MYPV 3697 Photovoltaic Water Heater User Manual
- June 6, 2024
- MYPV
Table of Contents
- MYPV 3697 Photovoltaic Water Heater User Manual
- Intended Use
- Scope of Supply
- Safety Instructions
- Exemption of Warranty and Liability
- Assembly and Installation Instructions
- Never tighten the heating rod by turning the metal case of the device!
- Electrical Connection
- Electrical Connection Stratification Charge
- Controls and Indicators
- Operating Status Indicator
- Start-up
- Normal operation with boost backup (AC plug connected)
- Adjusting the boost backup target temperature (factory preset to 50 °C)
- Stratification Charge with two ELWAs
- Error Displays
- Maintenance
- Troubleshooting
- Disposal
- EU Declaration of Conformity
- Technical Data
- General Data
- Read More About This Manual & Download PDF:
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
MYPV 3697 Photovoltaic Water Heater User Manual
Intended Use
The electric hot water device ELWA is designed to be used with photovoltaic
arrays up to 2.5 kWp nominal power.
ELWA should be mounted on conventional hot water tanks or storage tanks with a
minimum capacity of about 150 litres.
The device does not feed any power to the grid. A permission of the grid
operator or the utility is NOT required.
Any use different from that described above may lead to damage and can even
cause short circuits, electric shocks or fire. Safety instructions of this
manual must be followed strictly!
The device fulfils national and European regulations. Company and product name
are trademarks of my-PV GmbH. All rights reserved.
Scope of Supply
- Photovoltaic Water Heater ELWA
- IP21 Cover
- 1 set MC4 Connectors
- Assembly- and Operation Manual
Safety Instructions
Always comply with local regulations for mounting and connection. Any damage caused by ignoring the installation and user manual is not covered by the manufacturer´s warranty. Permanent equipotential bonding of the device and the storage tank is mandatory. Never switch on the device if the heating rod is not fully immersed. The device is intended for use in a dry environment, the enclosure must not get wet or moist. Danger of electric shock! Never use the device where ammonia is present.
Never use the device in a dusty environment.
Never cover the ventilation holes of the enclosure.
Always mind the mounting position: heating rod horizontal, power cord bottom
Avoid high (>40°C) and low (<5°C) ambient temperatures during storage and
operation of the device. Avoid direct sunlight.
Never exceed the maximum DC input voltage (360V).
The thermal fuse blows at approx. 100°C and deactivates the device
permanently.
Caution when using in unpressurized tanks!
AC supply must be fused 10 to 16A. In commercial facilities electrical
installations have to comply with all local regulations.
Exemption of Warranty and Liability
Any warranty or liability is exempted for:
- Injury to persons and/or damage to property caused by unintended use or in disregard of safety- and user instructions
- Consequential damage
- Unauthorized modification, disassembling or other conversion of the device
- Damage caused by calcium deposits on heating element.
- Damage caused by corrosion at heating element.
Assembly and Installation Instructions
The installation of the device must only be carried out by authorized
technical staff. The storage tank must be drained properly.
ELWA is intended for horizontal mounting in hot water or storage tanks with 1
½ inch standard female threads.
The unheated section of the heating rod is 100mm from sealing face, the length
of the thread pipe must not exceed 90mm.
Use the pre-assembled O-ring seal supplied. Do not use any grease or
lubrication agents. The plastic thread must not be sealed with the help of
hemp or other sealing material.
If an adapter flange is used on the tank, we recommend a flange plate made of
stainless steel or at least of an enamelled material. Otherwise corrosion
could occur on the heating elements, but this is excluded from the warranty.
Do not apply force when screwing in the entire device until the seal is
slightly pressed. Make sure that the O-ring is properly placed in its groove.
Then tighten the heating rod with a 60mm spanner. Never exceed a torque of 50
Nm.
Never tighten the heating rod by turning the metal case of the device!
If the device is not upright (power cord bottom) after the thread has been
tightened, it can be turned gently left or right.
Then tighten the 4 lock nuts to fix the device:
Make sure that the heating rod is fully immersed when filling the water tank. Check for leakage.
Electrical Connection
-
Earth (ground) the storage tank according to local regulations.
-
Connect Earth (ground) wire to the grounding screw of the device with a minimum wire section of 1.5mm² (AWG15). Test the ground conductor resistance according to the local regulations (Protection Class 1):
-
Make sure that the device is switched off.
-
Connect MC4 DC wires with correct polarity. Wrong polarity does not cause any damage, but the device will not work.
-
Connect AC plug if boost backup heating is desired.
Electrical Connection Stratification Charge
-
Earth (ground) the storage tank according to local regulations.
-
Connect Earth (ground) wire to the grounding screws of both devices with a minimum wire section of 1.5mm² (AWG15). Test the ground conductor resistance according to the local regulations (Protection Class 1) (see above).
