SCHLAGE LEBMS-ADD LE Networked Wireless Mortise Lock Instruction Manual

June 6, 2024
Schlage

LE Networked Wireless
Mortise Lock
Installation Instructions

Access online interactive instructions, user guide, warranty, and reference information.
alle.co/LE

https://alle.co/LE-qr

Compatible Cylinder Measurements

Door
Thickness| Minimum Cylinder
Length| Maximum Cylinder Length
---|---|---
PA”| 13/4″ (without spring)| 1W
2″| 1%” (without spring)| 1%”
21/4″| 11/2″| 13/4″ (with spring)

If your cylinder measurements are not compatible, contact Customer Service for assistance.
Customer Service 1-877-671-7011 www.allegion.com/us

ENGAGE™ WEB & MOBILE APPLICATIONS
Search for “Allegion ENGAGE” where you obtain apps to download the app.
Navigate to portal.allegionengage.com to access your account online.
Installation Preparation
Tools Needed

  • 1 and #2 Phillips screwdriver

  •  Lever installation tool (included in box)
  •  Needle-nose pliers

Optional

  • Drill with 3/8” drill bit
  • Tamper-proof Torx drivers

Door preparation:

Contact Product Support at 1-877-671-7011.

IMPORTANT NOTES
All images are shown in the manual show RH installation.
Do NOT use an impact driver to install the product.
Install and test lock with door open to avoid being locked out!
NOTICE
Notices indicate a condition that may cause equipment or property damage only.

A. Adjust door handing if needed.
RX (request to exit) utilizes a microswitch inside the lock case to detect rotation of the inside knob/lever.
The RX is a removable module located on the bottom edge of the lock chassis. The module must be properly positioned to detect inside knob/lever rotation. If not properly positioned, the lock and/or microswitch may be damaged.

If handing screw is NOT on the INSIDE of the door follow A1 and A2 steps.
A1. Carefully remove the RX module and handing screw.
NOTICE
Handing screw and microswitch must be on the INSIDE of the door. If handing screw and microswitch are already on the INSIDE of the door, do not remove them.

The RX module has a microswitch on one side and a connector on the other.
A2. Reinstall the handing screw onto the inside of door, then reinstall RX module with the microswitch also on the inside of the door.
A3. Rotate the latch 180° (if necessary). B. Install strike.

C. Deadbolt (LEMD) Only: Install door position switch and magnet.
Feed the wires from the connector on the door position switch into the long angled hole in the door. Plug the connector into the chassis. Do not push in switch all the way, leave a little slack until the chassis is installed after step 1.
NOTICE
Make sure the door position magnet in the jamb is aligned with the switch in the door edge!

Installation Instructions for Sectional Trim

  1. Install chassis.
    Route chassis connector through the upper 5/8” hole on the interior side of the door, and pull through the slack as you slide chassis into the mortise. You may use needle-nose pliers to gently pull the cable through the hole.

  2. Install lever spindle on the exterior side of the door.
    Install spring on lever spindle.

  3. Install spring cage into lever.
    Use pliers carefully to install mounting posts to avoid damage.

  4. Install outside lever.

  5. Install the outside trim and route wire all the way through the hole to the interior side of the door.

  6. Partly install the key cylinder.
    Turn key cylinder into the chassis. Tighten just enough to secure outside trim. Insert key, then pull out one notch to aid with turning.
    NOTICE
    Do not tighten more than six full turns! Tighten fully at step 12!

  7. Install inside the spindle, spring cage, and mounting plate.
    Arrow on the mounting plate faces in direction of lever down rotation.

  8. Install the inside rose and lever.

  9. Connect the cables to the inside assembly.
    There are two cables that need to be connected.

  10. Deadbolt (LEMD) Only: Align driver bar into the chassis.
    Thumbturn should be vertical when the deadbolt is retracted.

  11. Install the inside assembly.

  12. Fully tighten the key cylinder and chassis screws.
    The cylinder face needs to be flush to the outside escutcheon.
    Tighten the cylinder mounting screw.

  13. Install the armor plate.

  14. Connect the battery cable.
    Install four (4) AA batteries into the battery holder. Tuck the cable behind the tab in the escutcheon.
    Electrical Ratings (6Vdc, 500mA, 3 W)
    Power On Self Test (POST)
    The POST is a self-diagnostic test that the lock runs to verify that the lock is installed correctly. The POST takes approximately 30 seconds after batteries are installed. During the POST, a series of audible beeps and LED flashes will occur. If the POST detects an issue, the test will conclude with three red flashes of the outside LED. Once commissioned with the ENGAGE mobile app, any issues identified during POST can be viewed under the View Activity menu.

