IMPORTANT SAFETY MEASURES AND INSTRUCTIONS
WARNING!
- Please read this manual before operating the appliance and keep it in a safe place for future reference. In case the appliance is obtained by a new owner, it should be transferred together with its manual.
- CAUTION: Children under 3 years of age should be kept away from the appliance unless they are under constant supervision. Children from 3 to 8 years of age are allowed to operate the on/off button ONLY, provided that the appliance is installed and ready for operation and such children have been supervised and instructed in the safe operation of the appliance and they understand all related risks. Children from 3 to 8 years of age MUST NOT: connect the plug to power sockets, make adjustments, clean it or carry out user maintenance operations. This appliance can be used by children older than 8 years of age and by people with reduced physical, sensor, and mental capabilities, as well as by people with insufficient experience and knowledge provided they are supervised or instructed in the safe operation of the appliance and understand the related risks. Children should not be allowed to play with the appliance. Cleaning and user maintenance operations must not be carried out by children without supervision.
- CAUTION: Some of the appliance parts may get very hot during operation and thus cause burns to users. In case there are children and vulnerable people in the room, special attention should be paid.
- WARNING: Do not cover the appliance in order to prevent overheating!
- The appliance must not be placed right under a socket box!
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
- Before connecting the appliance to the mains, check if the voltage indicated on its technical plate corresponds to the voltage of the electricity, supplied to your house.
- This appliance shall be used only for the purpose it has been designed and intended for, i.e. heating of domestic premises. The appliance is not intended for commercial/industrial applications. Every other use is to be considered improper, and therefore dangerous. The manufacturer doesn’t bear responsibility for damages arising from improper and irrational use. Non-adherence to these instructions would render the warranty invalid!
- Do not leave your home while the heater is operating: make sure that the power switch is in the OFF position (panel heaters with mechanical control).
- Keep inflammable objects, such as furniture, pillows, bedding, paper, clothes, curtains, etc. at a safe distance of at least 100 cm away from the panel heater.
- Do not operate the appliance in areas of use or storage of combustible substances. Do not operate the appliance in areas of combustible media (for example in close proximity to inflammable gases or aerosols) – there is a great risk of explosion and fire!
- Do not insert and do not allow foreign objects to enter the ventilation openings (inlet and outlet) because this will cause electric shock, fire or will damage the appliance.
- The appliance is not suitable for animal breeding. The panel heater is intended for domestic/indoor operation only.
- When positioning the appliance, do not cover the safety grilles; do not hamper the incoming and outgoing airflow. All objects must be at a safe distance of at least 1 meter away from the appliance front and sides.
- The most common reason for overheating is dust and fluff deposits in the appliance. Clean the ventilation openings on a regular basis with a vacuum cleaner, but before that, it is very important to disconnect the heater from the mains.
- Never touch the appliance with wet or moist hands – there is a risk for your life!
- The power socket should be accessible all the time in order to disconnect the power plug when needed as fast as possible! Never pull the power cord or the appliance itself in order to disconnect it from the mains.
- PAY ATTENTION! Outgoing air gets heated during appliance operation (up to more than 100°С)
- If you decide to stop using an appliance of this kind, it is recommended to make it unusable by cutting its power cord after you have disconnected it from the mains. It is advisable for all possible risks related to the appliance to be secured, especially in relation to children that may play with out-of-use appliances.
- Warning: Do not use this appliance with a programmer, counter, or any other mechanism which could automatically turn on the heater – if the appliance is covered or positioned incorrectly there is a risk of fire.
- Position the power cord in such a way that it does not obstruct the free movement of people and cannot be stepped on! Use only approved extension cords, which are suitable for this appliance, i.e. they have a compliance sign!
- Never move the appliance by pulling its power cord; do not use the power cord for carrying other objects!
- Do not bend the power cord and do not pull it against sharp edges; do not place the power cord on hot surfaces or open fire!
- The scattered UVA light emitted by the device is harmless to the eyes. Looking directly at the UVA light is not recommended.
PACKING
- After unpacking the appliance, check if its contents are intact and if it has not been damaged during transportation! In case damage or incomplete delivery is found, contact your authorized retailer!
- Do not dispose of the original packing box! It could be used for storage and transportation purposes in order to avoid damages during transportation!
- Disposal of packing material should be done in the appropriate way! Children must be prevented from playing with polyethylene bags!
INSTALLATION INSTRUCTIONS
-
This panel heater is designed to be used indoors, and mounted on a wall.
Important: In premises bigger than 45 m 3, it is recommended to use a combination of 2 or more panel heaters. -
Do not position the panel heater under a power socket or electricity connection box.
-
DO NOT install/operate the panel heater:
1. in places where a draught is present, which could influence the control settings;
2. right under a power socket;
3. in “Volume 1” for bathrooms;
4. in “Volume 2” if the control board can be reached by a person who is in a shower or in a bathtub; -
for the wall-mounting of the panel heater, only the wall braces must be used which are delivered together with the appliance. When installing the panel heater, minimum safe distances must be observed
-
– Select position, and then select 3 points, from the suggested dimensions of the position for drilling (from the attached mounting template), then drill with suitable drill bit holes in the marked locations on the wall.
-
Insert plastic dowels into the holes.
-
Screw the screws into the dowels, and let them be submitted at least 5 mm.
-
Attach the unit to the screws.
