UBIQUITI USW-16-POE UniFi Switch
Package Contents
UniFi Switch
|
Rack-Mount Brackets (Qty. 2)
|
Bracket Screws (Qty. 8)
---|---|---
Mounting Screws (Qty. 4)
|
Cage Nuts (Qty. 4)
|
Power Cord
System Requirements
- Linux, Mac OS X, or Microsoft Windows 7/8/10
- Java Runtime Environment 1.6 (1.8 or newer recommended)
- Web Browser: Google Chrome (Other browsers may have limited functionality.)
- UniFi Controller software v5.11.x (or newer), available at: ui.com/download/unifi
IMPORTANT: We strongly recommend using UPS backup and power regulation to prevent equipment damage due to stability issues with local AC power.
Hardware Overview
❶ Touchscreen Display
Bootup Animation| Initializing.
Steady White| Factory defaults, waiting for adoption.
Steady Blue| Successfully adopted by a network and working
Location Animation| This indicates that you clicked Locate in the UniFi
Controller software. The software will also display the location of the device
on the map.
❷ RJ45 PoE LED (Ports 1 – 8)
Off| No PoE
Amber| 802.3af/at PoE
❸ RJ45 Speed/Link/Activity LED (Ports 1 – 16)
Off| No Link
Amber| Link Established at 10/100 Mbps Flashing Indicates Activity
Green| Link Established at 1000 Mbps Flashing Indicates Activity
❹ SFP Speed/Link/Activity LED (Ports 17 – 18)
Off| No Link
Green
| Link Established at 1 Gbps Flashing Indicates Activity
❺ RJ45 (Ports 1 – 8)
RJ45 ports support 10/100/1000 Ethernet connections and 802.3af/at PoE output.
❻ RJ45 (Ports 9 – 16)
RJ45 ports support 10/100/1000 Ethernet connections.
❼ SFP (Ports 17 – 18)
Hot-swappable SFP ports support 1 Gbps connections.
❽ Reset Button
This button serves two functions for the UniFi Switch: Restart Press and
release the Reset button quickly.
Restore to Factory Default Settings Press and hold the Reset button for more
than five seconds.
❾ Power Port
Installation Requirements
- Phillips screwdriver
- Standard-sized, 19″ wide rack with a minimum of 1U height available
- For indoor applications, use Category 5 (or above) UTP cabling approved for indoor use.
- For outdoor applications, shielded Category 5 (or above) cabling should be used for all wired Ethernet connections and should be grounded through the AC ground of the power supply. We recommend that you protect your networks from harmful outdoor environments and destructive ESD events with industrial-grade, shielded Ethernet cable from
| Note: Although the cabling can be located outdoors, the UniFi Switch
itself should be housed inside a protective enclosure.
---|---
Hardware Installation
IMPORTANT: Fanless switches must not be stacked. Do not place this UniFi Switch on top of another switch. Do not place anything on top of this UniFi Switch.
Connecting Power
Connecting Ethernet
| Note: If you are connecting PoE devices, check the display to see how
much PoE wattage is available.
---|---
Connecting SFP
For information about compatible fiber SFP modules, visit: ubnt.link/UniFi_SFP_DAC_Compatibility
Software Installation
Download and install the latest version of the UniFi Controller software at ui.com/download/unifi and follow the on- screen instructions.
| Note: If you already have UniFi Controller v5.11.x or newer installed,
skip to “Adopting the UniFi Switch”.
---|---
After you have installed the software and run the UniFi Installation Wizard, a login screen will appear for the UniFi Controller management interface. Enter the admin name and password that you created and click Sign In.
You can manage your network and view network statistics using the UniFi
Controller management interface.
To adopt the UniFi Switch, proceed to “Adopting the UniFi Switch”.
For information on configuring and using the UniFi Controller software, refer
to the User Guide on the website:
ui.com/download/unifi
Adopting the UniFi Switch
-
From the UniFi Controller dashboard, click Devices in the left menu bar.
-
On the Devices screen, locate the UniFi Switch in the list of devices under the Model column. To adopt the UniFi Switch, click Adopt.
Specifications
USW-16-POE
Dimensions| 442.4 x 200 x 43.7 mm (17.42 x 7.87 x 1.72″)
Weight
With Rackmount Brackets| 2.80 kg (6.17 lb)
2.89 kg (6.37 lb)
Interfaces Networking
Management| (16) 10/100/1000 RJ45 Ports
(2) 1G SFP Ethernet Ports
Ethernet In-Band
Power Method| 100-240VAC/50-60 Hz, Universal Input
Power Supply| AC/DC, Internal, 60W
Supported Voltage Range| 100 to 240VAC
Max. Power Consumption (Excluding PoE Output)| 18W
LEDs
System
RJ45 Data Ports SFP Data Ports| Status
PoE; Speed/Link/Activity
Link/Activity
ESD/EMP Protection| Air: ± 16 kV, Contact: ± 12 kV
Shock and Vibration| ETSI300-019-1.4 Standard
Operating Temperature| -5 to 40° C (23 to 104° F)
Operating Humidity| 10 to 90% Noncondensing
Certifications| CE, FCC, IC
PoE
PoE Interfaces Ports 1-8| POE+ IEEE 802.3af/at (pins 1, 2+; 3, 6-)
Max. PoE Wattage per Port by PSE 802.3at| 32W
Voltage Range 802.3af Mode| 44-57V
Voltage Range 802.3at Mode| 50-57V
Safety Notices
- Read, follow, and keep these instructions.
- Heed all warnings.
- Only use attachments/accessories specified by the manufacturer.
| WARNING: Failure to provide proper ventilation may cause fire hazard.
Keep at least 20 mm of clearance next to the ventilation holes for adequate
airflow.
---|---
| WARNING: To reduce the risk of fire or electric shock, do not expose
this product to rain or moisture.
| WARNING: Do not use this product in location that can be submerged by
water.
| WARNING: Avoid using this product during an electrical storm. There may
be a remote risk of electric shock from lightning.
Electrical Safety Information
- Result in improper operation, damage to the equipment or pose a fire hazard if the limitations are not followed.
- There are no operator serviceable parts inside this equipment. Service should be provided only by a qualified service technician.
- This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet.
a. Do not substitute the power cord with one that is not the provided approved type. Never use an adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding wire.
b. The equipment requires the use of the ground wire as a part of the safety certification, modification or misuse can provide a shock hazard that can result in serious injury or death.
c. Contact a qualified electrician or the manufacturer if there are questions about the installation prior to connecting the equipment.
d. Protective earthing is provided by Listed AC adapter. Building installation shall provide appropriate short-circuit backup protection.
e. Protective bonding must be installed in accordance with local national wiring rules and regulations.
Limited Warranty
ui.com/support/warranty
The limited warranty requires the use of arbitration to resolve disputes on an
individual basis, and, where applicable, specify arbitration instead of jury
trials or class actions.
Compliance
FCC
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions.
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
ISED Canada
CAN ICES-3(A)/NMB-3(A)
Australia and New Zealand
| Warning: This equipment is compliant with Class A of CISPR 32. In a
residential environment this equipment may cause radio interference.
---|---