AEOTEC AEOEZWA019 Z-Wave Plus Water Sensor 7 Pro User Guide
- October 30, 2023
- Aeotec
Table of Contents
- AEOEZWA019 Z-Wave Plus Water Sensor 7 Pro
- Package contents:
- Important safety information.
- Install your Water Sensor 7 Pro.
- Adding your Water Sensor 7 to Z-Wave network.
- Functions of Water Sensor 7 Pro.
- LED indicator.
- Button Function.
- Advanced Functions.
- Firmware-Update over the Air.
- Send a wake-up notification.
- Remove your Water Sensor 7 from Z-Wave network.
- Reset your Water Sensor 7.
- Association Groups
- Parameter setting.
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Water Sensor 7 Pro user guide (ZWA019)
Modified on: Thu, 25 Aug, 2022 at 6:48 PM
Aeotec Water Sensor 7 Pro.
AEOEZWA019 Z-Wave Plus Water Sensor 7 Pro
Aeotec Water Sensor 7 has been crafted as a safety sensor to help detect and
prevent floods and water leaks using ZWave Plus. It is powered by Aeotec’s
Gen7 (https://aeotec.com/z-wave-home-automation/z-wave-gen7.html) technology
and S2 framework. You can find out more about Water Sensor 7 by following that
link.
To see whether Water Sensor 7 is known to be compatible with your Z-Wave
system or not, please reference our Z-Wave gateway comparison
(http://aeotec.com/z-wave-gateways) listing. The technical specifications of
Water Sensor 7 (https://aeotec.freshdesk.com/a/solutions/articles/6000218908
-door-window-sensor-7-technical-specifications-) can be viewed at that link.
Familiarize yourself with your Water Sensor 7.
Package contents:
1. Sensor Unit.
2. Cover.
3. Double-Sided Tape large (×2).
4. Screws (×4).
5. Dowels( x4).
Important safety information.
Please read this and other device guides carefully. Failure to follow the recommendations set forth by Aeotec Limited may be dangerous or cause a violation of the law. The manufacturer, importer, distributor, and/or reseller will not be held responsible for any loss or damage resulting from not following any instructions in this guide or in other materials.
Keep product and batteries away from open flames and extreme heat. Avoid
direct sunlight or heat exposure. Always remove all batteries from products
that are being stored and not used. Batteries may damage the appliance if they
leak. Do not use rechargeable batteries. Ensure correct polarity when
inserting the batteries. Improper battery use may damage the product.
Water Sensor 7 is intended for indoor use in dry locations only. Do not use in
damp, moist, and/or wet locations.
It contains small parts; keep away from children.
Quick Start
Installation of Water Sensor 7 Pro.
- Open the cover by pressing the clip on the side and pulling the cover upwards.
- Insert a fresh 1 * 1/2 AA battery, but pay attention to the polarity
Install your Water Sensor 7 Pro.
The Water Sensor 7 should be placed wherever you want to monitor for possible
flooding or leaks. When placing the
Water Sensor 7, consider the direction in which a flood or leak may flow and
where it may occur. The contacts of the
Water Sensor 7 probe will detect the liquid, so the probe must be placed so
that any flood or leak will come into contact
with it. When the probe contacts come into contact with a liquid, the Water
Sensor 7 sends a leak warning to your Z-Wave
Gateway. Make sure that both contacts are capable of detecting leaks or
flooding.
Adding your Water Sensor 7 to Z-Wave network.
Dedicated hub setup guides:
- Aeotec AutoPilot (https://aeotec.freshdesk.com/support/solutions/articles/6000247465-setup-water-sensor-7-withautopilot)
- Aeotec Smart Home Hub / SmartThings (https://aeotec.freshdesk.com/support/solutions/articles/6000247466setup-water-sensor-7-with-aeotec-smart-home-hub)
- Home Assistant / Z-WaveJS (https://aeotec.freshdesk.com/support/solutions/articles/6000247467-setup-watersensor-7-with-home-assistant)
- Hubitat (https://aeotec.freshdesk.com/support/solutions/articles/6000247468-setup-water-sensor-7-with-hubitat)
SmartStart Inclusion.
You can use this method of inclusion only if your Z-Wave
gateway/controller/hub supports SmartStart.
- Open up your Z-Wave gateway/controller/app.
- Select SmartStart inclusion.
- Scan the QR code located on the Water Sensor 7.
- Within 10 minutes after powering your Water Sensor 7, it will automatically get included in your Z-Wave gateway/controller/hub.
Classic Inclusion
- Set your Z-Wave controller into pairing mode.
- Triple-click the tamper switch on Water Sensor 7 – this begins to blink five times
- After completion of the inclusion, the LED will illuminate green for 3 seconds.
- If you pairing with S2 encryption/security, enter the first 5 digits of the DSK into your controller/gateway/hub interface when requested.
