Z-Stick 7 user guide.
Modified on: Tue, 29 Jun, 2021 at 1:11 PM
User Guide
Z-Stick 7 Z-Wave Plus USB Antenna
Z-Stick 7 was developed to control actuators and sensors in a Z-Wave Plus
Network as a self-powered Z-Wave® USB Adapter. It is powered by
(https://aeotec.com/z-wave-home-automation/z-wave-gen7.html)Series 700
(https://aeotec.com/z-wave-home-automation/z-wave-700-series.html) and Gen7
(https://aeotec.com/z-wave-home-automation/z-wave-gen7.html) technology
utilizing SmartStart (https://aeotec.com/z-wave-home-automation/z-wave-smart-
start.html) native integration and S2 (https://aeotec.com/z-wave-s2/)
security.
The technical specifications of Z-Stick 7
(https://aeotec.freshdesk.com/support/solutions/articles/6000230554) can be
viewed at that link.
Important safety information.
Please read this and other device guides carefully. Failure to follow the
recommendations set forth by Aeotec Limited may be dangerous or cause a
violation of the law. The manufacturer, importer, distributor, and/or reseller
will not be held responsible for any loss or damage resulting from not
following any instructions in this guide or in other materials.
Keep product and batteries away from open flames and extreme heat. Avoid
direct sunlight or heat exposure. Improper battery use may damage the product.
Z-Stick 7 is intended for indoor use in dry locations only. Do not use in
damp, moist, and/or wet locations.
Quick start.
The following will step you through using Z-Stick 7 when it is attached to a
host controller (PC) as a primary controller.
Please make sure the host controller is pre-installed; this includes any
drivers that the corresponding OS may need. In most cases, the host controller
automatically installs the required USB drivers.
If not, the USB driver can be downloaded from www.silabs.com part CP2102N
which can be found here: SiLabs CP2102N Driver
(https://www.silabs.com/products/development-tools/software/usb-to-uart-
bridge-vcp-drivers).
- Plug Z-Stick 7 into a host controller (that can be a PC, Mac, RPi, etc).
- Windows – Open up “Ports & LPT” under Device Manager. The Z-Stick 7 shows as a COMX device (where X can be a number value range of 0 – 1000).
- Linux – under your command prompt, type in “dmesg | grep tty” which will give you a list of all the devices connected. Z-Stick 7 will show as a “ttyUSB0” device.
- OSX – Choose Apple > System Preferences, then click “Network”. You can find Z-Stick 7 as a USB Modem device “/dev/cu.USB modem”.
- Open the selected third-party software.
- Following your third-party software instructions for connecting a Z-Wave USB adapter. Select the COM or virtual port Z-Stick 7 is associated with.
In most cases, any devices already paired with Z-Stick 7 network will automatically show up in the software’s interface, it may require you to rescan the Z-Stick 7 in order to re-detect devices it has not detected before.
Advanced use.
SerialAPI-Mode.
To initiate SerialAPI-Mode, plug Z-Stick into the USB connector of the host
(i.e. PC, Mac, or Gateway).
- While in SerialAPI-mode, Z-Stick is always listening (it is awake and always in RX receive mode) for instructions and acts as a Z-Wave adapter, and responds to commands sent through USB by the host processor software.
Development and debug tools.
You can utilize PC Controller 5 or previously known as Zensys Tools to be used
as a debug or testing tool for any Z-Wave device. PC Controller 5 allows a
bare basic interface that will allow you to further explore Z-Wave and how it
communicates, and even control or test specific functions of any Z-Wave
device.
You can find steps to getting your hands on the tool here: PC Controller 5
(https://aeotec.freshdesk.com/support/solutions/articles/6000226205-z-wave-
command-class-configuration-tool-download-).
You’ll need to download the Z-Wave development environment Simplicity Studio
in order to access all public development tools.
Current compatible software and setup guides.
In order for the Z-Stick 7 to be used with your software of choice, it must
support the Z-Wave bridge library. Below is a list of all the known software
that is compatible with Z-Stick 7 and how to set them up.
- Setup Z-Ware software (https://aeotec.freshdesk.com/support/solutions/articles/6000232801)
- (https://help.aeotec.com/a/solutions/articles/6000246295) Setup Home Assistant with Raspberry Pi (https://help.aeotec.com/a/solutions/articles/6000246295)
Adding Z-Stick to a Pre-existing Z-Wave network.
This must be done through the host software which takes control of the Z-Stick
USB adapter while the Z-Stick is in SerialAPI-Mode. Please consult the
instruction manual of the host software to add the Z-Stick to a pre-existing
Z-Wave network (i.e. “Learn”, “Sync”, “Add as Secondary Controller”, etc.).
This function can only be performed via host software.
Reset your Z-Stick.
Z-Stick also can be reset to the factory default settings via the host
software.
- The host software must take control of the Z-Stick USB adapter while the Z-Stick is in SerialAPI-Mode.
- Find the Reset Z-Wave controller option/button/function in your chosen software.
References
- Silicon Labs
- Products – Aeotec
- Smart Home Products - Aeotec
- Z-Wave command class configuration tool download. : Aeotec Help Desk
- Z-Stick 7 technical specifications. : Aeotec Help Desk
- Silicon Labs
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>