-
Move slightly to the left of the appliance and then lower them down to make sure that the screws are right at the top of the channels.
Second installation option: -
Place the enclosed mounting template on the box, and drill the holes on the top flap of the box, marked with +, in the direction shown in the figure below.
-
Open the box and place it on the wall as shown in the figure below. Transfer the marked holes to the wall.
BATHROOM OPERATION
-
The panel heater must be installed in accordance with the normal trade practices and in compliance with the national legislation (EU electricity directives and regulations concerning special installations and places of operation including bathrooms, shower cabins HD60364-7-701(IEC 603647-701:2006)).
-
In case this panel heater is to be used in a bathroom or other similar room, the following installation requirements must be observed: the panel heater is with IP24 protection (water drops protection). Hence it can be installed in “Volume 2” (see the diagram below) in order to avoid the risk of the control board (power switch and thermoregulator) being reached by a person who is in a shower or a bathtub. The minimum distance between the appliance and a water source should be not less than 1 meter and it is compulsory for the appliance be wall-mounted! If you do not feel sure about the installation of this panel heater in a bathroom, we recommend you consult a professional electrician.
Note: If the above-mentioned instructions cannot be implemented, it is recommended to install the appliance in “VOLUME 3”. -
In wet premises, the power source must be installed at a height of at least 25 cm above the floor (bathrooms and kitchens).
-
The installation must be equipped with a safety fuse, and the distance between the fuse contacts in disconnected conditions should be at least 3 mm.
Thank you for choosing the CN06 panel heater. This is a product that provides heating in winter depending on the consumers’ needs for comfortable room temperature. If operated and taken care of properly in accordance with these instructions, the appliance will provide you with many years of useful operation.
OPERATION INSTRUCTIONS
- Hold for 1.5 sec ON/OFF button for OFF or ON the heater.
- Step back – push the ON/OFF button until 1 second
- Quick menu/Confirmation – push the Mode button until 1 second
- Full menu – hold the Mode button for over 3 seconds
-
Predefined functions:
Comfort mode ; Eco mode ; Sleep mode
1.1. Comfort mode – with the On/Off option
– allows the user to set the desired temperature when being at home. Once set and the function is switched On, the appliance will keep the same room temperature each time of usage. This temperature is to be set at 23°C by default.
Activation of „Comfort mode“ :
– Push the button “Mode” for 3 sec and select “Comfort mode” by pushing any of the buttons: and confirm with the “Mode” button . After that, you should set the comfort temperature
– by pushing any of the buttons or setting the desired temperature.
Confirm with the “Mode” button .
– The “Comfort” mode is activated.
Deactivation of „Comfort mode“ :
– To deactivate the “Comfort” mode press the “On/Off” button for 1.5 sec. Then the heater turns off. The display will continue showing the set temperature. Or press the “Mode” button to choose a different model.
Visualization on Display in “Comfort” mode settings :
– Set temperature
The display shows “Comfort” on the top and the set temperature
When the convector is in „Heating mode„ , the sign „sun„ appears on the display.
1.2. Eco mode – with the On/Off option – allows the user to set the desired temperature when being out of the home. Once set and the function is switched On, the appliance will keep the same room temperature each time of usage. This temperature will be set at 18°C by default. The user could also set the time when the appliance switches to Comfort mode.
Activation of „Eco„ mode
Push the button “Mode” for 3 sec and select “Eco” mode by pushing any of the buttons : or and confirm with the “Mode” button . After that, you should set the temperature – by pushing any of the buttons or set the desired temperature. Confirm with the “Mode” button .
If you want you can set the clock time:
-Select by pushing any of the buttons: or reach the actual hour time.
Confirm with the “Mode” button .
– The minute icon is flashing and by pushing any of the buttons: or reaching the actual minute time. Confirm with the “Mode” button (range 00.00- 24.00).
When the set time has elapsed, the appliance goes to Comfort mode !
Deactivation of „Eco„ mode
– You can exit “Eco” mode by pushing the “On/Off” button for 1.5 sec. Then the heater turns off. The display will continue showing the set temperature. Or press the “Mode” button to choose a different model.
Visualization on Display in “Eco” mode settings :
– Set temperature
The display shows “Eco” in the top and the set temperature
1.3. Sleep mode with On/Off option – two hours after activation, the convector decreases the set temperature to -3°C under the set temperature in Comfort mode. The user could set the time range for operating in Sleep mode then the appliance switches to Comfort mode. By default: 6 hours.
Activation of „Sleep mode„ Push the button “Mode” for 3 sec and select “Sleep mode” by pushing any of the buttons: or , and confirm with the “Mode” button . If you want you can set the clock time: select by pushing any of the buttons: or , reach actual hour time. Confirm with the “Mode” button. The minute icon is flashing and by ushing any of the buttons: or , reaching actual minute time. Confirm with the “Mode” button (range 00.00-24.00). When the set time has elapsed, the appliance goes to Comfort mode!
Deactivation of “Sleep mode”
Users can exit “Sleep mode” by pushing the “On/Off” button for 1.5 sec. Then the heater turns off. The display will continue showing the set temperature. Or press the “Mode” button to choose a different mode.
Visualization on Display in “Sleep” mode settings :
– Set temperature
The display shows “Sleep” in the top and the set temperature -
Basic modes
“Heating” mode
Start “Heating” mode
When the panel heater is switched off its digital display shows
By pushing the ON/OFF button for 1.5 sec the appliance goes into “Heating” mode . Then the display indicates the mode. The set temperature is indicated on the right. If the room temperature is lower than the set one, the heater will switch automatically on, and a heating sign will appear on the display.