- Close the cover
Functions of Water Sensor 7 Pro.
Water leak
Once installed, this sensor will report wet or dry via Notification Command
Class when this device is wet or removed from water.
- Notification Report
- Type: Unknown (0x05)
- Value: Wet (0x02) or Dry (0x00)
Tamper
Tamper alarm will be sent if the cover is removed.
- Notification Report
- Type: Tamper Removed (0x07)
- Value: 0x03
Temperature
This sensor will report occasionally on its own as an unsolicited Multilevel
Sensor Report either by a timed interval (Parameter 18) or by the change in
value (Parameter 16).
Multilevel Sensor Report
Humidity
This sensor will report occasionally on its own as an unsolicited Multilevel
Sensor Report either by a timed interval (Parameter 18) or by the change in
value (Parameter 17).
Multilevel Sensor Report
LED indicator.
Function Description | LED Indicator |
---|---|
Device Not in Network | Blinks red for 5 seconds (1 sec duty cycle) when |
battery is inserted and sensor is not in network
Include/Exclude/Leam Mode| Illuminate green for 3 seconds when Inclusion
/ Exclusion / Configuration is successful.
Illuminate red for 3 seconds when Inclusion / Exclusion / Configuration is
unsuccessful (upon a timeout of 30 seconds).
Local Reset| When device is locally reset to Factory Default LED blinks
red (1 second duty cycle) for 5 seconds.
LowBatt| When operation button is Short Pressed the LED blinks red three
time (1 sec duty cycle)
Tampering| If either Tamper Switch 1 or 2 is activated the device blinks
red one time with’/ second duty cycle if within range of Controller.
The device blinks red three times with 1/2 second duty cycle if out of range
of Controller
Water protection| When operation button is Short Pressed the LED
illuminates red three seconds in case of Water Leakage detected and Green if
no Leakage detected.
Button Function.
Push Type | Function | Description |
---|---|---|
Long Press 5s | Pending reset | LEDs start indication Waiting for Reset. |
Long Press 10s | Reset | Initiates Device Reset Locally. |
Short Press | Tamper | Sends Wake Up notification. |
3 Times Short Press | Sequence | See Learn Mode. |
Advanced Functions.
Communication test.
This utilizes the Power Level command class to determine the health between
the Water Sensor 7 and your Z-Wave gateway. This will tell you if the Water
Sensor 7 has a healthy connection to your system and is a great method of
debugging connectivity issues.
- Set Parameter #4 to value #1
- Double click the Tamper Switch.
- Result:
• Green LED blinks once – success
• Red LED blinks 3x times – failure
Firmware-Update over the Air.
This device is capable of receiving a new firmware ‘over the air’. The update function needs to be supported by the central controller. Once the controller starts the update process, perform the following action to confirm the firmware update:
- Wake Up the device by removing the cover.
- Hit the tamper switch once.
Send a wake-up notification.
In order to send your sensors new configuration commands from your Z-Wave controller or gateway, it will need to be woken up.
- Wake Up the device by removing the cover.
- Hit the tamper switch once.
Note: Water Sensor 7 remains awake until the housing is closed again.
Remove your Water Sensor 7 from Z-Wave network.
Your sensor can be removed from your Z-Wave network at any time. You’ll need to use your Z-Wave network’s main controller/gateway. To do this, please refer to the part of your gateways respective manual that tells you how to remove devices from your network.
- Set your Z-Wave controller into unpair mode.
- Triple-click the tamper switch on Water Sensor 7 within 1.5 seconds – this will cause the LED to blink five times.
- After a successful exclusion, it will light up its LED for 2 seconds then deactivate.
Reset your Water Sensor 7.
This device also allows being reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
To manually factory reset:
- Remove the cover of Water Sensor 7
- Press and hold tamper switch for 5 seconds until the red LED blinks.
- Release the tamper switch
- Immediately press and hold the tamper switch for 5 seconds until the red LED blinks.
Association Groups
Group Association allows Water Sensor to directly communicate with other Z-Wave devices directly without the need for the Z-Wave Controller to act as an in-between controller. This using this function will help with communication efficiency and limit the amount of time it takes to control a device.
Group
Number| Maximum
Nodes| Description
---|---|---
1| 5| Lifeline
2| 5| Control devices when water leakage is detected
3| 5| Sends out alarm message when water leakage is
detected
4| 5| Sends alarm messages when tamper is tripped
Parameter setting.
3. Visual LED indications
Parameter: 3
Size: 1 Byte
Default Value: 7
Description:
This parameter defines when the red LED will indicate events. Disabling all
indications may extend battery life. (values 1 + 2 + 4 summarized)
0 – No indications
1 – Water Leakage Status Change
2 – Wake Up (1 x click) 4 – Device tampering
4. Range test after double click
Parameter: 4
Size: 1 Byte
Default Value: 0
Description:
Allows enabling the activation of a Z-Wave range test with double-clicking the
tamper switch.
