K M 11905 Protective Shield Instruction Manual

October 27, 2023
K M

K M Logo 11905 Protective shield
11905 with standK M 11905 Protective Shield

INTENDED USE

  • The protective clear acrylic shield separates –
  • protects and keeps distance.
  • The mobile stand supports and arranges the acrylic
  • shield so that is can be used for many purposes.
  • It is particularly designed for choirs and orchestras.

FEATURES and CAPABILITIES

  • The 600 x 600 x 4 mm acrylic shield is as clear as glass,
  • yet lighter and more resistant
  • Thanks to the proven König & Meyer prismatic connection
  •  it can be easily and quickly separated from the stand.
  • The solid stand is compact foldable for transport.
  • Stepless height adjustment:
  • 11000 – 1600 mm (upper edge of the shield)
  • Weight: 4 kg

Thank you for choosing this product. Please read and follow these instructions carefully. They inform you about all necessary and important steps concerning safe installation and operation. We recommend that you keep them for future reference.

SAFETY INSTRUCTIONS

  • Before and after using the product, please carry out a visual
  • inspection and check for completeness, mobility and possible
  • damage.
  • If the product is damaged, it must not be used or only after a
  • qualified repair.
  • Due to its transparency, the acrylic glass can be easily
  • overlooked and consequently nudged.
  • Careful and cautious handling preserves the function,
  • longevity and, last but not least, safety.
  • Pay attention to the tightness of the screw connections.
  • The facility to adjust the product has hidden hazards and
  • therefore requires careful handling.
  • Protect from adverse influences (moisture, wind, shocks).

SET-UP/OPERATING INSTRUCTIONS

1. COMPONENTS
Please visually check that all parts are present and in good order – as far as recognizable.
a.1 PROTECTIVE SHIELD, consisting of:
a.1 – acrylic shield 600 x 600 x 4 mm
a.2 – receptacle-plug-in connection
b.1 STAND cpl., consisting of:
b.1 – foldable stand base frame
b.2 – base tube
b.3 – clamp
b.4 – extension tube
b.5 – swivel joint K M 11905 Protective Shield - Fig

2. /3. /4. STAND
2. BASE
2.1 Expand legs,
2.2 loosen base screw,
2.3 pull out base tube…
2.4 …up to the stop
2.5 retighten base screw.

TUBE COMBINATION

3.1 Slightly loosen knurled screw of the clamp
3.2 Bring extension tube to the desired height
3.3 Retighten knurled screw

SWIVEL JOINT

4.1 Loosen wing nut
4.2 Vertically (90°) align the joint and the plug-in plate
4.3 Retighten wing nut

FITTING THE PROTECTIVE SHIELD

5.1 Please ensure that the thread of the knurled screw
5.1 on the swivel joint b.5 does not protrude.
5.2 Fit the Protective shield a to the joint by pushing
5.2 the holder a.2 as far as it will go onto the plug-in
5.2 plate of the swivel joint b.5
5.3 Tighten the knurled screw thereby securely fixing the
5.3 Protective shield. To remove the shield loosen the knurled
5.3 screw again. K M 11905 Protective Shield - Fig 1K M 11905
Protective Shield - Fig 2

6. / 7. / 8. / 9./ 10. ADJUSTMENTS and
DIMENSIONS

ALIGNMENT

6.1 Hold the protective shield sideways…
6.2 …and turn in the desired direction, whereby
6.2 there is no need to loosen the clamp.
6.3 The stand remains unchanged.

HEIGHT

K M 11905 Protective Shield - Fig 37.1 Hold the extension,
7.2 slightly loosen knurled screw of the clamp,
7.3 retract or extend the extension as desired,
7.4 retighten knurled screw.

ANGLE OF INCLINATION

8.1 Whilst holding the acrylic shield,
8.2 loosen wing nut on the swivel joint,
8.3 incline the shield as desired,
8.4 retighten wing nut.
POSITION
9.1 Carry the complete stand and place in
9.1 desired location
9.2 NOTE!
9.2 Normally the feet don’t fold by themselves.
9.2 If they do, we recommend that you tighten
9.2 the corresponding Allen screws.
10. DIMENSIONS

MAINTENANCE, CLEANING

  • Special maintenance intervals are not required
  • It is advisable to regularly check the strength and
  • mobility of the components, especially the screw
  • connections, these should be tight, but not too tight.
  • For cleaning, use a slightly damp cloth and a non-
  • abrasive cleaning agent

FAULT-FINDING (F) and REPAIR (R)
F: Installation wobbles.
F: B: Check flooring (especially evenness).
F: B: Check if the parts (parquet protector,
F: B: base, clamp, swivel joint, shield holder)
F: B: are complete, correctly arranged and
F: B: the threads firmly tightened.

POSITION

K M 11905 Protective Shield - Fig 4

DIMENSIONS

K M 11905 Protective Shield - Fig 5

TECHNICAL DATA

Material| Tubes, U-pivot joint:
– steel, powder-coated black Screws, washers:
– galvanised steel,Base, mushroom, receptacle plug-in onnector:
– zinc-GD, powder-coated, black Small plastic parts:
– PA, PE, black Protective shield:
– PMMA, transparent
---|---
Dimensions| Screen: W x H: 600 x 600 mm, thickness: 4 mm
Height: 1000 – 1600 mm (top edge)
Base: ø 690 mm
Cardboard| Package 1: 653 x 653 x 30 mm (acrylic shield)
Package 2: 730 x 125 x 77 mm (stand)
Weight| 4 kg
Accessories (optional)| e.g., tray 12218 ff

KÖNIG & MEYER GmbH & Co. KG
Kiesweg 2, 97877 Wertheim, www.k-m.de
11903-000-55 Rev1a 03-79-195-00 5/21

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals