SCHLAGE Legge 9901MF Omnia Smart Lock Instruction Manual

May 15, 2024
Schlage

SCHLAGE Legge 9901MF Omnia Smart Lock

SCHLAGE-Legge-9901MF-Omnia-Smar-Lock-product

Specifications

  • Recommended lock: Legge 991MF or 990MF mortice lock
  • Door thickness: 35mm to 60mm

Product Usage Instructions

  1. Preparing the Door:
    Measure and prepare the door according to the provided dimensions. Ensure the cylinder hole is not required unless using an extension kit.

  2. Fasten Hexagonal Posts:
    Attach the hexagonal screw casings to the studs on the back of the external unit securely.

  3. Adjust Spindle Holder Direction:
    Ensure the spindle holder arrow points in the opposite direction of the lever when using a mortice lock. For a latch, ensure the arrow points down.

  4. Select Correct Length Screws and Spindle:
    Refer to the box contents to select the appropriate screws and spindles based on your door thickness.

  5. Fasten External and Internal Units to Door:
    Securely fasten both units to the door, ensuring the gasket is seated correctly for proper installation.

  6. Install Batteries
    Remove the battery cover using a screwdriver, install 4x AAA alkaline batteries, and resecure the battery cover.

  7. Test Operation:
    Test the operation by rotating the external and internal levers as instructed. Test with the provided code and ignore any Bluetooth administrator voice messages during testing.

  8. Care and Maintenance

  9. Door Furniture
    Regularly check and tighten fixing screws securing the furniture to the door. Wipe clean with a soft damp cloth using mild detergent if needed.

  10. Mortice Lock
    Keep internal components free of dirt and woodchips during installation. Lubricate tubular latches used externally at twelve-month intervals.

  11. Warranty
    Refer to our website for detailed warranty information and exclusions. Goods are covered by guarantees under local consumer law.

FAQ

  • Q: What should I do if the latch bolt does not retract during testing?
    A: Ensure the spindle holder arrow points in the correct direction as per instructions.

  • Q: How often should I lubricate tubular latches used externally?
    A: Lubricate tubular latches with an aerosol lubricant at twelve-month intervals for optimal performance.

Omnia Smart Lock
INSTALLATION INSTRUCTIONS

Box contents Spindle, choose one set:

SCHLAGE-Legge-9901MF-Omnia-Smar-Lock- \(1\)

Fixing screws, choose one set: SCHLAGE-Legge-9901MF-Omnia-Smar-Lock-
\(2\)

Recommended lock

  • Legge 991MF or 990MF mortice lock

Door thickness

  • 35mm to 60mm

Tools required

  • Tape measure
  • Pencil
  • Level
  • Drill
  • Drill bit – 10mm
  • Spade bit – 22mm
  • Hammer
  • Chisel
  • Screwdriver (Phillips)

Scan here for more information on installing the Schlage Omnia Smart Lock

  1. PREPARING THE DOOR
    After preparing the mortice lock as per the instructions of the lock, drill a spindle hole Ø22mm. From the centre of spindle hole, measure a top fixing hole at 160mm and a bottom fixing hole at 85mm, drill Ø10mm fixing holes. Install mortice lock.

  2. FASTEN HEXAGONAL POSTS
    Attach the hexagonal screw casings to the studs on the back of the external unit.

  3. HANDING – EXTERNAL UNIT (AS REQUIRED)
    Using a hex key, remove the holding screw from the lever. Remove the lever, rotate the lever 180° and reattach the lever. Reinstall the securing screw and tighten.

  4. HANDING – INTERNAL UNIT (AS REQUIRED)
    Use a screw driver to remove securing screws.
    Remove the lever, rotate the lever 180° and reattach the lever. Refasten the securing screws.

  5. ADJUST SPINDLE HOLDER DIRECTION
    Ensure the spindle holder arrow points in the opposite direction of the lever when using a mortice lock. When using a latch, ensure the arrow points down.

  6. SELECT CORRECT LENGTH SCREWS AND SPINDLE
    Refer to the front cover for box contents, to select the correct screws and spindles to suit your door thickness.SCHLAGE-Legge-9901MF-Omnia-Smar-Lock-
\(7\)

  7. FASTEN EXTERNAL AND INTERNAL UNITS TO DOOR
    Fasten units to the door, ensuring gasket is seated correctly.

  8. INSTALL BATTERIES
    Use a screwdriver to remove the battery cover. Install 4x AAA alkaline batteries. Resecure the battery cover. SCHLAGE-Legge-9901MF-Omnia-Smar-Lock-
\(8\)

  9. TEST OPERATION
    Rotate the external lever, ensure latch bolt does not retract (refer to step 5). Rotate the internal lever, ensure latch bolt does retract (refer to step 6). Test operation using code 123456#. Ignore Bluetooth administrator voice message when testing code.

CARE AND MAINTENANCE

  • Door Furniture
    At twelve (12) monthly intervals, the fixing screws securing the furniture to the door, both surface fix and through fix, should be checked and tightened as required. Loose fitting furniture which fails will not be covered under warranty.
    All door furniture should only be wiped clean with a soft damp cloth. A non- abrasive mild household detergent may be used to remove ingrained grime.

  • Mortice Lock
    Care should be taken to ensure the internal components are kept free of dirt and woodchips during installation as this is the most common cause of malfunction and will not be covered under warranty. Tubular latches used in external situations should be lubricated by an aerosol lubricant at twelve (12) monthly intervals.

WARRANTY

Our goods come with guarantees that cannot be excluded under the local consumer law. You are entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. The warranty does not cover any defect or damage which may be caused or partly caused if the goods are not properly maintained, installed or are not suitable to the specified application.
Refer to our website for our finish warranty www.allegion.co.nz/finisheswarranty.

SCHLAGE BREEZE APP
For an enhanced experience and additional functionality, we recommend you download the Schlage Breeze mobile app from the Apple App Store or the Google Play Store.

  1. Create a user account using your email address (or login if you have an existing account).
  2. Ensure Bluetooth is enabled on your phone, tap the keypad of your Schlage Omnia lock to activate it.
  3. To pair the lock with the app, click on the + and follow the instructions on the app.

Allegion (Australia) Pty Ltd Freephone 1800 098 094
Email [email protected]
www.allegion.com.au

Allegion (New Zealand) Limited Freephone 0800 477 869
Email [email protected]
www.allegion.co.nz

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Schlage User Manuals

Related Manuals