Eterna CFLEDWHSC 17W LED Ceiling/Wall Fitting Instruction Manual

June 6, 2024
Eterna

Eterna logo

Eterna CFLEDWHSC 17W LED Ceiling/Wall Fitting

Eterna CFLEDWHSC 17W LED CeilingWall Fitting fig1

READ THIS FIRST:

Check the pack and make sure you have all of the parts listed on the front of this booklet. If not, contact the outlet where you bought this product. This product must be installed by a competent person in accordance with the current building and IEE wiring regulations.
As the buyer, installer and/or user of this product it is your own responsibility to ensure that this fitting is fit for the purpose for which you have intended it. Eterna Lighting cannot accept any liability for loss, damage or premature failure resulting from inappropriate use.

This product is designed and constructed according to the principles of the appropriate British Standard and is intended for normal domestic service. Using this fitting in any other environments may result in a shortened working life, for example where there is prolonged periods of use or higher than normal ambient temperatures such as lighting public or shared spaces or in nursing /care home facilities.
Switch off the mains before commencing installation and remove the appropriate circuit fuse or lock off MCB. This product is suitable for use in living areas, and Bathroom Zone 2 and outsides of zones.

If being fitted in a bathroom a 30mA RCD must be used.

Bathroom Zones Diagram

Eterna CFLEDWHSC 17W LED CeilingWall Fitting fig2

This product is designed for permanent connection to fixed wiring: this must be a suitable circuit (protected with the appropriate MCB or fuse). This product is suitable for installation on surfaces with normal flammability e.g. wood, plasterboard and masonry. It is not suitable for use on highly flammable surfaces (e.g. polystyrene, textiles). Before making fixing hole(s), check that there are no obstructions hidden beneath the mounting surface such as pipes or cables.

The chosen location of your new fitting should allow for the product to be securely mounted (e.g. to a ceiling joist) and safely connected to the mains supply (lighting circuit). When making connections ensure that the terminals are tightened securely and that no strands of wire protrude. Check that the terminals are tightened onto the bared conductors and not onto any insulation. This product must be connected to earth termination.

This product is not intended to be used by children and persons with sensory, physical and/or mental impairments that would prevent them from using it safely. You are advised at every stage of your installation to double-check any electrical connections you have made. After you have completed your installation there are electrical tests that should be carried out, these tests are specified in the current IEE wiring and building regulations.

LAMP REPLACEMENT:

The light source is designed to last the lifetime of the luminaire.

The light source contained in this luminaire shall only be replaced by the manufacturer, service agent or a similar qualified person.
CAUTION, RISK OF ELECTRIC SHOCK.

INSTALLATION:

Choose the location for your new fitting according to the conditions listed opposite.

  1.  Hold the base of the fitting and gently turn the diffuser and decorative trim anti-clockwise and lift off.
  2.  Drill holes in the back of your fitting for your fixing screws, take care and drill gently to ensure a clean hole through. Use a drill bit sized appropriately to your fixing screws (not supplied).
  3.  Using the back of your fitting as a template, mark the position of your fixing holes on your mounting surface.
  4. Prepare the holes in your mounting surface as appropriate for your fixings.
  5. Pierce the rubber grommet in the back of your fitting making a hole just large enough to make a tight fit around the incoming mains cable.
  6. Thread the cable through the grommet and offer the fitting to the ceiling / wall.
  7. Secure the fitting in place. Note, if protection against ingress of moisture is required, the heads of screws must be covered with a silicone or similar sealant.
  8. Check that the grommet is still correctly fitted in the cable entry hole and around the incoming cable.
  9.  Make the electrical connections to the gear tray according to the symbols, adjacent to the connector block, Brown to live (L) Blue to neutral (N) and earth green & yellow (E).
  10.  Offer the diffuser and decorative trim onto the top of the fitting and turn clockwise until they are held securely.
  11. Restore the power and switch on.

Eterna CFLEDWHSC 17W LED CeilingWall Fitting fig3

LED LAMP SPECIFICATIONS:

Luminaire lumens (with diffuser)| 1350 lm
Lumens from chip (no diffuser)| 1700 lm
Useful lumens| 1300 lm
Rated Wattage| 17W
Rated luminous flux| 1300 lm
Nominal life time of the lamp| 35,000 hrs
Colour temperature| 4200K
Number of switching cycles before premature lamp failure| ****

15,000

Warm-up time up to 60% of the full light output| Instant full light
Dimmable| No
LED array dimensions| Ø 130mm
Nominal beam angle| 120°
Rated power| 17W
Rated lamp lifetime| 35,000 hrs
Displacement factor|
Lumen maintenance factor at end of nominal life| >0.7
Starting time| <0.1s
Colour rendering| >80
Colour consistency| Within a six step Macadam ellipse
Rated peak intensity| 520cd
Rated beam angle| 120°
Voltage / Frequency| 240V~50Hz
This product contains a Light Source of Energy Efficiency Class F
Not suitable for accent lighting

Eterna CFLEDWHSC 17W LED CeilingWall Fitting fig4

See website for more information on replacability and recycling

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Eterna User Manuals

Related Manuals