually trigger Wake Up
- A single click on the button will wake up the device.
- Repower on will wake up the device.
Note:
The Wake Up period starts when the node issues a Wake-Up Notification and it
ends either 10 seconds after the last received/transmitted frame or at the
reception of a Wake Up No More Information Command by the Wake-Up destination.
How to factory reset
This device also allows being reset without any involvement of a Z-Wave
controller. This procedure should only be used when the primary controller is
inoperable.
Once the Cover is removed and the tamper switch is tripped, push the tamper
for 5 seconds until the RED LED blinks once. Then release the tamper and use
it again for 5 seconds while the RED LED is blinking until the GREEN LED
blinks once.
Safety Warning for Batteries
The product contains batteries. Please remove the batteries when the device is not used. Do not mix batteries of different charging levels or different brands.
Product Usage
Once installed the sensor will report “open” and “close” status changes to a central Z-Wave controller using notification commands. Additionally, the sensor can directly control other devices using association group 2. Using configuration commands the source of “open” and “close” events can be chosen between the internal magnet detector or external dry contact connected via the screw terminal. The device is protected by a tamper switch.
Tilt detection
The tilt detection allows reporting the way a window is opened. This is
accomplished using the command class “binary sensor – tilt-type”. The tilt
function has 3 modes (mode 1 by default):
Mode 0: turn off the tilt function
Mode 1: Enable tilt function. It needs to be used with magnets. In case
the magnet is far away and the tilt angle of the product is greater than 5
degrees, the tilt event is triggered. In case the magnet is near, the tilt
event is released.
Mode 2: Enable tilt function. It can be used alone, but need to identify
the current installation location. When this mode is configured or powered on
(mode 2), it will enter the identification mode and the green light will
flash. The product needs to stand still for 3-8 seconds. If the recognition
fails, the red light will be on, and the tilt function is not available. It
needs to be recognized again. If the recognition is successful, the green
light will be on. In case the tilt angle of the product is greater than 5
degrees, the tilt event is triggered. In case the tilt angle of the product is
less than 5 degrees, the tilt event is released
Screw Terminal
The product must support the interconnection of external binary sensors as
well as actuators and dry contacts. The product allows interconnection
with external sensors/actuators via 3-pin screw terminals with the following
pinout:
-
1: Ground
-
2: Digital Input
-
3: VCC (direct battery supply)
VCC + Ground terminals can be used to externally power the sensor with a 3.6V battery or special power adapter (which is not included in the scope of delivery). Digital + VCC is used to connect the external dry contact.
Link testing
When activated by configuration parameter #5 the device can perform a link
test with device No.1. Double-clicking the tamper will start the process. As a
result, the GREEN LED will blink two times in case of success and the RED LED
will blink two times in case of failure.
SOFTWARE FUNCTION DEFINITION
User Behavior Interaction
User behavior | Out of the Z-Wave network | In the Z-Wave network |
---|---|---|
Power OFF | cut the power. | Cut the power. |
Power ON | Send Inclusion Requests for SmartStart Learn Mode. |
LED will flash red 5 times, which means it’s out of the Z-Wave network. if the
gateway is adding the device succeeds through SmartStart, LEO will light up
green for 2 seconds If Adding fails, LEO will off. The device will auto-reset
and then activate SmartStart Learn Mode again.| Send Wake Up
Notification.
LED will become flash green once, and device will wake up for 15 seconds.
Make Magnet away or near| LED will flash red once.| Trigger Association
function.
Refer to Section 4.7 and 4.34 for details about the Association function.
LED will flash red once.
Click tamper switch once| 1. LED will flash green once.
LED will flash green one.
2. Exit Classic Inclusion Learn Mode:
If the tamper switch is clicked again during the Classic inclusion Learn Mode,
the Classic Learn Mode will exit. LEO will turn off. The device will auto-
reset and then activate SmartStart Learn Mode again.| 1. Issue Wake Up
Notification and stay awake for IS seconds unless put to sleep by Wake Up No
More information frame.
LED will flash green once.
2. Exit Classic exclusion Learn Mode:
If the tamper switch is clicked again during the Classic exclusion Learn Mode,
the Classic Learn Mode will exit. LEO will turn off.
Click tamper switch twice| Reserved| Start a link test with the
controller (When activated by configuration parameter 53). If success, LEO
will blink green two times If failure, LEO will blink red two times
Click tamper switch three times quickly| 1. Send Node info for Adeline.
LED will blink green and red for the 30s until it is added to the network.
If Adding succeeds, LEO will light up green for 2 seconds if Adding fails. LEO
will turn off. The device will auto-reset and then activate SmartStart Learn
Mode again.
2. Exit Classic Inclusion Learn Mode:
If the tamper switch is clicked again during the Classic inclusion Learn Mode,
the Classic Learn Mode will exit. LEO will turn off. The device will auto-
reset and then activate SmartStart Learn Mode again.| 1. Send Node Info
for Removing.
LED will blink green and red for 30 seconds until it is removed from the
network. if Removing succeeds, LEO will light up green for 2 seconds If
Removing fails, LEO will turn off.
2. Exit Classic exclusion Learn Mode:
if tamper switch is clicked again during the Classic exclusion Learn Mode, the
Classic Learn Mode will exit. LEO will turn off.
Click tamper switch 5 times quickly| Reserved| Toggle configuration
parameter 1 setting value from 0/1
Press and hold tamper switch for 5 seconds| Factory Reset.
push the tamper for 5 seconds until the RED LED blinks once. Then release
tamper and push it again for 5 seconds while the RED LEO is blinking until the
GREEN LED blinks once.| Factory Reset.
push the tamper fors seconds until the RED LED blinks once. Then release
tamper and push it again for 5 seconds while the RED LED is blinking until the
GREEN LED blinks once.
| | The device will issue a Device Reset Locally Command via its Lifeline to
notify the Lifeline destination that the device has been reset to its factory
default state. And it will perform the reset operation regardless of whether
or not the delivery of the Device Reset Locally Notification is successful.
---|---|---
Supported Command Classes
Command Class| Versio| Not added| Non-secure add|
Securely 2 added
Non-secure| Sec ure
---|---|---|---|---|---
ZWAVEPLUS_INFO| 2| Support| Support| Support|
ASSOCIATION| 2| Support| Support| | Support
MULTI_CHANNEL_ASSOCIATION| 3| Support| Support| | Support
ASSOCIATION_GRP_INFO| 3| Support| Support| | Support
TRANSPORT_SERVICE| 2| Support| Support| Support|
VERSION| 3| Support| Support| | Support
MANUFACTURER_SPECIFIC| 2| Support| Support| | Support
DEVICE_RESET_LOCALLY| 1| Support| Support| | Support
INDICATOR| 3| Support| Support| | Support
POWERLEVEL| 1| Support| Support| | Support
BATTERY| 1| Support| Support| | Support
SENSOR_BINARY| 2| Support| Support| | Support
CONFIGURATION| 4| Support| Support| | Support
CENTRAL SCENE| 3| Support| Support| | Support
SECURITY_2| 1| Support| Support| Support|
NOTIFICATION| 8| Support| Support| | Support
WAKE_UP| 2| Support| Support| | Support
SUPERVISION| 1| Support| Support| Support|
FIRMWARE_UPDATE_MD| 5| Support| Support| | Support
Basic Command Class mapping
Basic Command Class is not mapped to any of the supported command classes.
Z-Wave Plus Info
Parameter | Value |
---|---|
Z-Wave Plus Version | 0x02 |
Role Type | 0x06 [ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_SLEEPING_REPORTING] |
Node Type | 0x00 [ZWAVEPLUS_INFO_REPORT_NODE_TYPE_ZWAVEPLUS_NODE) |
Installer Icon Type | 0x0C00 [ICON_TYPE_GENERIC_SENSOR_NOTIFICATION] |
User Icon Type | 0x0C00 [ICON_TYPE_GENERIC_SENSOR_NOTIFICATION] |
Manufacturer Specific
Parameter | Value |
---|---|
Manufacturer ID 1 | 0x03 |
Manufacturer ID 2 | 0x71 |
Product Type ID 1 | 0x00 [EU], 0x01 [US], 0x02 [AU] |
Product Type ID 2 | 0x02 [PRODUCT_TYPE_ID_SENSOR] |
Product ID 1 | 0x00 |
Product ID 2 | 0x0C |
Version
Parameter | Value |
---|---|
Z-Wave Protocol Library Type | 0x03 |
Z-Wave Protocol Version | 0x07 |
Z-Wave Protocol SubVersion | 0x0C |
Firmware 0 Version | 0x01 [Z-Wave Chip Firmware Version] |
Firmware 0 SubVersion | 0x00 [Z-Wave Chip Firmware Sub Version] |
Hardware Version | 0x01 |
Number of firmware targets | 0x00 |
Association Group Info
Root product
ID | Name | Node count | Profile | Function |
---|---|---|---|---|
1 | Lifeline | 5 | General: Lifeline | |
(0x0001) | Product Reset Locally Notification: |
Issued when Factory Reset is performed.
