QUBINO Mini Dimmer ZMNHHD3 Manual

June 8, 2024
QUBINO

QUBINO

Mini Dimmer

SKU: ZMNHHD3

Quickstart

This is a
secure
Light Dimmer
for
.

To run this device please connect it to your mains power supply.

Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.

Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This
device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message ( two- way
communication
) and every mains powered node can act as a repeater for other nodes
( meshed network ) in case the receiver is not in direct wireless range of the
transmitter.

This device and every other certified Z-Wave device can be used together with any other
certified Z-Wave device regardless of brand and origin
as long as both are suited for the
same frequency range.

If a device supports secure communication it will communicate with other devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to maintain
backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer
to www.z-wave.info.

Product Description

Mini Dimmer is a MOSFET-switching light device that also supports control of low-voltage halogen lamps with electronic transformers, dimmable compact fluorescent lights, and dimmable LED bulbs. It measures power consumption of the connected device. It supports push-button/momentary switches (default) and toggle switches. It can work with or without the neutral line. Qubino Mini Dimmer allows the easiest and quickest installation. It is designed to be mounted inside a flush mounting box, hidden behind a traditional wall switch. It acts as repeater in order to improve range and stability of Z-Wave network. Supports SmartStart

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default
state.
Please make sure to reset the device into factory default. You can do this by
performing an Exclusion operation as described below in the manual. Every Z-Wave
controller is able to perform this operation however it is recommended to use the primary
controller of the previous network to make sure the very device is excluded properly
from this network.

Safety Warning for Mains Powered Devices

ATTENTION: only authorized technicians under consideration of the country- specific
installation guidelines/norms may do works with mains power. Prior to the assembly of
the product, the voltage network has to be switched off and ensured against re-switching.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs
to be added to an existing wireless network to communicate with the devices of this network.
This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network. This
controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is
then performed doing a special manual action right on the device.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association – one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device
controlling another device is called association. In order to control a different
device, the controlling device needs to maintain a list of devices that will receive
controlling commands. These lists are called association groups and they are always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’ Command.

Association Groups:

Group NumberMaximum NodesDescription

1| 1| Lifeline.Supports the following command classes:Device Reset Locally: triggered upon requestMeter Report: triggered according to Configuration parameters 40 and 42Notification Report: triggered on overload/over heatingSwitch Multilevel Report: triggered upon request or according to Configuration parameters 11 and 12.Switch Binary Report: triggered upon request or according to Configuration parameters 11 and 12.
---|---|---
2| 16| Supports the following command classes:Basic set: triggered at the change of the output and reflecting its state
3| 16| Supports the following command classes:Start/Stop Level Change: triggered upon holding and releasing the switch connected to terminal I
4| 16| Supports the following command classes:Switch Multilevel Set: triggered at change of output and reflecting its state

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock further
enhanced features.

IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56.
In case of a two byte value the same logic applies: Values greater than 32768 may
needed to be given as negative values too.

Parameter 1: In-wall Switch Type for Load to control I1

With this parameter, you can select between push-button (momentary) and on/off toggle switch types.
Size: 1 Byte, Default Value: 0

SettingDescription

0 push-button (momentary)
1 on/off toggle switch

Parameter 11: Turn Load 1 Off Automatically with Timer

If Load is ON, you can schedule it to turn OFF automatically after a period of time defined in this parameter. The timer is reset to zero each time the device receives an ON or OFF command, either remotely (from the gateway (hub) or associated device) or locally from the switch.
Size: 2 Byte, Default Value: 0

SettingDescription

0 Auto OFF Disabled
1 – 32536 1 – 32536 seconds – Auto OFF timer enabled for a given amount of

seconds

Parameter 12: Turn Load 1 On Automatically with Timer

If Load is OFF, you can schedule it to turn ON automatically after a period of time defined in this parameter. The timer is reset to zero each time the device receives an OFF or ON command, either remotely (from the gateway (hub) or associated device) or locally from the switch.
Size: 2 Byte, Default Value: 0

SettingDescription

0 Auto ON Disabled
1 – 32536 1 – 32536 seconds – Auto ON timer enabled for a given amount of

seconds

Parameter 21: Enable/Disable the Double click function

If the Double click function is enabled, a fast double click on the push- button will set the dimming level to the maximum dimming value.
Size: 1 Byte, Default Value: 0

SettingDescription

0 double click disabled
1 double click enabled

Parameter 30: Restore on/off status for load after power failure

This parameter determines if on/off status is saved and restored for the load after power failure.
Size: 1 Byte, Default Value: 0

SettingDescription

0 Device saves last on/off status and restores it after a power failure.
1 Device does not save on/off status and does not restore it after a power

failure, it remains off.