-
Make sure that both devices are switched off.
-
Connect DC wires as shown below:
-
Connect MC4 DC wires with correct polarity. Wrong polarity does not cause any damage, but the device will not work.
-
Connect AC plug of the upper ELWA if boost backup heating is desired.
Controls and Indicators
Main switch
Rotary knob for temperature adjustment
LED green Target temperature reached
LED yellow Normal operation
LED red Error
Rotary knob and indicators
Operating Status Indicator
Start-up
Normal operation without boost backup (AC plug not connected)
Remark: It takes several minutes to start-up ELWA after connecting the DC. The green LED flashes (Standby).
- Adjust desired solar target temperature
- Switch on main switch (Device starts operating several minutes after the DC has been connected and solar power is available)
- Device returns to normal operation LED yellow on
- If target temperature reached Device switches off, LED green on
Normal operation with boost backup (AC plug connected)
Boost backup ensures reaching the AC target temperature in the afternoon independently of sun power.
This function is designed for the additional heating of the hot water
during summer for private applications. For commercial use, especially year- round operation, please contact my-PV.
AC target temperature is factory preset to 50°C. See next chapter to change.
The next boost backup cycle starts in the afternoon of the next day. If a
manual reheat is required (e.g. in the evening), simply switch the device off
and on again. This activates the boost backup cycle.
Remark: If you first connect DC it takes several minutes to start-up the
device (LED green flashing)
- Set rotary knob to desired solar target temperature
- Switch on main switch (Device starts operating several minutes after the DC has been connected and solar power is available)
- Device returns to normal operation LED yellow on if solar powered, LED yellow flashes if backup powered
- If target temperature reached Device switches off, LED green on
Adjusting the boost backup target temperature (factory preset to 50 °C)
- Switch off main switch
- Adjust rotary knop to „spanner“ position (far left)
- Switch on main switch all 3 LEDs flash (Setup Mode)
- Set rotary knob to desired reheat temperature LEDs flash alternately red/green and yellow
- Switch off main switch backup temperature is saved
- Set rotary knob to desired solar target temperature
- Switch on main switch Device returns to normal operation
Stratification Charge with two ELWAs
ELWA is factory preset to operate as a single device or as an upper device in
stratification charge mode.
The lower ELWA has to be set as follows:
- Switch off main switch
- Adjust rotary knop to „spanner“ position (far left)
- Switch on main switch all 3 LEDs flash (Setup Mode)
- Adjust rotary knop to position LEDs run from top to bottom
- Switch off main switch Setting is saved
- Set rotary knob to desired solar target temperature
- Switch on main switch Device is in standby mode (green LED flashing) until activated by upper device
This setting can be reversed by following the above procedure by setting to symbol.
Error Displays
The red LED indicates different error conditions by flashing:
1x flash Over temperature fuse blown. Call your installer for service.
2x flash Water temperature above 90°C. Device stops and will restart heating
when the temperature has fallen. Note: The water temperature is close to the
over temperature fuse threshold. IF the water has been heated by external heat
sources, adjust the maximum temperature threshold of this source to 90°C.
3x flash Electronic circuit over temperature. Device switches off and
restarts after cool-down.
4x flash Error of the electronic circuit or the heating rod. Call your
installer for service.
5x flash DC isolation fault (either solar array or heating rod). Call your
installer for service.
6x flash Temperature sensor fault. Call your installer for service.
Maintenance
Use in limy water can lead to lime scale deposition at the heating rod especially of the target temperature is set above 60°C. We recommend an annual check. Dismantle device from storage tank and remove lime deposition. Never scratch the heating rod surface (corrosion might arise).
Troubleshooting
The device does not contain any user serviceable parts. Call your installer for service.
Disposal
Keep packaging box or dispose properly. Dispose the device according to legal regulations at the end of lifetime.
EU Declaration of Conformity
You can find them at any time on www.my-pv.com
Technical Data
General Data
|
---|---
Operating pressure| max. 10 bar (1MPa)
Overall efficiency| >99% at nominal power
Protection class| IP20 (IP21 with Cover)
Operating temperature range| 5 °C to 40 °C
Operating display| 3 LED’s
Interface| Serial IR Interface
Dimensions (WxHxD)| 130 x 180 x 600 mm incl. heating rod
Heating rod length| 45 cm
Heating rod thread| 1 ½ inch
Weight| 2 kg with power cord, without carton
my-PV GmbH Teichstrasse 43, 4523 Neuzeug www.my-pv.com
Read More About This Manual & Download PDF:
References
- my-PV – Hot Water and Heating with Your Solar Power
- my-PV – Hot Water and Heating with Your Solar Power
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>