Battery Report:
Issued when battery becomes low.
Sensor Binary Report:
Issued when tilt angle is changed
Issued when sensor state is changed.
Notification Report [Type=0x06; Event=0x16]:
Issued when sensor state is changed to be Open Status.
Notification Report [Type=0x06; Event=0x17]:
Issued when sensor state is changed to be Close Status.
Notification Report [Type=0x07; Event=0x03]:
Issued when tamper is tripped
Central Scene Notification:
Issued when the external dry contact is activated
2| Control| 5| Control: Key01
(0x2001)| Basic Set:
Control devices when a magnet or external dry contacts trips
3| Alarm| 5| Notification: Access
Control (0x7106)| Notification Report:
Sends out alarm message when a magnet or external dry sensor trips
4| Tamper| 5| Notification: home
Security (0x7107)| Notification Report:
Sends alarm messages when tamper is tripped
5| Tilting| 5| Control: Key02 (0x2002)| Basic Set:
Control devices when tilting sensor trips
Notification
Notification Type | Notification Events | Description | |
---|---|---|---|
Access Control | 0x06 | Window/Door is open | 0x16 |
Window/Door is closed | 0x17 | Close Status. | |
Home Security | 0x07 | Tamper Removed | 0x03 |
0x00 | State idle | 0x00 | Going to idle |
Binary Sensor
Sensor Type | Sensor Value | Description | |
---|---|---|---|
Door/Window | 0x0A | 0x00 / 0xFF | Door/Window State |
Tilt | 0x0B | 0x00 / 0xFF | tilt event |
CENTRAL SCENE
When activated by configuration parameter #14 the device can perform as a scene controller. Digital + VCC is used to connect the scene button. The external dry contact will then act as a scene controller with a total of 7 scenes that can be activated:
- 1 – Contact Pressed 1 time
- 2 – Contact Pressed 2 time
- 3 – Contact Pressed 3 time
- 4 – Contact Pressed 4 time
- 5 – Contact Pressed 5 time
- 6 – Contact held down
- 7 – Contact released
Slow Refresh = 0, A new Key Held Down notification will be sent every 200ms until the key is released.
Wake Up
Parameter | Value | Time |
---|---|---|
Min Wake Up Interval Seconds | 0x000E10 | 3600s [1 hour] |
Max Wake Up Interval Seconds | 0xEFF100 | 15724800s |
Default Wake Up Interval Seconds | 0x093A80 | 604800s [1 week] |
Wake Up Interval Step Seconds | 0x0000F0 | 240s [4 minutes] |
Battery
- The 2.90V or more battery voltage corresponds to 100% battery level, and 2. 60V or less corresponds to 0%.
- If send Battery Get to the device, it will issue Battery Report with battery level to the requester when waked up.
- If waked up or power on, it will detect battery level, and issue Battery Report 0xFF via Lifeline when the battery level is less than the value of configuration parameter 23.
- If the battery level is less than the value of configuration parameter 23 , LED will flash red 3 times for each wake-up.
Indicator
Indicator ID| | Property ID|
---|---|---|---
Node Identify
(Green Led)| 0x50| On Off Period| 0x03
On Off Cycles| 0x04
On-time within an On/Off period| 0x05
FCC Caution.
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions:
- This device may not cause harmful interference
- this device must accept any interference received, including interference that may cause undesired operation.
Any Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.