Parameter 40: Watt Power Consumption Reporting Threshold for Load

Choose by how much the power consumption needs to increase or decrease to be reported. Values correspond to percentages so if 10 is set (by default), the device will report any power consumption changes of 10% or more compared to the last reading. NOTE: The power consumption needs to increase or decrease by at least 2 Watts to be reported, regardless of percentage set in this parameter.
Size: 1 Byte, Default Value: 10

SettingDescription

0 Power consumption reporting disabled
1 – 100 1% – 100% Power consumption reporting enabled. New value is reported

only when Wattage in real time changes by more than the percentage value set in this parameter compared to the previous Wattage reading, starting at 1% (the lowest value possible).

Parameter 42: Watt Power Consumption Reporting Time Threshold for Load

Set value refers to the time interval with which power consumption in Watts is reported (032767 seconds). If 300 is entered, energy consumption reports will be sent to the gateway (hub) every 300 seconds (or 5 minutes) if there was a change compared from the last report.NOTE: Values from 1 to 29 are ignored by device due to standard recommendation.NOTE: The report will be send only if there was a change compared to the last report.
Size: 2 Byte, Default Value: 0

SettingDescription

0 Power consumption reporting on time interval disabled
30 – 32767 30 – 32767seconds. Power consumption reporting enabled. Report is

sent according to time interval (value) set here.

Parameter 6: Load type

With this parameter, you select the load type, dimmable or non dimmable. Device operating in dimmable mode on non dimmable load can lead to device or load malfunction. For non dimmable loads par. 6 must be set to 1. NOTE: When par.6 set to 1 (non dimmable load) values of listed parameters will be ingnored (par.60 min. dimming value, par.61 max. dimming value, par.65 Dimm. Time when key presed par.66 dimm. Time when key hold, par.21 Double click function NOTE: If the bulb is dimmable or non dimmable (generally valid for LED) is shown on the bulb itself or on packaging. NOTE: Parameter 6 is replacing parameter 5. Present in previous version.
Size: 1 Byte, Default Value: 0

SettingDescription

0 Dimmable load
1 Non dimmable load

Parameter 60: Minimum dimming value

The value set in this parameter determines the minimum dimming value (the lowest value which can be set on the device, when, for example, dimming lights with wall switch or slider in the GUI (Gateway – hub)) (Data type 1 byte dec) default value 15 = 15% (minimum dimming value) 0- 98 = 0% – 98%, step is 1%. Minimum dimming value is set by entering a value. NOTE: The minimum level may not be higher than the maximum level!
Size: 1 Byte, Default Value: 15

SettingDescription

0 – 98 0% – 98%, step is 1%. Minimum dimming value is set by entering a value

Parameter 61: Maximum dimming value

The value set in this parameter determines the maximum dimming value (the highest value which can be set on the device, when, for example, dimming lights with wall switch or slider in the GUI (Gateway – hub)) NOTE: The maximum level may not be lower than the minimum level!
Size: 1 Byte, Default Value: 99

SettingDescription

1 – 99| 2 % – 99 %, step is 1 %. Maximum dimming value is set by entering a value.
---|---

Parameter 65: Dimming time when key pressed (soft on/off)

Choose the time during which the device will move between the min. and max. dimming values by a short press of the push-button I1.
Size: 1 Byte, Default Value: 1

SettingDescription

1 1 second
1 – 127 1 seconds- 127 seconds, step is 1 second

Parameter 66: Dimming time when key hold

Choose the time during which the Dimmer will move between the min. and max. dimming values during a continuous press of the push-button I1, by an associated device or through the UI controls (BasicSet, SwitchMultilevelSet).
Size: 2 Byte, Default Value: 3

SettingDescription

1 – 127 1 second127 seconds
128 – 253 1 minute126 minutes

Parameter 67: Ignore start level

Choose whether the device should use (or disregard) the start dimming level value. If the device is configured to use the start level, it should start the dimming process from the currently set dimming level. This parameter is used with association group 3.NOTE: Parameter is valid only in Dimmer mode. In Switch mode the parameter has no effect.
Size: 1 Byte, Default Value: 0

