CAMRY 821-027 Kitchen Scales Instruction Manual

June 6, 2024
camry

CAMRY 821-027 Kitchen Scales

CAMRY 821-027 Kitchen Scales FIG 1SAFETY INFORMATION

Read the operating instructions carefully before use. Please retain for future reference.

DESCRIPTION

FEATURES

LCD display in the picture is for reference only. Use trial and error with the correct product.

  • Indicate volume of water and milk
  • wo weight unit systems gA lb:oz convertible
  • Two volume unit systems ml, fl’oz convertible
  • Low battery power/ Overload indication
  • With high precision strain gauge sensor
  • With tare function
  • Auto-off
TO INSTALL OR REPLACE BATTERIES

1x 3 V CR2032 lithium batteries (included). Remove isolation sheet before use.

  • Open the battery case cover at the bottom of the scale.
  • Take out the used battery with the aid of a sharp object, as shown.
  • Install new battery by putting one side of the battery beneath the battery baffle (1) and then pressing down the other side.
LCD SCREEN

CAMRY 821-027 Kitchen Scales FIG 3

  1. Tare
  2. Negative value
  3. Zero
  4. Working mode weight
  5. Working mode milk
  6. Working mode water
  7. Weight unit (lb: oz)
  8. A volume unit (fl’oz)
  9. A volume unit (ml)
  10. Weight unit (g)
WORKING MODES

CAMRY 821-027 Kitchen Scales FIG 4

OPERATION

**TO START WEIGHING

CAMRY 821-027 Kitchen Scales FIG
5**

Weight mode

  • Place the scale on a solid and flat surface.
  • Place bowl (if used) on the scale before turning on the scale.
  • Gently press on the scale with your hand to turn it on.
  • Wait until LCD shows all information.
  • Put the load on the scale. LCD will show the weight reading.
  • If the weighing object is water or milk, press the MODE button to choose volume mode and view the volume of the object.

Volume indication modeCAMRY 821-027 Kitchen Scales FIG
6

  • Place the scale on a solid and flat surface.
  • Gently press on the scale with your hand to turn it on.
  • Wait until the LCD shows “o”, then press the MODE button to choose “Water” or “Milk” mode. Put a liquid container on the scale platform.
  • Press the ZERO button to reset LCD to “o”.
  • Pour the liquid (water or milk) into the container. The LCD shows the volume of the liquid.
  • Press the MODE button to choose “Weight” mode and view the weight of the liquid.

ZERO AND TARE FUNCTIONS

You can weigh different loads consecutively without removing loads from the scale. Put your first load on the scale; get the weight reading. Next, press the ZERO button to zero the scale. Make sure that
“o” appears on the LCD before placing the next item you want to weigh on the scale. You can repeat this operation if necessary.

  • Condition 1: Zero functions
    When total sum of all loads on the scale::;4 % of the scale’s max. weight capacity. (4% = 80 g when weight capacity is 2000 g or 200 g when the weight capacity is 5000 g)
    The LCD will show “—–” or “o g” each time the ZERO button is pressed. Wait a moment if “—–” appears on the display. “o g” and an “o” icon at the same time in the corner of the LCD mean the “Zero” function is activated. Max. weight capacity remains unchanged.

  • Condition 2: Tare functionCAMRY 821-027 Kitchen Scales FIG 8
    When the total sum of all loads on the scale> 4 % of the scale’s max. weight capacity. (4 % = 80 g when the weight capacity is 2000 g or 200 g when the weight capacity is 5000 g)
    The LCD will show “—–” or “o g” each time the ZERO button is pressed. Wait a moment if “—–” appears on the display. “o g” and a (T) icon (tare) at the same time on the upper left corner of the LCD mean the “Tare” function is activated. Max. weight capacity is reduced by the total weight of all loads.

  • Under this condition:
    By pressing ZERO, you can see the total weight of all loads on the scale. If you want to weigh more loads, just press ZERO to reset the LCD reading to ‘o’ again.

AUTO SHUT OFF

Auto shut-off occurs if the display shows ‘o’ or shows the same weight reading for one minute.

WARNING INDICATORS

  • Replace battery.
  • Scale overload. Remove the object to avoid damage to the scale. The max. weight capacity is specified on the scale.

MAINTENANCE

  • Clean the scale with a damp cloth. Do not immerse the scale in water or use chemical/abrasive cleaning agents.
  • All plastic parts should be cleaned immediately after contact with fats, spices, vinegar, or strongly flavored/colored foods. Avoid contact with acidic citrus juices.
  • Always use the scale on a hard, flat surface. Do not use on carpet.
  • Do not hit, shake or drop the scale.
  • The scale is a high-precision device. Please take care of it.
  • Please keep it dry.
  • If the scale cannot be turned on, check that the battery is correctly installed and that it doesn’t need to be replaced.
  • The scale is for household use only, not for commercial purposes.