The display shows in the top and the set temperature
Deactivation of “Heating” mode
Users can exit “Heating” mode by pushing the “On/Off” button for 1.5 sec. Then the heater turns off. The display will be showing OFF.
Temperature adjustment By pushing any of the buttons: or the user enters “Temperature adjustment” mode and the user can change the temperature settings in the desired direction. The new settings are saved and the heater goes automatically into “Heating” mode . If any of or buttons get pressed longer than 0.5 sec., the temperature settings will start automatically increase or decrease at a rate of 6 units per second. The range of available temperature settings is from 10 up to 30 degrees.
Delay start function
The delay start function allows the user to set the time at which the convector will switch on and start heating.
Push the “Mode” button for 3 sec and select “Delay Start” by pushing any of the buttons: or confirm with the “Mode” button , user can enter the time and temperature when it will automatically go to “Heating” mode. Initially, a setting of 12 hours is set by default, and by pushing or buttons the user can change the time settings in the desired direction.
After the hour of “delay start” mode is chosen, press the “Mode” button for confirmation. After that set the temperature at which the convector will start operating by pushing any of the buttons: or . Confirm with the “Mode” button . If any of or buttons is held for more than 0.5 seconds, the time and temperature settings start automatically increase or decrease at a rate of 4 units per second. Confirm with the “Mode” button or don’t press any button for 3 seconds.
If the user enters time – 00, this mode will not be implemented. If the “Delay start” mode is already enabled and the user selects the “Delay Start” mode again, it can be changed for the remaining time in both possible directions. You can exit this mode by pushing the “On/Off” button . Then panel heater will go into “Heating” mode. The “Delay start” needs to be set from 0 to 96 hours.
Visualization on Display in “Delay start” settings :
The display shows “Delay start” in the top and the set temperature
Anti-frost mode
If the room temperature falls below 5°C and the panel heater is off, the
heater will turn on automatically in order to prevent freezing of the area.
Indication – in left top corner – only when working the anti-frost mode
Factory settings of the function is ON (switched On).
Activation and deactivation of Anti-frost mode
– If the customer wants to change it – push the “Mode” button for 3 sec and
select “Anti-frost” mode by pushing any of the buttons: or .
Confirm with the “Mode” button and user can push the button to reach ‘’OFF”.
Confirm with the “Mode” button .
To activate the function – push the “Mode” button for 3 sec and select “Anti-
frost” mode by pushing any of the buttons: or . Confirm with the “Mode” button
. It starts blinking and the user has to push a button to each ‘’ON’’.
Confirm with the “Mode” button .
Visualization on Display in “Anti-frost” settings :
“Temperature correction for the sensor” function
Due to the specifics of the temperature profile in some premises, there may be
differences between the temperature shown on the display and the actually
measured temperature in the various locations of the heating appliance in the
room.
See the temperature shown on the display of the appliance
Measure the temperature at a place where the temperature is “comfortable”
enough for you (usually at a height of 60 cm from the floor, in a sitting
position).
If you find a difference within a range of ±4°С, you can set the necessary
correction in the convector’s menu (It is important to note that this function
can be set only after the temperature has become the same all around the room,
and depending on the room type, the minimum required time is 7 hours) by
entering the temperature difference resulting between the value on the display
and the actually measured temperature.
This function is used with the purpose of providing better temperature comfort
and energy saving for the user of the electric convector in the room in which
it is in. A temperature difference greater than ±4 °C from the measured
temperature in a specific location in the room indicates that the room where
you use the convector is not well insulated or the temperature is not the same
all around the room.
Example: a convector in a room on a stone floor – the convector displays
18°С (the set temperature is 22°С), the actually measured temperature (feeling
of reached comfort temperature) is 22°С at a height of 60 cm from the floor –
in this case the convector continues to overheat the room (this is a direct energy loss, but the convector cannot reach the set temperature because it measures the temperature at a low height close to the floor) and it will never switch off. In this case, a temperature correction of +4°С needs to be applied to the sensor, thus the convector will display 22°С and it will start switching off, and eventually, it will maintain the set temperature of 22°С).
The normal status of the function is 0°C by default
If the customer wants to change it – by pushing the “Mode” button for 3 sec
and select “Temperature correction” mode by pushing any of the buttons: or .
Confirm with the “Mode” button – by pushing or button user can reach a
temperature correction in the diapason from ‘’-4°C” up to ‘’+4°C”. Confirm
with the “Mode” button .
If the user wants to see the already set correction, should press the “Mode”
button for 3 sec and select “Temperature correction” mode by pushing any of
the buttons: or . Confirm with the “Mode” button . Users can change it by
pushing a button or giving a new value of correction in the diapason ±4°C.
Confirm with the “Mode” button .
If the factory reset function is used, the temperature correction has to be
set again. The factory setting of its value is 0°C.
Visualization on Display in “Temperature correction” settings :
Function Adaptive start
The adaptive start is a function that predicts and initiates the optimal start
of heating in order to reach the set-point temperature at the desired time;
Test according to user instruction/documentation. The function is tested in a
room with a continuous heat demand of 50 – 60% with reference to the wattage
of the test device. The product is working at a comfortable temperature of
23°C ± 3°C setpoints until stable conditions. This temperature is the
reference comfort temperature “Ct”.
Activate a set-back period of 7h +2h/-0h per 24h with a set-back of 4°C ± 1°C.
The comfort period is 17 -2h/+0h hours. With the adaptive control activated –
let the heater thermostat work during 4 periods (4 x 24 hours) of comfort and
low setback cycles. After the latest low setback period finishes the comfort
temperature “Ct” should be reached within ± 30 minutes deviation from the time
target – with a maximal difference of ± 1⁰C from the reference comfort
temperature “Ct”.
– Factory setting of the function is ‘’ON”
Deactivation of function Adaptive start :
– If the customer wants to change it – by pushing the “Mode” button for 3 sec
and select “Adaptive start” mode by pushing any of the buttons: or. Confirm
with the “Mode” button and user can push the button to reach ‘’OFF”. Confirm
with the “Mode” button. In this case, the function adaptive start is switched
OFF.
Activation of function Adaptive start :
To return again in condition ‘’ON’’ – by pushing the “Mode” button for 3 sec
and select “Adaptive start” mode by pushing any of the buttons: or . Confirm
with the “Mode” button and the user can push the button to reach ‘’ON”.
Confirm with the “Mode” button . In this case the function
The adaptive start is switched ON.
Visualization on Display in “Adaptive start” settings :
RESET to default settings
If the customer wants to reset the convector to factory settings – by pushing
the “Mode” button for 3 sec and select “RESET” mode by pushing any of the
buttons: or . Confirm with the “Mode” button .
Visualization on Display in “RESET” settings :
After using the reset function, the following functions will be re-set:
– clock time
– temperature correction value 0⁰C
– function Anti-frost mode is activated
– adaptive start is activated
– weekly program – 24/7 is reset.
Open window/door function
Room temperature control with open window detection – the product is equipped
with an integrated electronic device that reduces the heat output when
detecting an open window or door. A sensor is used to detect an eventual drop
in the room temperature. If the temperature falls more than 5˚C, the convector
will switch off by itself. Within 15 min the open window detection should turn
the appliance off. When the room temperature rises by at least 0.5°C and the
difference from the initial set point is below 5°C, the convector switches
itself on with the settings already made. If the temperature does not rise for
more than 60 minutes, the convector enters Standby mode. The function is
allowed to be canceled manually.
The function can be switched Off manually.
Deactivation of Open window/door function :
If the customer wants to change it – by pushing the “Mode” button for 3 sec
and select “Open window” mode by pushing any of the buttons: or . Confirm with
“Mode” button . The user has to push the button to reach ‘’OFF”. Confirm with
the “Mode” button . In this case function “Open window” is switched OFF.
Note: When the “Open window” function is enabled, the “Anti-frost”
function does not work!
Visualization on Display in “Open window” settings :
Keyboard lock (Protection from children)
When a user turns on this function, all keys of the control panel remain
locked.
Hold buttons and “Mode” together for 3 seconds. The display should show a
message when this mode is activated. When a user wants to turn off this
function has to hold the same button combination for 3 seconds.
Activation/deactivation: Holding and “Mode” buttons for 3 seconds the keyboard
gets locked.
To unlock the control panel, hold and “Mode” buttons for 3 seconds.
Visualization on Main Display when activating and deactivating the function “Protection from children”:
Day and time – settings
The first step or use after the factory reset function
Set the current time and day by pushing the “Mode” button for 3 sec and select
“DAY TIME” mode by pushing any of the buttons: or . Confirm with the “Mode”
button :
Set a schedule for the first day of the week
Select “DAY OF THE WEEK” mode by pushing any of the buttons: or . Confirm with
“Mode” button .
Select by pushing any of the buttons: or reach the current day of the week
(Monday, Tuesday, Wednesday, Thursday, Friday, Saturday, Sunday).
Confirm with the “Mode” button .
Set time
Select “TIME” mode by pushing any of the buttons: or . Confirm with “Mode”
button .
The hour icon is flashing and by pushing any of the buttons: or reaching the
actual hour time. Confirm with “Mode” button . The minute icon is flashing and
by pushing any of the buttons: or reaching the actual minute time. Confirm
with the “Mode” button . (range 00.00-24.00)
Weekly program (timer) 24hours/7days
Min 300 sets of time periods
Electronic thermoregulator with the weekly program (timer) 24/7 – electronic
room temperature control plus weekly timer means the product is equipped with
an electronic device, either integrated or external, which allows the product
automatically to vary its heat output over a certain time period. In relation
to a certain required level of indoor heating comfort. It allows the setting
of timing and temperature levels for a full week. During the 7-day period the
settings must allow a variation on a day-to-day basis;
Deactivation
If the customer wants to deactivate it, he/she has to push ON/OFF button(The
heater goes into “heating” mode.) or press for 1.5 sec ON/OFF button for OFF
the heater.
Activation
If the customer wants to set “Weekly schedule (timer)” mode- by pushing the
“Mode” button for 3 sec and select “Weekly schedule” ****mode by pushing any
of the buttons: or . Confirm with the “Mode” button .
There have three options:
– CREATE PROGRAM
– ERASE PROGRAM
– VIEW PROGRAM
Create program
Select “Create program” by pushing any of the buttons: or . Confirm with “Mode” button .
- Set “DAY OF THE WEEK” by pushing any of the buttons: or reach the current day of the week (Monday, Tuesday, Wednesday, Thursday, Friday, Saturday, Sunday) . Confirm with the “Mode” button .
- Set “TIME PERIOD” by pushing any of the buttons: or reach the desired Start time (range 00.00-24.00). Confirm with the “Mode” button . By pushing any of the buttons: or reach the desired End time (range 00.00-24.00). Confirm with the “Mode” button .
- Set “DESIRE TEMPERATURE” by pushing any of the buttons: or reach the desired temperature (10-30 ˚C). Confirm with the “Mode” button .
The temperature of 22 ˚C started at 12.30 to 15.00 on Sunday. The convector
will heat till reaches the settings of the next given point.
If the TIME PERIOD is empty (no time set) – visualization should be OFF .
– One step back – with single pushing of the ON/OFF button .
– No limit of time periods – step is 0.5 hours (30 minutes).
– Adaptive start function is switched on by default.
Erase program
Select “Erase program” by pushing any of the buttons: or . Confirm with the
“Mode” button . Select the program by pushing any of the buttons or confirm
with the “Mode” button .
Checking the schedule program
View program
Select “View program” by pushing any of the buttons or . Confirm with the
“Mode” button . Select a day of the week (Monday, Tuesday, Wednesday,
Thursday, Friday, Saturday, and Sunday) by pushing any of the buttons or
confirming with the “Mode” button . You can view the programs for the selected
day by pushing any of the buttons or. One step back – with a single push of
the ON/OFF button.
Function AirSafe – only for models CN 06 xxx EА CLOUD AS W and CN 06 xxx EА AS W
Function Air Safe
The Air safe function Is a result of working together of the module, composed
of UVA LEDs and the convector heater.
Advantages of the function:
- Better air hygiene and a healthier environment, thanks to the bactericidal effect of the function.
- Safe operation, even in the presence of people and animals – the light emitted by the module is UVA, which is 95% of the UV light passing through the atmosphere. The reflected UV light in the volume of the housing in which the heater is located has a very low intensity and energy and has no harmful effects on humans, plants, and animals.
- Without the generation of ozone, hydrogen peroxide, organic or inorganic molecules or ions
- The high degree of reduction of bacteria and fungi
- Extremely long service life – over 50,000 hours (over 12 years).
- Quite working mode – natural airflow, through the convector heater
Principle of work of Air safe function
The Air Safe function can be switched on and off by the user through the
convector control menu. In order to work, it is necessary for the convector to
be switched on and heated (the set temperature is higher than the ambient
temperature).
When the temperature of the heater rises, the natural airflow starts in the
room.
Colder air enters through the lower openings of the convector and passes by
the UVA LEDs.
Due to this movement, the molecules of gases, bacteria, micromycetes (fungi),
and other microorganisms contained in or carried by air are irradiated by the
combined effect of UVA LED radiation and the infrared radiation of the heater.
The continuous passage of the airflow through the volume of the convector
provides enough energy to break the connections supporting the structure of
harmful microorganisms carried by air.
As a result of natural convection, after a certain period of time, the air
contained in the room completely passes through the volume of the convector,
which leads to a reduction of the bacteria and micromycetes contained in it.
Function Air Safe is a protection against harmful organisms such as bacteria
and fungi. Provides better air hygiene and benefits а healthier environment.
The function can be switched Off manually.
If the customer wants to change it- by pushing the “Mode” button for 3 sec and
select “Air Safe” mode by pushing any of the buttons: or . Confirm with the
“Mode” button . The user has to push the button to reach ‘’OFF”. Confirm with
the “Mode” button . In this case, the function is switched OFF.
To return again in condition ‘’ON’’ – by pushing the “Mode” button for 3 sec
and select “Air Safe” mode by pushing any of the buttons: or .Confirm with the
“Mode” button . The user has to push the button to reach ‘’ON”. Confirm with
the “Mode” button . In this case, the function is switched ON.
Operation of Air Safe must continue for 2 minutes after stopping the heating
element, and then turn off.
Built-in tip-over switch – if the convector tilts at more than 45° or falls
down, the power must switch Off and indicate on display ‘’tilt’’. After
restoring the device to its normal position, the operation of the last set
function must continue.
Function Wi-Fi – only for models CN 06 xxx EA CLOUD AS W and CN 06 xxx EA CLOUD W
Function Wi-Fi
If the customer wants to switch off the Wi-Fi function – by pushing the “Mode”
button for 3 sec and select “WI-FI” mode by pushing any of the buttons: or .
Confirm with the “Mode” button . The user has to push the button to reach ‘’
Wi-Fi OFF”. Confirm with the “Mode” button . In this case function, “WI-FI” is
switched OFF.
To return again in condition ‘’Wi-Fi ON’’ – by pushing the “Mode” button for 3
sec and select “WI-FI” mode by pushing any of the buttons: or . Confirm with
the “Mode” button . The user has to push the button to reach ‘’ Wi-Fi ON”.
Confirm with the “Mode” button . In this case function, “WI-FI” is switched
ON.
To turn ‘’Wi-Fi LOCAL’’ on by pushing the “Mode” button for 6 sec and select
“WI-FI” mode by pushing any of the buttons: or . Confirm with the “Mode”
button . The user has to push the button to reach the‘’ Wi-Fi LOCAL”. Confirm
with the “Mode” button . In this case function “WI-FI LOCAL” is switched ON.
Visualization on Display in “Wi-fi” settings :
Work mode of display:
When pressed – backlight intensity – 100%; after 5s – OFF
Sound option
If the customer wants to deactivate the sound function – push the “Mode”
button for 3 sec and select “Sound” mode by pushing any of the buttons: or
confirm with the “Mode” button . To turn off the sound, choose degree 0
through the buttons or . Confirm with the “Mode” button .
- If the customer wants to activate the sound function – push the “Mode” button for 3 sec and select “Sound” mode by pushing any of the buttons: or . Confirm with the “Mode” button . The user can select 5 degrees of sound volume via the buttons or . Confirm with the “Mode” button . In this case, the sound function is turned on at the level you selected.
Visualization on Display in “Sound” settings :
Device info
If the customer wants to view “Device info” – by pushing the “Mode” button for
3 sec and select “Device info” by pushing any of the buttons: or . Confirm
with the “Mode” button .
Visualization on Display in “Device info”
– ID
– MAC address
– Firmware version
Quick menu
Push the “Mode” button to start a quick already configured program. Select by
pushing any of the buttons: or confirm with the “Mode” button . The program
going to start to work.
Content function:
– Comfort
– Eco
– Sleep
– Delay start
– Weekly schedule
Exit from any mode – with a single push of the ON/OFF button .
Errors mode:
If the display shows “t1” or “t2“, this means that the self-diagnostic system
has found a problem with the temperature sensor. “t1” indicates a disconnected
cable at the sensor, while “t2” indicates a short circuit at the sensor. In
this case, the electric convector will be automatically switched off and it
can be switched on again only after the problem has been fixed. The problem
has to be handled by a qualified specialist.
DISCONNECTION FROM THE POWER SUPPLY:
If the electric convector is disconnected from the mains, this will not affect
the set temperature and the mode of operation which has been active prior to
its disconnection. If for example, the convector has been in “Heating” mode,
after it has been disconnected and reconnected to the mains, it will continue
operating in the same model with the same set temperature.
The principle of operation of the electric convector with energy-independent
memory is to store the settings for 120 minutes guaranteed, and up to 180
minutes not guaranteed.
If the time is more than 120 min the appliance goes to Stand by mode.
PROTECTION
- The appliance is equipped with a safety thermal turn-off device, which automatically turns the heater off in cases of the extreme temperature of the panel heater /i.e. overheating of the appliance/.
- The safety thermal turn-off device will automatically restore the heater operation when the temperature of the appliance falls below the permissible ultimate values.
CLEANING
- It is compulsory first to turn off the appliance through its power switch and to disconnect it from the power socket. Before starting the cleaning session you should wait until the panel heater cools down in a disconnected state.
- Clean the heater body with a damp cloth, vacuum cleaner, or brush.
- Never immerse the appliance into the water – there is a danger for your life from electric shock!
- Never use gasoline, thinner, or hard abrasive products to clean the appliance, because they will damage the appliance coating.
STORAGE
- Before putting the panel heater away let it cool down after you have disconnected it from the power socket
- Use the appliance’s original packing to store it, if the panel heater will not be in use for a long period of time. By storing the product in its original packing you protect it from excessive dirt and dust accumulation.
- Never put a hot panel heater in its packing!
- It is necessary the product be stored in a dry and dark place, protected from direct sunlight.
- It is explicitly forbidden to store the panel heater in damp and wet premises.
MAINTENANCE OPERATIONS OF THE APPLIANCE
- In case of appliance malfunction, please contact the authorized service center closest to your location. /service centers are indicated in appliance warranty documents/.
- Important: In case of a claim and/or violation of your consumer rights, please contact the supplier of this appliance at the indicated locations or via the Internet page of the company: www.tesy.com
DIMENSIONS OF HEATED VOLUME AND HEATED AREA OF A ROOM / APPLIANCE MODELS
Model | Heated volume | Heated area |
---|---|---|
CN 06 060 EA [CLOUD] [AS] W – 600W | 10* – 23 m³ | 4* 9 m² |
CN 06 100 EA [CLOUD] [AS] W – 1000W | 24* – 33 m³ | 10* – 13 m² |
CN 06 140 EA [CLOUD] [AS] W – 1400W | 34* 45 m³ | 14* – 18 m² |
CN 06 200 EA [CLOUD] [AS] W – 2000W | 46* – 65 m³ | 19* – 26 m² |
- Minimum guaranteed heated volume (area) for heating at an average capacity of heat transmission factor λ=0.5 W/(m² K) for a heated room. Higher values of heated volume (area) can be achieved at an average value of λ=0.35 W/ (m² K). Standard height of heated rooms – 2.5 meters.
Environment protection instructions
Obsolete electric appliances contain valuable materials and consequently, they
should not be treated as domestic waste! We ask for your cooperation and your
active contribution to protecting the resources and the environment. Please
submit your out-of-use appliances to the organized buy-back stations (if there
are such).