SettingDescription

0 use the start level value
1 ignore the start level value

Parameter 68: Dimming duration

Choose the time during which the device will transition from the current value to the new target value. This parameter applies to the association group 3.NOTE: Parameter is valid only in Dimmer mode. In Switch mode the parameter has no effect.
Size: 1 Byte, Default Value: 0

SettingDescription

0 dimming duration according to parameter 66
1 – 127 from 1 to 127 seconds

Parameter 70: Overload safety switch

_The function allows for turning off the controlled device in case of exceeding the defined power for more than 5s. Controlled device can be turned back on by input I1 or sending a control frame. NOTE: This functionality is not an overload safety protection, please check the technical specifications chapter for more details.In case of overload the following message will be send towards the controller: COMMAND_CLASS_NOTIFICATIONV5 The Alarm V1 type field set to 0x00 Notification Type 0x08 and 0x08 (Overload detected)
Size: 2 Byte, Default Value: 200

SettingDescription

0 function not active
1 – 200 1W – 200W

Parameter 71: Calibration trigger

Choose when will be the calibration procedure triggered.
Size: 1 Byte, Default Value: 0

SettingDescription

1 calibration done after power cycle regardless of inclusion status
2 force calibration. Calibration will start immediately

Parameter 72: Calibration status (read only)

With this parameter you can check the calibration status.
Size: 1 Byte, Default Value: 2

SettingDescription

1 calibration was successful
2 calibration failed

Parameter 73: Alarm/Notification events

This parameter defines the module behaviour in case it receives any Alarm/Notification events.NOTE: When value 3 is selected the default time interval of the blinking is 10 minutes. It can be stopped with a button press or sending a control frame. To adjust the time interval please refer to parameter 74Alarm/Notification time interval.
Size: 1 Byte, Default Value: 0

SettingDescription

1 turn OFF
2 turn ON
3 start blinking (output turns 1s ON, and 1s OFF)

Parameter 74: Alarm/Notification time interval (dependant on parameter

This parameter defines the time interval of the blinking state, once the module receives an alarm/notification event. Minimum step increase is 1 minute.NOTE: This parameter does not have any effect if parameter 73 is not set to value 3.
Size: 1 Byte, Default Value: 10

SettingDescription

1 – 125 1-125 minutes

Technical Data

Hardware Platform ZM5101
Device Type Light Dimmer Switch
Network Operation Always On Slave
Firmware Version HW: 2 FW: 30.10:30.10
Z-Wave Version 6.82.01
Certification ID ZC10-21127065
Z-Wave Product Id 0x0159.0x0001.0x0055
Outdoor Use ok
Switch Type Decorator Paddle Push
Communications Protocol Manufacturer Proprietary Protocol
Supported Notification Types
Color Antique Brass
Supported Meter Type
Security V2 S2_UNAUTHENTICATED ,S2_AUTHENTICATED
Frequency XXfrequency
Maximum transmission power XXantenna

Supported Command Classes

  • Association Grp Info V2
  • Association V2
  • Basic
  • Switch Binary
  • Configuration
  • Device Reset Locally
  • Manufacturer Specific V2
  • Meter V4
  • Notification V8
  • Powerlevel
  • Security 2
  • Supervision
  • Switch Multilevel V3
  • Transport Service V2
  • Version V2
  • Zwaveplus Info V2

Controlled Command Classes

  • Basic
  • Switch Binary
  • Switch Multilevel V3

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network.
    Controllers are typically Gateways,Remote Controls or battery operated wall controllers.

  • Slave — is a Z-Wave device without capabilities to manage the network.
    Slaves can be sensors, actuators and even remote controls.

  • Primary Controller — is the central organizer of the network. It must be
    a controller. There can be only one primary controller in a Z-Wave network.

  • Inclusion — is the process of adding new Z-Wave devices into a network.

  • Exclusion — is the process of removing Z-Wave devices from the network.

  • Association — is a control relationship between a controlling device and
    a controlled device.

  • Wakeup Notification — is a special wireless message issued by a Z-Wave
    device to announces that is able to communicate.

  • Node Information Frame — is a special wireless message issued by a
    Z-Wave device to announce its capabilities and functions.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals