K M 19611 Adapter Stand Instruction Manual

June 17, 2024
K M

K M logo 19611 Adapter Stand
Instruction ManualK M 19611 Adapter Stand

19611 Adapter

19611 Adapter Stand

INTENDED USE:
– The adapter allows the mounting of selected screens
– or speakers on stands with ø 35 mm extension tube
FEATURES & CAPABILITIES
– max. load capacity: 25 kg
– professional quality, excellent finish
– Orientation: rotatable 360°.
– Hole patterns for mounting the loads:
– 1. for direct mounting: 70 mm-M6 (3.a)
– 2. per loudspeaker adapter plates K&M-No. 24352 to 24359 (3.b)
– 3. per VESA adapter plates K&M-No. 19615, 19616, 19617, 19618 (3.b)
– Data: Weight 0.5 kg, insertion depth: 80 mm for ø 35 mm
Thank you for choosing this product. Please read and follow these instructions carefully before installation and use. They inform you about all important steps regarding assembly and handling. We recommend that you keep them for future reference.

SAFETY INSTRUCTIONS

ADAPTER 19611
– Max. load: 25 kg, subject to the maximum load capacity of the stand.
– Subject the product to a visual inspection: damaged parts must not be
– used and must either be replaced or repaired.
– Install only suitable screens or speakers. Pay attention to:
– connecting dimensions, size, weight.
– The screw connections between the load, the stand adapter and any
– adapter plates must be firmly tightened; this condition must be checked
– regularly.
– To prevent unintentional rotation of the adapter (and the load), the desired
– position should be fixed by tightening the clamping screw a firmly but not
– overtight. Hand force is enough.
– Protect installation from moisture, humidity, wind loads, etc.
– The safety instructions for the stand must be observed.

INSTALLATION INSTRUCTIONS

  1. COMPONENTS
    The bracket is already completely pre-assembled.
    First of all, a visual inspection must be carried out to determine, as far as recognizable, all parts are present and in order:
    a Clamping screw M8 x 16/33 mm,
    b Adapter, consisting of:
    b.1 Mounting rail (70 mm-M6)
    b.2 Slip-on bushing (für ø 35 mm, 80 mm deep)
    b.3 Threaded eye M8K M 19611 Adapter Stand -
COMPONENTS

  2. MOUNTING ON THE STAND
    2.1 Turn back clamping screw a until the thread no longer
    2.1 protrudes into the inside of the slip-on bushing b.1.
    2.2 Slide the slip-on bushing over the extension tube
    2.2 of the stand as far as it will go (80 mm deep).
    2.3 Align the stand adapter 5 and secure
    2.3 position by tightening the clamping screw a.K M 19611 Adapter Stand -
THE STAND

  3. MOUNTING THE LOAD
    3.a DIRECT MOUNTING – WITHOUT ADAPTER PLATE
    3.a.1 Conditions:
    3.a.1 The screen or the speaker must have two threaded
    3.a.1 sockets, with a:
    3.a.1 – vertical distance of 70 mm
    3.a.1 – the size M4, M5, M6 or 1/4″
    3.a.1 Appropriate screws (not included in the scope of
    3.a.1 delivery) are now screwed in until a distance of approx.
    3.a.1 4 mm remains between the screw head (or washer)
    3.a.1 and the bearing load.
    3.a.2 Now hook the screw fitting into the mounting rail b.1.
    3.a.3 The screws are tightened with a wrench, which is
    3.a.3 made possible by the holes on the back of the slip-onK M 19611 Adapter
Stand - THE STAND1 3.a.3 sleeve.
    3.b INDIRECT MOUNTING – WITH ADAPTER PLATE
    3.b.1 Load capacities:
    3.b.1.1 LOUDSPEAKERS
    3.b.1.1 Adapter plates: 24352, -54, -56, -57. -58, -59.
    3.b.1.1 – Included screws: 2x M6 x 14 mm and washers
    3.b.1.2 SCREENS
    3.b.1.2 Adapter plates 19615 (■75/100), 19616 (100/200)5. ALIGNMENT 360° steplessly rotatable
    5.1 Loosen clamping screw a slightly
    5.2 Hold the load and turn it into the desired direction
    5.3 Retighten the clamping screw
    3.b.1.2 – Included screws: 4x M4 x 14 mm and washers
    3.b.1.2 Adapter plates 19617 (■200), 19618 (■200/400)
    3.b.1.2 – Included screws: 4x M6 x 16 mm and washers/Iso discs;
    5. ALIGNMENT 360° steplessly rotatable
    5.1 Loosen clamping screw a slightly
    5.2 Hold the load and turn it into the desired direction
    5.3 Retighten the clamping screw
    3.b.1.2 – 4x M8 x 20 mm and washers/Iso discs
    3.b.2 Each of the above adapter plates (24352ff, 19615 ff)
    3.b.2 has two M6 threaded bolts. The enclosed flange nuts
    3.b.2 are screwed onto these (keep a distance of 4 mm).
    3.b.3 These nuts are now hooked into the mounting rail.
    3.b.4 Tighten flange nuts with socket wrench SW10 (10 Nm).

  4. SETTINGS
    4. VERTICAL POSITION OF THE LOAD
    A tilt adjustment was deliberately omitted here.
    ADVANTAGE:
    As a result, the distance between the support tube and the load could be minimized due to the design, which has a highly positive effect on the stability (see chapter 7) of the installation.
    NOTE:
    If a tilt adjustment is desired, please refer to our product 19610-000-55 adapter.
    VERTICAL POSITION  OF THE LOAD

  5. ALIGNMENT 360° sleeplessly rotatable
    5.1 Loosen clamping screw a slightly
    5.2 Hold the load and turn it into the desired direction
    5.3 Retighten the clamping screw

  6. SUITABLE K &M STANDS
    6.1 Basically only stands with extension tube ø 35 mm
    6.2 This includes following models from the K&M range:
    6.2 – Speaker stands: 19500, 213, 21302, 21435, 21436,
    6.2 – Speaker stands: 21439, 21449, 21450, 21454, 21459,
    6.2 – Speaker stands: 21460, 21467, 21471, 21472, 26733,
    6.2 – Speaker stands: 26735, 26737, 26750
    6.2 – Lighting stands: 24610, 24624, 24630, 24645
    6.3 The stand must be set up in accordance with these
    6.3 instructions and the safety instructions

  7. STABILITY
    7.1 The complete INSTALLATION (= combination of base,
    7.1 stand, stand adapter and load capacity) must have
    7.1 SUFFICIENT STAND SECURITY.
    7.1 Important influencing factors are:K M 19611 Adapter Stand -
STABILITY7.1.a UNDERGROUND
    7.1.a.1 – must be level and loadbearing;
    7.1.a.2 – sloping surfaces are a hazard
    7.1.b STAND
    7.1.b – the stand used (extension ø 35 mm) must be able
    7.1.b- to safely support the weight of the complete load.
    7.1.b- Attention must be paid to the following:
    7.1.b.1 – the indicated maximum load capacity of the stand
    7.1.b.1 – (which almost always refers to centric loads) must
    7.1.b.1 – not be exceeded
    7.1.b.2 – the stability of the stand depends on the design, the
    7.1.b.2 – choice of materials, the weight and the size ratio of
    7.1.b.2 – the base to the height (the larger the base circle,
    7.1.b.2 – the better)
    7.1.c LOAD
    7.1.c.1 – max. 25 kg on the side of the adapter 19611
    7.1.c.2 – in principle, a centric stand load is ideal, BUT
    7.1.c.2 – the 19611 adapter ALWAYS keeps the load
    7.1.c.2 – OFF CENTRE (distance X)
    7.1.c.3 – For this reason, we always recommend placing
    7.1.c.3 – the load directly above one of the usually three
    7.1.c.3 – feet (depending on the type of stand)
    7.1.d EXTERNAL PROVISIONS
    7.1.d – Possible lateral forces must be prevented
    7.1.d – (examples: wind, shocks, pulling the stand around)
    7.2 5°-KIPPTEST (according to DGUV regulations 17 and 18) is recommended if there is any doubt about the stability
    TEST CONDITIONS
    The installation (deliberately set unfavorably, i.e. maximum height, load between two feet) must not tip over on a plane inclined by 5°.
    WARNING
    When carrying out this test, safety must be ensured: timely interception of the stand. Barriers, safety ropes etc.
    If necessary, call in qualified personnel.
    NOTE
    The 5° tilt test indicates how well the installation resists lateral forces (wind, shocks). Its existence does NOT mean that the installation is allowed to operate on an incline of up to 5°. Rather, this only applies to flat surfaces.7.3 MEASURES to improve stability:
    – Ensure a level and stable base 7.1.a.1
    – Use a suitable stand 7.1.b
    – Always place the load directly above one
    – of the stand feet
    – Reduce stand height
    – Reduce the weight of the load
    – Weigh down/fix the base
    – Fix with tensioning ropes
    Basically, the stand should not risk tipping over – even if the stand adapter 19611 has the most adverse setting

MAINTENANCE

– Gentle handling preserves the function, the load capacity
– and the longevity
– Periodic actuation of moving parts maintains their mobility
– Maintenance work should only be carried out in an unloaded
– condition
– Damaged parts must not be reused, they must be replaced
– or repaired
– Dirt, moisture and any corrosion must be removed
– Use a slightly damp cloth and non-abrasive cleaning agent
– for cleaning and care.

FAULT-FINDING (F) and REPAIR (R)
F: Stand wobbles R: Check stand for stability
R: Are the screw connections on the stand
F: Stative wicket R: tightened correctly?
F: Stand adapter R: Is the sleeve b seated on the stand as far
F: wobbles:
R: as it will go?
R: Check clamping screw a and
R: clamping lever c for tightness.
F: Load wobbles: R: Do the connection dimensions of the load
R: capacity match the stand adapter?
R: The mounting rail b.1 is suitable for M6-70 mm,
R: therefore make sure that the load-bearing capacity
R: or adapter plate is suitable and correctly placed.
R: Check the tightness of the screw connection
R: with the stand adapter.

DIMENSIONS

TECHNICAL DATEN

Material| Receptive sleeve, mounting rail: steel, powdered, black Thread, rivet: galvanised steel Clamping handle: plastic (PA)
---|---
Load| Screens, loudspeakers with suitable connection dimensions
Load capacity| max. 25 kg / lower loads when stand is insecure
Dimensions| Slip-on sleeve for tube-ø 35 mm, mounting hole pattern: M6 x 70 mm
Outer dimensions: 205/212 x 40/54 x 80 mm, net weight: 0.5 kg
Carton| inside 258 x 63 x 81 mm, 0.1 kg

K M logoKÖNIG & MEYER GmbH & Co. KG
Kiese 2, 97877 Wertheim, www.k-m.de
19611-000-55 Rev.01 03-80-961-00 7/23