0 – disabled
1 – enabled
5. 2nd Association Group Trigger
Parameter: 5
Size: 1 Byte
Default Value: 0
Description:
This parameter defines the status of the water leakage that causes sending a
BASIC command to all devices of Association Group 2.
0 – Switch after Water Leakage Start and Stop
1 – Switch after Water Leakage Start
2 – Switch after Water Leakage Stop
6. Command Sent to Devices of Association Group 2
Parameter: 6
Size: 1 Byte
Default Value: 255
Description:
This parameter defines which commands are sent to 2nd Association Group 0 – On
1 – Off 2 – On and Off
7. BASIC command value sent to 2nd Association Group on On event
Parameter: 7
Size: 1 Byte
Default Value: 255
Description:
This is the BASIC command value sent in case of On even 0 – 99 – Value 255 –
On
8. BASIC command value sent to 2nd Association Group on Off event
Parameter: 8
Size: 1 Byte
Default Value: 0
Description:
This is the BASIC command value sent in case of Off event. 0 – 99 – Value 255
– On
9. Time Delay of On command frame
Parameter: 9
Size: 2 Byte
Default Value: 0
Description:
On command is sent after a delay defined in this parameter. 0 – 32400 –
Seconds
10. Time delay of Off command frame
Parameter: 10
Size: 2 Byte
Default Value: 0
Description:
Off command is sent after a delay defined in this parameter. 0 – 32400 –
Seconds
11. Delay of tamper alarm cancellation.
Parameter: 11
Size: 2 Byte
Default Value: 0
Description:
Time a tamper alarm is delayed. 0 – 32400 – Seconds
12. Reporting tamper alarm cancellation
Parameter: 12
Size: 1 Byte
Default Value: 1
Description:
This parameter defines if the alarm cancellation event is reported. 0 – do not
send report 1 – send report
16. Minimum temperature change to report.
Parameter: 16
Size: 1 Byte
Default Value: 20
Description:
This value defines the minimum change of temperature to cause an unsolicited
report of temperature to the central controller using Lifeline. If the value
is set to 0, there will be no reports sent to the controller, when the
temperature changes. However, periodic reports, managed by configuration
parameter 18, may still be active.
0 – disabled
1-100 – 0,1 degree step
17. Minimum humidity change to report.
Parameter: 17
Size: 1 Byte
Default Value: 5
Description:
This value defines the minimum change of humidity to cause an unsolicited
report of humidity to the central controller using Lifeline. If the value is
set to 0, there will be no reports sent to the controller, when the humidity
changes. However, periodic reports, managed by configuration parameter 18, may
still be active.
0 – disabled
1-20 – value in %
18. Periodic Reports.
Parameter: 18
Size: 2 Byte
Default Value: 43200
Description:
This parameter defines the time interval to send an unsolicited report. If the
value is set to 0, there will be no periodic reports sent to the controller.
However, reports on temperature/humidity changes, managed by configuration
parameters 16 and 17, may still be active.
0 – disabled
900-65535 – value in seconds
64. Temperature Scale
Parameter: 64
Size: 1 Byte
Default Value: 1
Description:
This parameter sets the temperature scale.
1 – Celsius
2 – Fahrenheit
255. Reset Parameter
Parameter: 255
Size: 4 Byte
Default Value: 0
Description:
This parameter helps reset configuration parameters and the device to factory
defaults
1- Reset all Parameter settings to their default settings.
1431655765 – (0x55555555) Completely factory reset sensor and send device
reset locally notification
References
- Controllers – Aeotec
- Support – Aeotec
- Loading...
- Setup Water Sensor 7 with AutoPilot : Aeotec Help Desk
- Setup Water Sensor 7 with AutoPilot : Aeotec Help Desk
- Setup Water Sensor 7 with Aeotec Smart Home Hub : Aeotec Help Desk
- Setup Water Sensor 7 with Aeotec Smart Home Hub : Aeotec Help Desk
- Setup Water Sensor 7 with Home Assistant : Aeotec Help Desk
- Setup Water Sensor 7 with Home Assistant : Aeotec Help Desk
- Setup Water Sensor 7 with Hubitat : Aeotec Help Desk
- s3.amazonaws.com/cdn.freshdesk.com/data/helpdesk/attachments/production/6093719007/original/WdQM6U7A2h6DDThMfBIY7HnD4NJZsTyUZA.png?1570780984
- s3.amazonaws.com/cdn.freshdesk.com/data/helpdesk/attachments/production/6093719009/original/xSqwjLNn7xB8x0R5dJlTlF3SM0BYgqGlsQ.png?1570780985
Read User Manual Online (PDF format)