TABLE 2: INFORMATION REQUIREMENTS FOR ELECTRIC LOCAL SPACE HEATERS
Model identifier(s): 1.CN06 060 EAW; 2. CN06 100 EAW; 3. CN06 140 EAW; 4. CN06
200 EAW 230V~ 50Hz
Item | Symbol | Value1 | Value2 | Value3 | Value 4 | Unit | Item | Unit |
---|---|---|---|---|---|---|---|---|
Heat output | Type of heat input for electric storage local space heaters only | |||||||
(select one) | ||||||||
Nominal heat output | Phnom | 0.60 | 1.00 | 1.40 | 2.00 | kW | Manual heat charge | |
control, with integrated thermostat | [no] | |||||||
Minimum heat output (indicative) | Pin | 0.00 | 0.00 | 0.00 | 0.00 | kW | Manual heat | |
charge control, with room and/or outdoor temperature feedback | [no] | |||||||
Maximum continuous heat output (indicative) | Pmax | 0.60 | 1.00 | 1.40 | 2.00 | kW |
Electric heat charge control, with room and/or outdoor temperature feedback
heat charge control, with integrated thermostat| [no]
Auxiliary electricity consumption| Fan-assisted heat output| [no]
At nominal heat output| elmax| 0.57| 0.92| 1.| 2.| kW| Type of heat
output/room temperature control (select one)| –
At minimum heat output| Elgin| 0.00| 0.00| 0.00| 0.00| kW| Single-stage heat
output and no room temperature control| [no]
In standby mode| el SB| 0.0002| kW| Two or more manual stages, no room
temperature control| [no]
| With mechanic thermostat room temperature control| [no]
With electronic room temperature control| [no]
With electronic room temperature control plus a day timer| [no]
With electronic room temperature control plus a week timer| [yes]
Other control options (multiple selections possible)|
Room temperature control, with presence detection| [no]
Room temperature control, with open window detection| [yes]
With the distance control option| [no]
With adaptive start control| [yes]
With working time limitation| [no)
With a black bulb sensor| [no]
Model identifier(s): 1. CN06 060 EA AS W; 2. CN06 100 EA AS W; 3. CN06 140 EA AS W; 4. CN06 200 EA AS W 230V~ 50Hz
Item | Symbol | Value 1 | Value 2 | Value 3 | Value 4 | Unit | Item | Unit |
---|---|---|---|---|---|---|---|---|
Heat output | Type of heat input for electric storage local space heaters | |||||||
only (select one) | ||||||||
Nominal heat output | Phnom | 0.6 | 1 | 1.4 | 2 | kW | Manual heat charge control, | |
with integrated thermostat | [no] | |||||||
Minimum heat output (indicative) | Pin | 0 | 0 | 0 | 0 | kW | Manual heat charge | |
control, with room and/or outdoor temperature feedback | [no] | |||||||
Maximum continuous heat output(indicative) | Pmax, C | 0.6 | 1 | 1.4 | 2 | kW |
Electric heat charge control, with room and/or outdoor temperature feedback
heat charge
control, with an integrated thermostat| [no]
Auxiliary electricity consumption| Fan-assisted heat output| [no]
At nominal heat output| elmax| 0.58| 0.93| 0.93| 1.94| kW| Type of heat
output/room temperature control (select one)| –
At minimum heat output| Elgin| 0| 0| 0| 0| kW| Single-stage heat output and no
room temperature control| [no]
In standby mode| el SB| 0.0002| | kW| Two or more manual stages, no room
temperature control| [no]
| With mechanic thermostat room temperature control| [no]
With electronic room temperature control| [no]
With electronic room temperature control plus a day timer| [no]
With electronic room temperature control plus a week timer| [yes]
Other control options (multiple selections possible)|
Room temperature control, with presence detection| [no]
Room temperature control, with open window detection| [yes]
With the distance control option| [no]
With adaptive start control| [yes]
With working time limitation| [no]
With a black bulb sensor| [no]
TABLE 2: INFORMATION REQUIREMENTS FOR ELECTRIC LOCAL SPACE HEATERS
Model identifier(s): 1. CN06 060 EA CLOUD W; 2. CN06 100 EA CLOUD W; 3.