  15.  Install the battery cover and tighten the screw.
    15a Optional: Install security screw and washer. Remove standard screw and washer and replace with security screw and washer.

  16. Continue to User Guide.
    Your lock is now completely installed.

Access online interactive instructions, user guide, warranty, and reference information.

https://alle.co/LE-qr

Installation Instructions for Escutcheon Trim

  1. Install chassis.
    Route chassis connector through the upper 5/8” hole on the interior side of the door, and pull through the slack as you slide chassis into the mortise. You may use needle-nose pliers to gently pull the cable through the hole.

  2. Install lever spindle on the exterior side of the door.
    Install spring on lever spindle.

  3. Install mounting posts and spring cage.
    Arrows on the spring cage point in direction of lever down rotation. Use pliers to carefully install mounting posts to avoid damage.

  4. Install the outside trim and route wire all the way through the hole to the interior side of door.

  5. Partly install the key cylinder.
    Turn key cylinder into the chassis. Tighten just enough to secure outside trim. Insert key, then pull out one notch to aid with turning.

  6. Install inside spindle, spring cage, and mounting plate.
    Arrows on the spring cage point in direction of lever down rotation.

  7. Connect the cables to the inside assembly
    There are two cables that need to be connected.

  8. Install the inside assembly.

  9. Fully tighten the key cylinder and chassis screws.
    The cylinder face needs to be flush to the outside escutcheon. Tighten the cylinder mounting screw.

  10. Install the armor plate.

  11. Connect the battery cable.
    Install four (4) AA batteries into the battery holder. Tuck the cable behind the tab in the escutcheon
    Electrical Ratings (6Vdc, 500mA, 3 W)
    Power On Self Test (POST)
    The POST is a self-diagnostic test that the lock runs to verify that the lock is installed correctly. The POST takes approximately 30 seconds after batteries are installed. During the POST, a series of audible beeps and LED flashes will occur. If the POST detects an issue, the test will conclude with three red flashes of the outside LED. Once commissioned with the ENGAGE mobile app, any issues identified during POST can be viewed under the View Activity menu.

  12. Install the battery cover and tighten the screw.
    12a Optional: Install security screw and washer.
    Remove standard screw and washer and replace with security screw and washer.

  13. Install the inside lever.

  14. Continue to User Guide.
    Your lock is now completely installed.

Access online interactive instructions, user guide, warranty, and reference information.
alle.co/LE

https://alle.co/LE-qr

Customer Service
1-877-671-7011
www.allegion.com/us

Factory Default Reset (FDR)

A Factory Default Reset (FDR) will return the LE-series lock settings to the original settings as shipped from the factory.
Removes configurations, databases, and requires the lock to be re-captured. An FDR will not remove the lock from your ENGAGE account.
A. Press and hold the FDR button for five seconds.

The LED will blink green two times and beep two times.
B Turn the inside lever three times within 20 seconds.
LED will blink red and the lock will beep with each turn.
C. Reinstall the battery cover, then use the app to capture your lock.
Turn the inside lever. The LE will communicate on BLE looking for your mobile device for two minutes after each lever turn in FDR mode.
If you have used this LE in Construction Access Mode, you must complete an FDR before it will communicate on BLE.

FCC Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC  Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communication. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FCC Radiation Exposure Statement
To comply with FCC/IC RF exposure requirements for mobile transmitting devices, this transmitter should only be used or installed at locations where there is at least 20 cm separation distance between the antenna and all persons.
Industry Canada Statement
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted for successful communication.

UL Statements

  • LEB models use Bluetooth credentials.
  • The outside lever is normally locked. Inside lever always allows egress.
  • The system shall not be installed in the fail-secure mode unless permitted by the local authority having jurisdiction and shall not interfere with the operation of Listed panic hardware.
  • Unit shall not interfere with the operation of Panic Hardware.
  • Wireless communications, Wi-Fi, Bluetooth, Door Position, and Request to Exit switch features are not part of the UL Listed product.
  • Tested to comply with UL 294 7th Edition.
  • Tested to compliance with CAN/ULC-S319-05, Class I.
Destructive Attack IV Line Security Endurance Standby Power
IV I IV I
  • Access Control Performance Levels
  • Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), CSA 22.1, Canadian Electrical Code (CEC), Part I, Safety Standard for Electrical Installations, local code, and the authorities having jurisdiction.
  • This product is not intended for outside wiring as covered by Article 800 in the National Electrical Code, NFPA 70.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>