CN06 140 EA CLOUD W; 4. CN06 200 EA CLOUD W 230V~ 50Hz
Item| Symbol| Value 1| Value 2| Value 3| Value
4| Unit| Item| Unit
---|---|---|---|---|---|---|---|---
Heat output| Type of heat input for electric storage local space heaters only
(select one)|
Nominal heat output| Phnom| 0.6| 1| 1.4| 2| kW| Manual heat charge control,
with integrated thermostat| [no]
Minimum heat output (indicative)| Pin| 0| 0| 0| 0| kW| Manual heat charge
control, with room and/or outdoor temperature feedback| [no]
Maximum continuous heat output
(indicative)| Pmax, C| 0.6| 1| 1.4| 2| kW| Electric heat charge control, with
room and/or outdoor temperature feedback heat charge
control, with an integrated thermostat| [no]
Auxiliary electricity consumption| Fan-assisted heat output| [no]
At nominal heat output| elmax| 0.57| 0.92| 1.32| 1.93| kW| Type of heat
output/room temperature control (select one)| –
At minimum heat output| Elgin| 0| 0| 0| 0| kW| Single-stage heat output and no
room temperature control| [no]
In standby mode| el SB| 0.00054| | kW| Two or more manual stages, no room
temperature control| [no]
| With mechanic thermostat room temperature control| [no]
With electronic room temperature control| [no]
With electronic room temperature control plus a day timer| [no]
With electronic room temperature control plus a week timer| [yes]
Other control options (multiple selections possible)|
Room temperature control, with presence detection| [no]
Room temperature control, with open window detection| [yes]
With the distance control option| [yes]
With adaptive start control| [yes]
With working time limitation| [no]
With a black bulb sensor| [no]
Model identifier(s): 1. CN06 060 EA CLOUD AS W; 2. CN06 100 EA CLOUD AS W; 3. CN06 140 EA CLOUD AS W; 4. CN06 200 EA CLOUD AS W 230V~ 50Hz
Item| Symbol| Value 1| Value 2| Value 3| Value
4| Unit| Item| Unit
---|---|---|---|---|---|---|---|---
Heat output| Type of heat input for electric storage local space heaters only
(select one)|
Nominal heat output| Phnom| 0.6| 1| 1.4| 2| kW| Manual heat charge control,
with integrated thermostat| [no]
Minimum heat output (indicative)| Pin| 0| 0| 0| 0| kW| Manual heat charge
control, with room and/or outdoor temperature feedback| [no]
Maximum continuous heat output
(indicative)| Pmax, C| 0.6| 1| 1.4| 2| kW| Electric heat charge control, with
room and/or outdoor temperature feedback heat charge
control, with an integrated thermostat| [no]
Auxiliary electricity consumption| Fan-assisted heat output| [no]
At nominal heat output| elmax| 0.58| 0.94| 1.34| 1.96| kW| Type of heat
output/room temperature control (select one)| –
At minimum heat output| Elgin| 0| 0| 0| 0| kW| Single-stage heat output and no
room temperature control| [no]
In standby mode| el SB| 0.00054| kW| Two or more manual stages, no room
temperature control| [no]
| With mechanic thermostat room temperature control| [no]
With electronic room temperature control| [no]
With electronic room temperature control plus day timer| [no]
With electronic room temperature control plus a week timer| [yes]
Other control options (multiple selections possible)|
Room temperature control, with presence detection| [no]
Room temperature control, with open window detection| [yes]
With the distance control option| [yes]
With adaptive start control| [yes]
With working time limitation| [no]
With a black bulb sensor| [no]
TROUBLESHOOTING
Prior to contacting the Customer Service Center, please check the items in the table below.
PROBLEM | CAUSE | SOLUTION |
---|---|---|
The appliance doesn‘t work | No power supply from the grid. |
Be sure that the product is plugged in and that the electrical
the outlet is working.| Plug into the power outlet and check the position of
the ON/OFF
switch.
The temperature may be set too low.| Set the temperature to a higher position.
The “Protection from children” may be activated.| See the section “Protection
from children” in the user manual.
The delayed start is working.| Press the Turn ON button from the control
board.
The room does not get warm enough although the appliance is hot
`| Appliance overheating. High limit safety cut-out limits heating output.|
Eliminate the cause (cover, dirt, or obstructions at the air inlet or
outlet). Observe minimum clearances according to mounting
instructions.
Check the Temperature correction for the sensor| See the temperature shown on
the display of the appliance.
Measure the temperature at a place where the temperature is
“comfortable” enough for you. If you find a difference within
a range of ±4°С, you can set the necessary correction in the
convector’s menu by entering the temperature difference
resulting between the value on the display and the actually
measured temperature.
The heat demand of the room is higher than the appliance
output.| Remove heat losses (Close windows and doors. Avoid constant
venting.)
Check if the power of your device is adapted to the size of your room.|
Recommended an average of 100 W/m2 for a ceiling height of
2,50m or 30W/m3
Open window/door detection does not respond| The appliance does not detect a
pronounced temperature drop due to venting. (Open window/door detection
requires previously stable room temperature.)| Avoid obstructions that may
prevent normal air exchange
between the appliance and the indoor air.
Open window/door detection is not enabled| Switch on open window/door
detection.
The „Adaptive start“ function does not work as required| This function works
only in weekly mode.| Switch on the Adaptive start function.
Severely fluctuating room temperature or the appliance learning procedure has
not been completed.| Wait a few days for a behavior to stabilize.
The “Adaptive start” function is not enabled.| Switch on the „Adaptive start“
function in the menu.
The display shows “t1” or “t2“| The self-diagnostic system has found a problem
with the
temperature sensor
“t1” indicates a disconnected cable at the sensor
“t2” indicates a short circuit at the sensor| In this case, the electric
convector will be automatically switched
off and it can be switched on again only after the problem has
been fixed by the authorized service representatives.
Contact the authorized service center or the retailer you bought
the product from.
Dirty marks appear on the wall around the device| The dirty marks come as a
result of air contamination.| Make sure that some fresh air enters the room
regularly,
especially if it is used for smoking.
The device does not follow internal
programming commands| The date and time are not set correctly.| Check the set
date and time.
The appliance is under Open window/door detection.| Switch off the Open
window/door detection.
Sounds/Noises| Emitting faint noises during the heating process and shortly
after the set temperature is reached, is not something unusual.| Such effect
is in the result of the natural materials expansions during the rapid
temperature increase and following cooling of the
metals used for product manufacturing.
Yellowish stains on the grid| Such stains could be in result of covering the
product with wet clothes.| Do not cover the product! Such actions are not
allowed, because
they block the air convection and will damage the product
irreparably, leading to serious risk for your health and properties.
TESY Ltd – Head office
1166 Sofia, Sofia Park,
Building 16V, 2nd Floor
PHONE: +359 2 902 6666,
FAX: +359 2 902 6660,
office@tesy.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>